fdny z51 rmo NEWEST 2024 WITH COMPLETE QUESTIONS AND CORRECT VERIFIED ANSWERS (DETAILED ANSWERS) ALREADY GRADED A+ 100% GUARANTEED TO PASS CONCEPTS!!! A technician has been asked to estimate the cost of operating a 5 horsepower motor because the plant is

Document preview thumbnail
Vista previa 2 fuera de 9 páginas

fdny z51 rmo NEWEST 2024 WITH COMPLETE QUESTIONS AND CORRECT VERIFIED ANSWERS (DETAILED ANSWERS) ALREADY GRADED A+ 100% GUARANTEED TO PASS CONCEPTS!!! A technician has been asked to estimate the cost of operating a 5 horsepower motor because the plant is billed by energy consumed as kilowatt hours the technician will calculate the conversion the equivalent in energy of a 5 horse power motor operating for 9 hours and kilowatt hours is closest to - ANSW..33.6 (one horsepower equals. 746

Vista previa del contenido

fdny z51 rmo NEWEST 2024 WITH COMPLETE QUESTIONS AND CORRECT
VERIFIED ANSWERS (DETAILED ANSWERS) ALREADY GRADED A+ 100%
GUARANTEED TO PASS CONCEPTS!!!




A technician has been asked to estimate the cost of operating a 5 horsepower motor
because the plant is billed by energy consumed as kilowatt hours the technician will
calculate the conversion the equivalent in energy of a 5 horse power motor operating for
9 hours and kilowatt hours is closest to - ✔✔ANSW✔✔..33.6 (one horsepower equals.
746)

The only refrigerant/temperature chart available to refrigerate engineer list the
temperature in ゚C if the chart indicates a Celsius temperature of 5゚ the equivalent In
Fahrenheit is - ✔✔ANSW✔✔..41゚ (1.8 × 5)+ 32 equals)

How do you start a centrifugal chiller - ✔✔ANSW✔✔..Start the chilled water pump then
start the condenser water pump check oil start cooling tower start compressor

A circuit breaker has a similar function as what - ✔✔ANSW✔✔..A fuse

A standpipe system will be out of service for 2 days how long should there be fire watch
- ✔✔ANSW✔✔..The entire time the standpipe is out of service

In a building with a multi zone How does each zone get supplied with water -
✔✔ANSW✔✔..Each zone will have its own automatic water supply

Which service valve should be Install to isolate dual pressure relief valve while keeping
the system in service - ✔✔ANSW✔✔..3 way valve

How many BTU's are removed in a 30 ton system - ✔✔ANSW✔✔..360000 BTU's per
hour

An automatic expansion valve maintains a constant - ✔✔ANSW✔✔..Evaporator
pressure

If the air lovers below the fans in an induced draft cooling tower become clogged the
result would be - ✔✔ANSW✔✔..Higher return water temperature

, You have a cold front and there is a sudden drop in temperature the thermostat will
cause the solenoid valve - ✔✔ANSW✔✔..Close and pump the compress it down and
shut down on low pressure

What happens when a steam turbine reaches critical speed - ✔✔ANSW✔✔..Turbine will
vibrate violently

What Device automatically controls the speed of a steam turbine -
✔✔ANSW✔✔..Governor valve

Under what circumstances is it OK to chain and exit - ✔✔ANSW✔✔..It is never OK

The heat remove from the refrigerator in the condenser is - ✔✔ANSW✔✔..Sensible and
latent heat



the efficiency of the refrigerant cycle is affected by the operation of the condenser. Of
the following, a more efficient centrifugal compressor operation results from -
✔✔ANSW✔✔..lowering the condenser pressure

In most semi hermetic compressors, the suction vapor is used for - ✔✔ANSW✔✔..cools
the motor

The amount of refrigerant that flows through the orifices of an economizer is determined
by the - ✔✔ANSW✔✔..difference between the high side and the low side pressure

the instalation of an inline refrigerant cleaning system is advisable - ✔✔ANSW✔✔..to
remove impurities from the system

a refrigerant engineer verifies that a condenser pump is cavitation of the following the
most likely cause for this condition is: - ✔✔ANSW✔✔..a faulty cooling tower water level
controller

when an expansion valve is operating properly, at the end of the evaporator will contain
- ✔✔ANSW✔✔..only superheated vapor

a centrifugal water pump is considered to be fully primed when - ✔✔ANSW✔✔..the
pump is full of liquid

A refrigeration compressor has failed to turn on. the engineer on duty verifies the
electrical circuit to the motor, including all switches and circuit breakers is complete,
according to recomended service practice, the next item to be checked would likely be
the: - ✔✔ANSW✔✔..temperature and pressure controls

Información del documento

Subido en
14 de octubre de 2024
Número de páginas
9
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$18.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
BestwriterGuru
4.8
(725)
Vendido
257
Seguidores
34
Artículos
5538
Última venta
1 día hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes