OIL BURNER LICENSE LATEST
VERSIONS 2024-2025 CONTAINS
QUESTIONS AND CORRECT
UPDATED ANSWERS GRADED
A++++

Oil Burner License
What is the first thing a tech should do when arriving at a no
combustion call?
- CORRECT ANSWERS - Ask how many times the customer reset
the unit.


What is the best long term solution for preventing a clogged nozzle?
- CORRECT ANSWERS - -Remove any underground storage tanks.
-Install a quality oil filter.
-Cut the suction line 10" above the tank outlet to prevent sludge.


Hot water and steam valves are interchangeable.
- CORRECT ANSWERS - False


When in the presence of a flame, a cad cell normally reads..
- CORRECT ANSWERS - 300-1000 ohms


If a pump is used to bring oil to a level higher than the tank, an oil
safety valve is required.

,- CORRECT ANSWERS - True


On a call where a hydronic heat system is putting out too much heat
on the stack, the issue may be..
- CORRECT ANSWERS - -Too much draft.
-Not enough combustion air in the equipment room.
-Air leakage into chamber.


A high CO2 reading is caused by..
- CORRECT ANSWERS - Incomplete combustion


An often overlooked cause of a high CO2 reading is..
- CORRECT ANSWERS - Not enough combustion air in the
equipment room.


When multiple pumps are wired together in a heating system, they
should be wired in..
- CORRECT ANSWERS - parallel


In a series circuit..
- CORRECT ANSWERS - Current has one path.


When 2 burners are connected to the same chimney..
- CORRECT ANSWERS - Sufficient draft must be obtained to
operate both units.

,The ignition transformer is located..
- CORRECT ANSWERS - In the primary control.


When safeties are wired in series one safety will affect the operation
of the others.
- CORRECT ANSWERS - True


A stack switch is no longer allowed to be installed or replaced
because..
- CORRECT ANSWERS - It's safety cutout time is higher than what
is now required.


What is a power venter and what does it do?
- CORRECT ANSWERS - An electrical device that sends fluid gases
into the chimney connector.


A burner in a confined space using 1 GPH of #2 fuel oil requires what
size permanent opening for combustion air?
- CORRECT ANSWERS - 140"


The difference between an adjustable flame retention burner and a
fixed flame retention burner is?
- CORRECT ANSWERS - Air inlets can be adjusted


Ignitor position can be adjusted


Fuel can be adjusted

, Oil tank design, construction, installation and testing shall be in
accordance with..
- CORRECT ANSWERS - 527 CMR 9.0


Heat is a form of..
- CORRECT ANSWERS - Energy


If a burner is operational but the circulator pump isn't running.. -
CORRECT ANSWERS - The pump relay is not working correctly


A method of dealing with low viscosity/cold temps with #2 oil? -
CORRECT ANSWERS - Increase pump pressure/ decrease nozzle
size


What is needed at the outlet of an oil tank? - CORRECT ANSWERS -
Thermal safety valve


Where do you obtain an installation permit for oil burners? -
CORRECT ANSWERS - Fire Dept


How many Btu's approximately in 1 gal of #2 fuel oil? - CORRECT
ANSWERS - 140,000 btu's


Solid state ignition is superior to spark because - CORRECT
ANSWERS - It is not affected by reduced voltage

Escuela, estudio y materia

Institución
Oil burner
Grado
Oil burner

Información del documento

Subido en
10 de noviembre de 2024
Número de páginas
35
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$19.49
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Conoce al vendedor
Seller avatar
ephriterry1227

Conoce al vendedor

Seller avatar
ephriterry1227 Chamberlain College Nursing
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
1
Miembro desde
1 año
Número de seguidores
0
Documentos
96
Última venta
1 año hace
SEND A MESSAGE RIGHT NOW I HELP YOU

As a trusted professional working at ATI and ANCC, I offer authentic exam papers directly sourced from these reputable institutions ,my papers serve as invaluable tools to aid aspiring nurses in their exam preparations. Backed by my experience and expertise, I ensure that each paper is meticulously crafted. SEND A MESSAGE RIGHT NOW I HELP YOU

0.0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes