100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

Commercial Refrigeration Exam Questions and Answers (Graded A)

Puntuación
-
Vendido
-
Páginas
7
Grado
A+
Subido en
19-09-2024
Escrito en
2024/2025

Commercial Refrigeration Exam Questions and Answers (Graded A)Commercial Refrigeration Exam Questions and Answers (Graded A)Commercial Refrigeration Exam Questions and Answers (Graded A)Commercial Refrigeration Exam Questions and Answers (Graded A) The defrost cycle is normally terminated - ANSWER - Based on either temperature, pressure, or time Why would a 35 degree meduim temperature case need to defrost? - ANSWER - The coil temperature for a 35 degree box opertes below freezing The lowest evaporator coil temperature that traditional mechanical systems can attain is approximately - ANSWER - -40 degrees

Mostrar más Leer menos
Institución
Commercial Refrigeration
Grado
Commercial Refrigeration









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Commercial Refrigeration
Grado
Commercial Refrigeration

Información del documento

Subido en
19 de septiembre de 2024
Número de páginas
7
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

Commercial Refrigeration Exam
Questions and Answers (Graded
A)
The defrost cycle is normally terminated - ANSWER - Based on either temperature,
pressure, or time


Why would a 35 degree meduim temperature case need to defrost? - ANSWER - The
coil temperature for a 35 degree box opertes below freezing


The lowest evaporator coil temperature that traditional mechanical systems can
attain is approximately - ANSWER - -40 degrees


A system that maintains temperatures of -250 degrees and below is a - ANSWER -
Cryogenic system


Three common methods of controlling evaporator temperature are - ANSWER -
Conventional thermostat, a suction pressure cut out control, or an evaporator
pressure regulator


When a reach in cooler or freezer is not located near a drain evaporator condensate
is - ANSWER - Drained into a heated pan that evaporates the water


Why is a check valve installed in the auction line of the lowest temperature coil in
multiple evaporator system? - ANSWER - To prevent refrigerant migration from the
higher temperature and pressure coil to the lower temperature and pressure coil


What is commonly used to control defrost operations? - ANSWER - Defrost timer


When multiple compressors are installed in parallel on the same refrigeration
system, provisions must be made to ensure that - ANSWER - The oil level is correct
in all compressors

, What are the broad areas that commercial refrigeration equipment is grouped in
based on the evaporator coil temperature? - ANSWER - High, medium, low, and
cryogenic temperatures


What is the purpose of the door switch on a walk in freezer? - ANSWER - To prevent
warm air from entering the case by shutting off the fans when the door is opened


What is the approximate ventilation requirement for low temperatures, air cooled
condensing units located indoors? - ANSWER - 200 cfm per 1000 btu


A refrigerated case that maintains a temperature of 28 degrees would be classified
as - ANSWER - A medium temperature system


Why should the evaporator not be installed above the door in a walk in cooler or
freezer? - ANSWER - It will draw warm humid air and frost more quickly


What is that normal storage temperature for food items like milk, cheese, fresh
fruits and vegetables? - ANSWER - From 32 degrees to 40 degrees


The first step in selecting commercial refrigeration equipment for a new installation
is to - ANSWER - Perform a heat load calculation to determine the required btu
capacity of the system


What refrigeration component makes it possible to use a single compressor to
control multiple cases at different temperatures? - ANSWER - Evaporator pressure
regulator


What is the advantage of using multiple compressors on a supermarket rack
system? - ANSWER - System capacity can match refrigeration loads that vary over a
wide range


What must be considered when performing a heat load calculation for a walk in
cooler or freezer are - ANSWER - Heat transmission, air infiltration, and product load

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
NursingTutor1 West Virginia University
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
1623
Miembro desde
2 año
Número de seguidores
1073
Documentos
18045
Última venta
9 horas hace
Nursing Tutor

Paper Due? Worry not. Hello. Welcome to NursingTutor. Here you\'ll find verified study materials for your assignments, exams and general school work. All papers here are graded A to help you get the best grade. Also, I am a friendly person so, do not hesitate to send a message in case you have a query. I wish you Luck.

3.8

444 reseñas

5
210
4
76
3
88
2
21
1
49

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes