• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 2 fuera de 15 páginas
Examen

S12 sprinkler test Study Guide Solutions

Document preview thumbnail
Vista previa 2 fuera de 15 páginas

S12 sprinkler test Study Guide Solutions fire department connection - ANSWER-normally on exterior of building... FDNY can pump supplemental water into the sprinkler system, standpipe, or other system furnishing water for fire extinguishment to supplement existing water supplies. system control valve - ANSWER-valve controlling flow to water-based fire protection systems. fire command center - ANSWER-Designated room or area in a structure where the status of the fire detection, alarm, and protection systems is displayed and the systems can be manually controlled. Fire pump, automatic standpipe. - ANSWER-A fire pump located at or below street level that supplies the lower 300 feet (91.4 m) of a standpipe system or a combined standpipe and sprinkler system. tags - ANSWER-on closed section valves serving affected areas: area affected, brief description, occupancy classification, c of f number, estimated time until operational Green tag - ANSWER-no impairment found in entire system- main control valve Copyright ©SOPHIABENNETT 2025 ACADEMIC YEARALL RIGHTS RESERVED. Page 2/15 red tag - ANSWER-place on main control valve if FULLY out of service... put sprinkler company name, date of removal from service and anticipated time to operational blue disk - ANSWER-partially out of service- on all fire department connections water storage tank - ANSWER-Collects cooled water OS & Y valve - ANSWER-indicating type of control valve used for fire sprinkler system deluge valve - ANSWER-water supply control valve intended to be operated by actuation of an automatic detection system that is installed in the same area as the discharge devices. INTENDED USE IS MANUAL AND AUTO deluge sprinkler system - ANSWER-employing open sprinklers that are attached to a piping system that is connected to a water supply through a valve that is opened by the operation of a detection system installed in the same areas as the sprinklers. WHEN IT OPENS, water flows into the piping system and discharges from all sprinklers attached. Early suppresion fast response sprinklers - ANSWER-fast response sprinkler that is listed for its capability to provide fire suppression of specific high challenge fire hazards extra large orifice sprinklers - ANSWER-= or 1 inch less pressure to achieve a given discharge density Copyright ©SOPHIABENNETT 2025 ACADEMIC YEARALL RIGHTS RESERVED. Page 3/15 extended coverage sprinkler - ANSWER-400 max square feet discharge 20 foot by 20 foot spacing between sprinklers fire pump - ANSWER-a provider of liquid flow and pressure dedicated to fire protection. A fire pump is a part of a fire sprinklers system water supply and can be powered by electric, diesel or steam. connected to public water source or tank. provides higher pressure to sprinkler system Glass bulb sprinkler - ANSWER-operated by heat breaking a glass bulb filled with a non freezing liquid with diameters that vary form 3 mm for quick response to 5 mm for standard response hose valve - ANSWER-valve to additional hose connection hydraulic placard - ANSWER-sign attached to a hydraulically calculated sprinkler system indicating the design density, required gallons per minute and pressure for the system to operate properly hydraulically calculated systems - ANSWER-method of sizing auto sprinkler piping using a prescribed amount of water to be distributed over a specific area. impairment coordinator - ANSWER-in charge of safety during out of service systems Copyright ©SOPHIABENNETT 2025 ACADEMIC YEARALL RIGHTS RESERVED. Page 4/15 intermediate level sprinkler - ANSWER-sprinkler equipped with integral shields to protect the operating elemtn form discharge from sprinklers installed at higher elevations large orifice sprinkler - ANSWER-sprinkler head with orifice size equal or greater than 3/4 and less than 1 inch listed device - ANSWER-A fire protection component that has been tested to perform under parameters specified for its use by a nationally recognized testing agency. Underwriter's Laboratory (UL) and Factory Mutual (FM) are the two most common. Master Pressure Reducing Valve - ANSWER-A pressure reducing valve installed to regulate pressures in an entire fire protection system and/or standpipe system zone. Main Drain - ANSWER-The primary drain connection located on the system riser and also utilized as a flow test connection. Microbiologically Influenced Corrosion (MIC) - ANSWER-Corrosion caused by the presence of microbes in the water supply that over time attack the interior of metallic piping and cause leaks, pitting, and blockages. Old-Style/Conventional Sprinkler - ANSWER-A sprinkler that di

Vista previa del contenido

S12 sprinkler test Study Guide
Solutions

fire department connection - ANSWER✔✔-normally on exterior of building... FDNY

can pump supplemental water into the sprinkler system, standpipe, or other system

furnishing water for fire extinguishment to supplement existing water supplies.


system control valve - ANSWER✔✔-valve controlling flow to water-based fire

protection systems.


fire command center - ANSWER✔✔-Designated room or area in a structure where the

status of the fire detection, alarm, and protection systems is displayed and the systems

can be manually controlled.


Fire pump, automatic standpipe. - ANSWER✔✔-A fire pump located at or below street

level that supplies the lower 300 feet (91.4 m) of a standpipe system or a combined

standpipe and sprinkler system.


tags - ANSWER✔✔-on closed section valves serving affected areas: area affected, brief

description, occupancy classification, c of f number, estimated time until operational


Green tag - ANSWER✔✔-no impairment found in entire system- main control valve




Copyright ©SOPHIABENNETT 2025 ACADEMIC YEARALL RIGHTS RESERVED. Page 1/15

, red tag - ANSWER✔✔-place on main control valve if FULLY out of service... put

sprinkler company name, date of removal from service and anticipated time to

operational


blue disk - ANSWER✔✔-partially out of service- on all fire department connections


water storage tank - ANSWER✔✔-Collects cooled water


OS & Y valve - ANSWER✔✔-indicating type of control valve used for fire sprinkler

system


deluge valve - ANSWER✔✔-water supply control valve intended to be operated by

actuation of an automatic detection system that is installed in the same area as the

discharge devices. INTENDED USE IS MANUAL AND AUTO


deluge sprinkler system - ANSWER✔✔-employing open sprinklers that are attached to

a piping system that is connected to a water supply through a valve that is opened by

the operation of a detection system installed in the same areas as the sprinklers. WHEN

IT OPENS, water flows into the piping system and discharges from all sprinklers

attached.


Early suppresion fast response sprinklers - ANSWER✔✔-fast response sprinkler that is

listed for its capability to provide fire suppression of specific high challenge fire hazards


extra large orifice sprinklers - ANSWER✔✔-= or > 1 inch less pressure to achieve a

given discharge density


Copyright ©SOPHIABENNETT 2025 ACADEMIC YEARALL RIGHTS RESERVED. Page 2/15

Información del documento

Subido en
17 de noviembre de 2024
Número de páginas
15
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$12.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
SophiaBennett
3.6
(29)
Vendido
159
Seguidores
5
Artículos
9084
Última venta
1 mes hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes