What is the CMS-adopted NFPA standard for portable fire extinguishers? - ANS NFPA 10 2010 Edition What is the CMS-adopted NFPA National Electric Code? - ANS NFPA 70 2011 Edition What is the CMS-adopted NFPA standard for a health care facilities code? - ANS NFPA 99 2012 Edition What is the title of CMS-adopted NFPA 241? - ANS Standard for Safeguarding Construction, Alteration and Demolition Operations 2009 Edition Where can you find design standards adopted by the majority of states? - ANS Facilities Guidelines Institute (FGI) 2014 Edition What is CMS? - ANS Centers for Medicare and Medicaid Services What does ASHRAE stand for? - ANS American Society of Heating, Refrigerating and Air-Conditioning Engineers What are DNV, The Joint Commission and HFAP? - ANS Accrediting Organizations (AOs) that have deemed authority for CMS. What is an AHJ? - ANS Authority Having Jurisdiction What are the four elements of the Life Safety Code? - ANS Compartmentalization. Detection. Suppression. Egress What are the first components of fire defense in a building design for patients? - ANS The first components of fire defense in a building design for patients are room and corridors.

Vista previa del contenido

CHFM Compliance of Health Care Exam
Questions And Answers


What is the CMS-adopted NFPA standard for portable fire extinguishers? - ANS NFPA 10

2010 Edition

What is the CMS-adopted NFPA National Electric Code? - ANS NFPA 70

2011 Edition

What is the CMS-adopted NFPA standard for a health care facilities code? - ANS NFPA 99

2012 Edition

What is the title of CMS-adopted NFPA 241? - ANS Standard for Safeguarding
Construction, Alteration and Demolition Operations

2009 Edition

Where can you find design standards adopted by the majority of states? - ANS Facilities
Guidelines Institute (FGI)

2014 Edition

What is CMS? - ANS Centers for Medicare and Medicaid Services

What does ASHRAE stand for? - ANS American Society of Heating, Refrigerating and
Air-Conditioning Engineers

What are DNV, The Joint Commission and HFAP? - ANS Accrediting Organizations (AOs)
that have deemed authority for CMS.

What is an AHJ? - ANS Authority Having Jurisdiction

What are the four elements of the Life Safety Code? - ANS Compartmentalization.
Detection.
Suppression.

, Egress

What are the first components of fire defense in a building design for patients? - ANS The
first components of fire defense in a building design for patients are room and corridors.

A space within a building enclosed by smoke barriers on all sides, including top and bottom, is a
. - ANS smoke compartment

What is the maximum smoke compartment size? - ANS 22,500 sq. ft.

Per 2012 Edition of the Life Safety Code

What date was the NFPA 101", Life Safety Code adopted? - ANS July 5, 2016

Every story used by for sleeping for more than 30 patients shall be divided into two smoke
compartments. - ANS inpatients

What is the maximum travel distance for a non-sprinklered building? - ANS The maximum
travel distance for a non-sprinklered building is 150 feet

The maximum travel distance for a sprinklered building is 200 feet

A hospital floor must resist the passage of and . - ANS fire, smoke

Per CMS, what type of door hardware is NOT permitted in health care? - ANS Roller
latches are NOT permitted in health care.

Typical types of occupancies in a health care facility are , and. . - ANS health care,
business, assembly

A separation is typically required between health care and other occupancies. - ANS
2-hour

are provided to subdivide building spaces to restrict the movement of smoke. - ANS Smoke
barriers

What fire rating required for a smoke partition? - ANS None

Corridor walls in non-sprinklered buildings must extend . - ANS Above the ceiling to the
deck above.

Also known an floor-to-deck

The maximum smoke compartment size in new construction is

Información del documento

Subido en
23 de octubre de 2024
Número de páginas
5
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$10.89

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
DocLaura
4.2
(44)
Vendido
161
Seguidores
38
Artículos
6357
Última venta
1 mes hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes