Oil Burner License Exam 2023 Questions and Answers What is the first thing a tech should do when arriving at a no combustion call? - AnswerAsk how many times the customer reset the unit. .What is the best long term solution for preventing a clogged nozzle? - Answer-Remove any underground storage tanks. -Install a quality oil filter. -Cut the suction line 10" above the tank outlet to prevent sludge. .Hot water and steam valves are interchangeable. - AnswerFalse .When in the presence of a flame, a cad cell normally reads.. - Answer300-1000 ohms .If a pump is used to bring oil to a level higher than the tank, an oil safety valve is required. - AnswerTrue .On a call where a hydronic heat system is putting out too much heat on the stack, the issue may be.. - Answer-Too much draft. -Not enough combustion air in the equipment room. -Air leakage into chamber. .A high CO2 reading is caused by.. - AnswerIncomplete combustion .An often overlooked cause of a high CO2 reading is.. - AnswerNot enough combustion air in the equipment room. .When multiple pumps are wired together in a heating system, they should be wired in.. - Answerparallel .In a series circuit.. - AnswerCurrent has one path. .When 2 burners are connected to the same chimney.. - AnswerSufficient draft must be obtained to operate both units. .The ignition transformer is located.. - AnswerIn the primary control. .When safeties are wired in series one safety will affect the operation of the others. - AnswerTrue .A stack switch is no longer allowed to be installed or replaced because.. - AnswerIt's safety cutout time is higher than what is now required. .What is a power venter and what does it do? - AnswerAn electrical device that sends fluid gases into the chimney connector. .A burner in a confined space using 1 GPH of #2 fuel oil requires what size permanent opening for combustion air? - Answer140" .The difference between an adjustable flame retention burner and a fixed flame retention burner is? - AnswerAir inlets can be adjusted Ignitor position can be adjusted Fuel can be adjusted .Oil tank design, construction, installation and testing shall be in accordance with.. - Answer527 CMR 9.0 .Heat is a form of.. - AnswerEnergy .If a burner is operational but the circulator pump isn't running.. - AnswerThe pump relay is not working correctly .A method of dealing with low viscosity/cold temps with #2 oil? - AnswerIncrease pump pressure/ decrease nozzle size .What is needed at the outlet of an oil tank? - AnswerThermal safety valve .Where do you obtain an installation permit for oil burners? - AnswerFire Dept .How many Btu's approximately in 1 gal of #2 fuel oil? - Answer140,000 btu's .Solid state ignition is superior to spark because - AnswerIt is not affected by reduced voltage .What is an installation? - AnswerThe complete setting in place, ready for operation, of an oil burner appliance together with its accessories and equipment. .How far must a power vent terminate from an opening or window? - Answer4' .A pump in a one pipe system that is full of air can be self purged. - AnswerFalse .List the minimum size of an oil supply line. - Answer3/8" .A material with electrons so loose it allows voltage to pass with little or no resistance.. - AnswerIs a conductor .If a high limit goes off, what does a low water switch do? - AnswerMaintains water temperature .What is flashpoint an indicator of? - AnswerMinimum temperature oil will ignite but not continue to burn. .What travels on the inside of the wire? - AnswerVolts .What does readily accessible mean pertaining to oil burning equipment? - AnswerCapable of being reached easily and quickly for operation, maintenance or inspection. .What is the minimum vent pipe on an oil tank? - Answer1 1/4" .What causes corrosion on a flue pipe? - AnswerWhen the flue pipe is operating below the dew point temperature. .What are the methods to prevent oil waxing? - AnswerPut additives in the fuel. Add an oil line heater. Cut with #1 fuel or kerosene. .What is the maximum tank size allowed inside unenclosed? - Answer660 gal .What is the purpose of a delayed oil valve? - AnswerAllows time for the oil pump to get up to speed. Delays oil flow to the nozzle. .On a call where a hydronic heat system is putting out too much heat, the issue could be? - AnswerA shorted out thermostat. .When measuring a cad cell with the burner running and the ff terminals jumped out, what should the cad cell reading be? - Answer1600 ohms .What are the possible causes of soot at or near the power venter? - AnswerIncomplete combustion .What is a possible side effect of air in a nozzle line? - AnswerSoot .What is the cause if the cad cell is tripped on safety? - AnswerDirty cad cell Faulty cad cell No flame present .If a boiler is running but the water temperature is low? - AnswerUndersized nozzle

Show more Read less
Institution
Oil Burner License
Module
Oil Burner License










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Oil Burner License
Module
Oil Burner License

Document information

Uploaded on
November 17, 2024
Number of pages
18
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Oil Burner License Exam 2023 Questions and Answers

What is the first thing a tech should do when arriving at a no combustion call? -
AnswerAsk how many times the customer reset the unit.

.What is the best long term solution for preventing a clogged nozzle? - Answer-Remove
any underground storage tanks.
-Install a quality oil filter.
-Cut the suction line 10" above the tank outlet to prevent sludge.

.Hot water and steam valves are interchangeable. - AnswerFalse

.When in the presence of a flame, a cad cell normally reads.. - Answer300-1000 ohms

.If a pump is used to bring oil to a level higher than the tank, an oil safety valve is
required. - AnswerTrue

.On a call where a hydronic heat system is putting out too much heat on the stack, the
issue may be.. - Answer-Too much draft.
-Not enough combustion air in the equipment room.
-Air leakage into chamber.

.A high CO2 reading is caused by.. - AnswerIncomplete combustion

.An often overlooked cause of a high CO2 reading is.. - AnswerNot enough combustion
air in the equipment room.

.When multiple pumps are wired together in a heating system, they should be wired in..
- Answerparallel

.In a series circuit.. - AnswerCurrent has one path.

.When 2 burners are connected to the same chimney.. - AnswerSufficient draft must be
obtained to operate both units.

.The ignition transformer is located.. - AnswerIn the primary control.

.When safeties are wired in series one safety will affect the operation of the others. -
AnswerTrue

.A stack switch is no longer allowed to be installed or replaced because.. - AnswerIt's
safety cutout time is higher than what is now required.

.What is a power venter and what does it do? - AnswerAn electrical device that sends
fluid gases into the chimney connector.

,.A burner in a confined space using 1 GPH of #2 fuel oil requires what size permanent
opening for combustion air? - Answer140"

.The difference between an adjustable flame retention burner and a fixed flame
retention burner is? - AnswerAir inlets can be adjusted

Ignitor position can be adjusted

Fuel can be adjusted

.Oil tank design, construction, installation and testing shall be in accordance with.. -
Answer527 CMR 9.0

.Heat is a form of.. - AnswerEnergy

.If a burner is operational but the circulator pump isn't running.. - AnswerThe pump relay
is not working correctly

.A method of dealing with low viscosity/cold temps with #2 oil? - AnswerIncrease pump
pressure/ decrease nozzle size

.What is needed at the outlet of an oil tank? - AnswerThermal safety valve

.Where do you obtain an installation permit for oil burners? - AnswerFire Dept

.How many Btu's approximately in 1 gal of #2 fuel oil? - Answer140,000 btu's

.Solid state ignition is superior to spark because - AnswerIt is not affected by reduced
voltage

.What is an installation? - AnswerThe complete setting in place, ready for operation, of
an oil burner appliance together with its accessories and equipment.

.How far must a power vent terminate from an opening or window? - Answer4'

.A pump in a one pipe system that is full of air can be self purged. - AnswerFalse

.List the minimum size of an oil supply line. - Answer3/8"

.A material with electrons so loose it allows voltage to pass with little or no resistance.. -
AnswerIs a conductor

.If a high limit goes off, what does a low water switch do? - AnswerMaintains water
temperature

, .What is flashpoint an indicator of? - AnswerMinimum temperature oil will ignite but not
continue to burn.

.What travels on the inside of the wire? - AnswerVolts

.What does readily accessible mean pertaining to oil burning equipment? -
AnswerCapable of being reached easily and quickly for operation, maintenance or
inspection.

.What is the minimum vent pipe on an oil tank? - Answer1 1/4"

.What causes corrosion on a flue pipe? - AnswerWhen the flue pipe is operating below
the dew point temperature.

.What are the methods to prevent oil waxing? - AnswerPut additives in the fuel.

Add an oil line heater.

Cut with #1 fuel or kerosene.

.What is the maximum tank size allowed inside unenclosed? - Answer660 gal

.What is the purpose of a delayed oil valve? - AnswerAllows time for the oil pump to get
up to speed.

Delays oil flow to the nozzle.

.On a call where a hydronic heat system is putting out too much heat, the issue could
be? - AnswerA shorted out thermostat.

.When measuring a cad cell with the burner running and the ff terminals jumped out,
what should the cad cell reading be? - Answer1600 ohms

.What are the possible causes of soot at or near the power venter? - AnswerIncomplete
combustion

.What is a possible side effect of air in a nozzle line? - AnswerSoot

.What is the cause if the cad cell is tripped on safety? - AnswerDirty cad cell

Faulty cad cell

No flame present

.If a boiler is running but the water temperature is low? - AnswerUndersized nozzle
$12.49
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
stuviafinestgrades

Get to know the seller

Seller avatar
stuviafinestgrades University of Chicago
View profile
Follow You need to be logged in order to follow users or courses
Sold
0
Member since
1 year
Number of followers
1
Documents
65
Last sold
-
STUVIAFINESTGRADES

EXCELLENT HOMEWORK HELP AND TUTORING ,ALL KIND OF QUIZ AND EXAMS WITH GUARANTEE OF A Am an expert on major courses especially; psychology,Nursing, Human resource Management and Mathemtics Assisting students with quality work is my first priority. I ensure scholarly standards in my documents and that's why i'm one of the BEST GOLD RATED TUTORS in STUVIA. I assure a GOOD GRADE if you will use my work.

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Frequently asked questions