ENGINEER LICENSE TEST
3RD CLASS STATIONARY STEAM ENGINEER LICENSE TEST WITH GUARANTEED
ACCURATE ANSWERS
_________ are necessary for complete combustion - Accurate
Answers✔✔✔ time, temperature, mixture, and atomization
If the steam pressure gauge indicates 200 PSIG, the absolute pressure
is______ - Accurate Answers✔✔✔ 214.7
A boiler is operating at 400 PSI, and the safety valve opens at 410 PSI
and closes at 398 PSI. The blowdown is______ psi - Accurate
Answers✔✔✔ 12
,An oil cooler is commonly used with a(n) ________ when operating in
conjunction with a turbo-generator - Accurate Answers✔✔✔ steam
turbine
A boiler is producing 40,000lb of steam/hr at a pressure of 100 PSI and a
steam temperature of 500 degrees Fahrenheit. The steam produced is
_______ steam - Accurate Answers✔✔✔ superheated
The economizer on a boiler is used to _______ - Accurate
Answers✔✔✔ add heat to the feed water
Blowers are normally used with________ boilers - Accurate
Answers✔✔✔ water tube
Overheating of tubes on a boiler can be caused by________ - Accurate
Answers✔✔✔ scale on tubes
Carbon dioxide in a condensate return system causes_________ -
Accurate Answers✔✔✔ channeling
A ________ pump is a positive displacement pump - Accurate
Answers✔✔✔ reciprocating
A boiler generating 6000 lb of steam/hr produces _______btu/hr -
Accurate Answers✔✔✔ 6,000,000
,A bottom blowdown is performed on a boiler to _____ - Accurate
Answers✔✔✔ discharge sludge and sediment
Water columns are connected to the boiler with a minimum of _______"
pipe - Accurate Answers✔✔✔ 1
The minimum size of a water column blowdown valve is_______". -
Accurate Answers✔✔✔ 3/4
The maximum size bottom blowdown valve on a boiler is_________". -
Accurate Answers✔✔✔ 2 1/2
A ________ allows condensate to pass through, but stops Steam. -
Accurate Answers✔✔✔ a steam trap
When taking over a shift, the first thing to do is check the________ -
Accurate Answers✔✔✔ water level in each boiler
According to the asme code, a high-pressure boiler having more than
500 square feet of heating surface shall have________ - Accurate
Answers✔✔✔ two or more safety valves
The probable cause of an increase in temperature of gases of combustion
at the boiler Outlet is____ - Accurate Answers✔✔✔ dirty heating
services
, Boilers in battery equipped with________ must have two main steam
stop valves and a free-flowing drain between them - Accurate
Answers✔✔✔ manhole openings
In order to be sure the gauge glass is indicating an accurate water level
reading, the stationary engineer should______ - Accurate Answers✔✔✔
blowdown the gauge glass
A continuous blowdown line is located___ - Accurate Answers✔✔✔ in
the Steam and water drum well below the nowl
A temperature reading of 80 degrees Celsius is equal to_________°f -
Accurate Answers✔✔✔ 176
A chimney temperature of 250 degrees Fahrenheit above steam
temperature indicates_______ - Accurate Answers✔✔✔ poor efficiency
A manometer is red in________ - Accurate Answers✔✔✔ inches of
water
The boiling point of water will____ with an increase in pressure -
Accurate Answers✔✔✔ be raised
If a lather is not obtained when performing a soap hardness test, the
water sample is_______ - Accurate Answers✔✔✔ hard