• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 2 fuera de 6 páginas
Examen

Air Conditioning Certification Practice Test

Document preview thumbnail
Vista previa 2 fuera de 6 páginas

AIR CONDITIONING CERTIFICATION PRACTICE TEST

Vista previa del contenido

AIR CONDITIONING CERTIFICATION PRACTICE TEST
What is the movement of heat through space called? - Answers-Radiation

A refrigerant release heat when - Answers-It condenses

Why is it desirable for refrigerant in the suction line to be slightly superheated? -
Answers-To insure liquid refrigerant does not enter the compressor

A 30 pound cylinder of reclaimed R-22 refrigerant has been stored over night at 70
degrees F. What should be the approximate pressure in the cylinder? - Answers-121
psig

14.7 psia( pouds per square inch absolute) is - Answers-Approximately 0 PSIG

When testing the efficiency of a water cooled condenser, the refrigerant condensing
temperature should be no more _____ higher than the leaving water temperature. -
Answers-10 degrees F

What does a temperature differential across a filter-drier indicate? - Answers-Restricted
filter-drier

Which of the following symptoms would be indicative of an oil logged evaporator? -
Answers-Reduce heat transfer through the walls of the coil

When using an electronic leak detecto, the sensor probe - Answers-should be moved at
approximately 1 inch per second

Before a vapor / compression system is opened for service - Answers-the refrigerant
must be recovered using approved equipment

What is the minimum vertical drop from the outlet of the condensate drain pan to the
inlet of the P trap when the evaporator is ahead of the blower? - Answers-3 inches

The temperature rise method of determining air volume CFM is mostly used with a/an; -
Answers-electric resistive heat air handler

What is the main fuction of an air condition condenser? - Answers-To remove heat from
the refrigerant

Refrigerant R-134a vapor enters the condenser at 124 psig, 100 degrees F. It leaves the
condenser at 80 degreesF. What will be the approximate pressure? - Answers-124 psig
(the pressure should not change entering or leaving the condenser)

Which of the following CANNOT be used as a low ambient temperature control? -
Answers-Crankcase regulating valve

, When testing the efficiency of a (10 seer are lower) air cooled condenser, the refrigerant
condensing temperature should be no more than_______ higher than the entering air
temperature - Answers-Approximately 30 degrees F

What is a sling psychrometer used to measure - Answers-wet and dry bulb temperature

A compressor is operating with a discharge pressure of 235.3 psig and a suction
pressure of 35.3 psig. What is the compression ratio (pumping ratio)? - Answers-5:1
(235.3+14.7=250) and (35.3+14.7=50) so 250/5=5

What method does hot gas bypass refer to? - Answers-Capacity control

IF a TEV sensing bulb has lost of its charge, What effect would this have on the air
conditioning system - Answers-It would cause the low side pressure to decrease

An increase in water flow, when using a water cooled condenser, would - Answers-
decrease the operating discharge pressure

The clearance space in reciprocating compressor - Answers-has an effect on
compressor capacity

What is used to control the flow of water on a water-cooled condenser? - Answers-A
water regulating valve

How should metallic vibration eliminators be installed on a system which uses a
reciprocating compressor? - Answers-parallel to the compressor crankshaft

The total amount of heat contained in one pound of a substance calculated from an
accepted temperature base is called - Answers-enthalpy

If non-condensables are trapped in a condenser, what symptoms will be present? -
Answers-Increased heat build-up, high amperage and high discharge pressure.

Many multi-cylinder reciprocating compressor have a capacity control device called; -
Answers-un-loaders

A pilot-operated pressure regulator uses_________ pressure to operate the valve. -
Answers-suction gas

A low-side float metering device is used________. - Answers-on a flooded evaporator

In a direct expansion (DX) evaporator system, refrigerant leaves the evaporator as
______. - Answers-superheated vapor

Información del documento

Subido en
12 de octubre de 2024
Número de páginas
6
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$11.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
GEEKA
3.8
(379)
Vendido
2236
Seguidores
1451
Artículos
63298
Última venta
3 horas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes