Where do you file a permit for work to be done in buildings owned or used by the State of Mass ? - answer-State Inspector When pressure testing a system over 1 million btu , which doesn't apply ? - answer-Test 1 hour for each 200 ' of developed length When a vent on a regulator , what is the horizontal distance from the discharge of the vent to an opening located below ? - answer-3 feet How many cycles do you need to keep continuing education certificates ? - answer-3 On an LP - Gas system , what is considered to be the " Point of Delivery " ? - answer-Outlet of 1st stage How fast does a spill switch need to work ? - answer-30 seconds If the firing rate in a combustion chamber exceeds 1,000,000 BTU , but less than 5,000,000 , what is required ? - answer-2 shut offs in series , or one with overtravel interlock When using gas pressure boosters , which of the following apply ? - answer-All must meet product - acceptance requirements The serving gas supplier has provided written authorization Gas pressure boosters shall be located in well - ventilated spaces , and readily accessible What percentage of vent height can the length of a single - walled vent connector be ? - answer-75 % What percentage of vent height can the length of Type B , double - walled vent connector be ? - answer-100 % What is the max pressure for natural gas in a house ? - answer-14 " WC Within how many feet of an appliance does the shut off need to be ? - answer-6' How far does a roof hatch need to be from the edge of a roof to not need guardrails ? - answer-6' What is the maximum pressure allowed for CSST . - answer-14 " WC If the maximum firing rate per combustion chamber is ____ , BTU or greater ,

Vista previa del contenido

LP INSTALLERS PRACTICE EXAM
Where do you file a permit for work to be done in buildings owned or used by
the State of Mass ? - answer-State Inspector

When pressure testing a system over 1 million btu , which doesn't apply ? -
answer-Test 1 hour for each 200 ' of developed length

When a vent on a regulator , what is the horizontal distance from the
discharge of the vent to an opening located below ? - answer-3 feet

How many cycles do you need to keep continuing education certificates ? -
answer-3

On an LP - Gas system , what is considered to be the " Point of Delivery " ? -
answer-Outlet of 1st stage

How fast does a spill switch need to work ? - answer-30 seconds

If the firing rate in a combustion chamber exceeds 1,000,000 BTU , but less
than 5,000,000 , what is required ? - answer-2 shut offs in series , or one
with overtravel interlock

When using gas pressure boosters , which of the following apply ? - answer-
All must meet product - acceptance requirements The serving gas supplier
has provided written authorization Gas pressure boosters shall be located in
well - ventilated spaces , and readily accessible

What percentage of vent height can the length of a single - walled vent
connector be ? - answer-75 %

What percentage of vent height can the length of Type B , double - walled
vent connector be ? - answer-100 %

What is the max pressure for natural gas in a house ? - answer-14 " WC

Within how many feet of an appliance does the shut off need to be ? -
answer-6'

How far does a roof hatch need to be from the edge of a roof to not need
guardrails ? - answer-6'

What is the maximum pressure allowed for CSST . - answer-14 " WC

, If the maximum firing rate per combustion chamber is ____ , BTU or greater ,
gas pressure supervision provided by listed pressure switches or
combination high / low switch , interlocked to accomplish safety shutdown in
event of either high or low pressure . - answer-1,000,000

Max spacing for support for CSST on a rooftop is every . - answer-Blocks used
for Support 48 "

A vacuum is considered to be any pressure that is - answer-Less than
atmospheric pressure (14.7 psi)

If an UG gas line runs under a building , what is required ? - answer-Conduit
must terminate outside building ,Sleeved in same material as pipe Terminate
4 ' above grade

Apprentice plumber , apprentice gas fitter , or MA Lic . LP Installer - answer-
Must show license when asked by the Inspector

What is not an acceptable material for LPG piping - answer-Butylenes

How far above a forced air inlet must a vent be terminated it within 10 ft
horizontally ? - answer-3 '

Can you vent into a mechanical vent under a positive pressure ? - answer-no

What is not an acceptable material for LPG piping ? - answer-Galvanized

How far above the floor must you have an opening for make - up air ? -
answer-< 12 "

How far can a relief discharge from a rigid LP gas regulator from a Building
Opening below discharge ? - answer-3'

Which method is not an approved method of connecting pipe ? - answer-
Soldered

Vent termination above a public walkway needs to terminate how high above
grade ? - answer-7 '

Decorative gas appliance in a vented fireplace must have ? - answer-Screen
door

When opening / adding to a gas system who must be notified prior to
commencing work ? - answer-Local Inspector

Información del documento

Subido en
11 de noviembre de 2024
Número de páginas
8
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$8.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
TOPDOCTOR
5.0
(1)
Vendido
10
Seguidores
5
Artículos
3387
Última venta
1 año hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes