Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Examen

TCEQ IRRIGATION LICENSE STUDY GUIDE questions and answers

Puntuación
-
Vendido
-
Páginas
2
Grado
A+
Subido en
17-10-2024
Escrito en
2024/2025

TCEQ IRRIGATION LICENSE STUDY GUIDE questions and answers Assembly (RPPA) (RPZ) is required when fertilizer injection are being used. Causes backsiphonage?Caused by a negative or Sub-atmospheric pressure. Example-City departments are using fire hydrant or there's a city main line break, or someone sucking liquid from a glass using a straw. Causes of leaking check valveDebris-can enter the valve. (Can use Y strainer to provide a solution.) Definition of high-hazard system?Non-potable water, chemicals, fertilizers Definition of cross-connection?Any actual or potential connection between a potable water supply and any source of contamination or pollution. BPA requirements for fertilizer injection systemReduced Pressure Principle Degree of hazardA measure of the degree of risk or harm to the public's health. General installation requirements of BPADevice must check/pass Back siphonage, Back-pressure, constant pressure, non-health hazard, health hazard. Installation requirements of AVB-Installed 6" above the highest head or outlet in the system. -No Valves -Downstream. -Installed vertically. Installation and inspection requirements for public water system to BPA installation requirements of PVB12" above the highest sprinkler head

Mostrar más Leer menos
Institución
MBA 706
Grado
MBA 706

Vista previa del contenido

TCEQ IRRIGATION LICENSE STUDY
GUIDE questions and answers
Assembly (RPPA) (RPZ) is required when fertilizer injection are being used.

Causes backsiphonage?✔✔Caused by a negative or Sub-atmospheric pressure.
Example-City departments are using fire hydrant or there's a city main line break, or
someone sucking liquid from a glass using a straw.

Causes of leaking check valve✔✔Debris-can enter the valve. (Can use Y strainer to
provide a solution.)

Definition of high-hazard system?✔✔Non-potable water, chemicals, fertilizers

Definition of cross-connection?✔✔Any actual or potential connection between a
potable water supply and any source of contamination or pollution.
BPA requirements for fertilizer injection system✔✔Reduced Pressure Principle
Degree of hazard✔✔A measure of the degree of risk or harm to the public's health.

General installation requirements of BPA✔✔Device must check/pass Back-
siphonage, Back-pressure, constant pressure, non-health hazard, health hazard.

Installation requirements of AVB✔✔-Installed 6" above the highest head or outlet in
the system.
-No Valves
-Downstream.
-Installed vertically.

Installation and inspection requirements for public water system to BPA✔✔

installation requirements of PVB✔✔12" above the highest sprinkler head
Vertically installed

Installation requirments of RPZ✔✔12" above ground

Installation requirements of DCV✔✔Horizontal or Vertical above or below ground.

Limits of Double check valve✔✔Is a high hazard/health hazard *

Limits of AVB✔✔Can not handle more than 12 hours of constant pressure, not
approved by the state of Texas, does not protect against back-pressure.

purpose of test cocks on DCV✔✔to test check valves and flush

purpose of shut off-valves on PVB✔✔To test and winterize

Escuela, estudio y materia

Institución
MBA 706
Grado
MBA 706

Información del documento

Subido en
17 de octubre de 2024
Número de páginas
2
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$8.49
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Conoce al vendedor
Seller avatar
ExamZen

Conoce al vendedor

Seller avatar
ExamZen Liberty University
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
16
Miembro desde
1 año
Número de seguidores
3
Documentos
539
Última venta
1 mes hace

0.0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes