100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

General Knowledge for Fire Safety Director Exam Questions and Answers

Puntuación
-
Vendido
-
Páginas
17
Grado
A+
Subido en
26-11-2024
Escrito en
2024/2025

General Knowledge for Fire Safety Director Exam Questions and Answers

Institución
General Knowledge For Fire Safety Director
Grado
General Knowledge for Fire Safety Director










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
General Knowledge for Fire Safety Director
Grado
General Knowledge for Fire Safety Director

Información del documento

Subido en
26 de noviembre de 2024
Número de páginas
17
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

General Knowledge for Fire Safety Director
Exam Questions and Answers
Which is NOT a part of the monthly visual inspection of the standpipe? - -
Conduct a hydrostatic test of the standpipe system

- What is the main purpose of the roof manifold? - -Firefighting and testing
of the standpipe system

- Which best describes the primary purpose of the upper check valve located
under a roof water storage tank? - -To stop water from going into the tank

- If water is flowing from a ball drip connection, it might mean? - -The lower
check valve may be defective

- What is the purpose of the OS&Y valve? - -To stop or regulate the flow of
water through the system

- "Automatic dry" sprinkler systems are filled with? - -Air under pressure

- Standpipe system supply valves under normal conditions are kept? - -
Opened and chained

- The color of the FDC caps for a non-automatic system are? - -Aluminum

- How often will a standpipe system (office building) be required to perform
a hydrostatic test to demonstrate its suitability for fire department use?
(minimum) - -Five years

- Sprinkler heads that get paint on them - -Must be replaced with a new
head

- Which of the following is NOT an example of a supervisory device? - -Fire
safety evacuation plan

- During the monthly visual inspection of the standpipe system, the
Certificate of Fitness holder notices that the gravity tank is empty. Who
should be notified? - -The manager of the building, and the FDNY Borough
Dispatcher

- Which one of the following is NOT a typical primary source of water for a
standpipe system? - -Siamese connection (FDC)

, - The water valve that controls water flow in a sprinkler system has a wheel
and an exposed stem (if in the open position). This valve is called: - -The OS
& Y valve

- A Fire Department Connection (FDC) that supplies water to standpipe
system only would be colored: - -Red

- Standpipe systems are generally required in buildings which are more than
__________ feet height - -75

- In a fully sprinklered building, the number of extra sprinkler heads required
to be kept at the main water control valve is: - -At least 6

- It is an effective means of suppressing fire, and at the same time transmits
an alarm to the Fire Department. This statement describes: - -An automatic
sprinkler system

- With regard to the height of stock in a sprinklered storeroom, it is most
correct to state that the stock must be placed: - -NOT closer than 18" to the
sprinkler piping

- Who is required to designate a impairment coordinator to be responsible
for complying with the Out-of-service sprinkler system requirements of the
Fire Code? - -The Building Owner

- The Fire Brigade duties include: - -. Contact FSD for the fire details darning
evacuation
. Initially report to floor below the fire, and assist in
evacuation
. Investigate the cause for the alarm and attempting to
control spread fire

- A CoF is required for a FSD for a building classified in the Building Code as
occupancy group B, occupied by: - -- More than 100 persons above the
street level
- More than 100 persons below the street level
- More than a total of 500 persons in the entire building

- The FSD must make sure that the hallways and stairways are: - -- Properly
Illuminated
- Free from garbage accumulation
- Free from obstruction

- As a general rule, during a fire, most hazardous locations in a high-rise
building would be: - -The fire floor and the floor above the alarm

, - Evacuation to ____________ or more levels below the fire is generally
adequate: - -3

- Fire Warden an a Deputy Fire Warden: - -- Fire prevention activities,
provisions for persons w/ special needs in a fire
- If directed, conduct evacuation of assigned floor
- Put on identifying apparel or item and account for employees, provide for
those w/ special needs, knowing the exits and egress keeping them clear.

- When is acceptable for a Building Evacuation Supervisor to be on duty in
an office building (Class B) - -When there are fewer than 100 persons in the
building

- Upon notification of an alarm condition or other emergency, the FSD must
report to: - -The Fire Command Station

- Which of the following is NOT a duty of the FSD? - -Respond to the fire
floor during an alarm condition to investigate

- The person responsible by law for complying with Fire Safety Laws is: - -
The owner of the building

- What does R.C.N.Y. stand for: - -The Rules of the City of New York

- To became FSD you must: - -- You need to pass the finals in class
- You need to pass a 100 question test at the Fire Department
- You need to pass an Onsite test at your job

- As a general rule, during fire the most hazardous locations in the building
would be: - -The fire floor and the floor above the alarm

- When evacuation is taking place during emergency all re-entry doors
should be OPEN IN THE STAIRWELL on approximately every ________ floors - -
4

- The best way to pass thos class is to: - -Take notes, high-lighting your
book and study at least one 2-3 hours a week

- What is the meaning for Class B and class R-1, building - -the Code for
office Buildings and Hotels

- When is it a good time to evacuate up in a fire? - -Never

- The FSD position was started: - -Local Law #5 in 1973 by the City of New
York due to out of control fires
$12.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Thumbnail
Package deal
Fire Safety Exams
-
11 2024
$ 128.39 Más información

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
AccurateScores Not yet listed
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
542
Miembro desde
3 año
Número de seguidores
336
Documentos
15259
Última venta
1 semana hace

3.7

113 reseñas

5
51
4
18
3
18
2
11
1
15

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes