Typical Operating Conditions for
Commercial Refrigeration Review
Questions and Answers
What is the first thing a technician should know before beginning troubleshooting? -
ANSWER - Knowing the correct operating pressures for a typical system. Also
knowing how the equipment is supposed to function, how it sounds, whether it
should be hot or cool, and when a fan should be operating. pg 649
What is the coil-to-air temperature relationship for a refrigeration system designed
for minimum food dehydration? ABCD - ANSWER - D) 8 - 12 F pg 650
When food dehydration is not a factor, the coil-to-air temperature relationship is
_____ to _____ F. - ANSWER - 16 to 22 pg 650
How is minimum food dehydration accomplished? - ANSWER - By keeping the
relative humidity to 90% and the temperature differential of refrigerant to air at 8 -
12 F. pg 650
Why is minimum dehydration not used on every job? - ANSWER - Not all foods need
minimum dehydration. pg 650
What is the coil-to-air temperature relationship for an average coil where
dehydration is not a factor? - ANSWER - 16 - 22 pg 650
A capillary tube system responds to an overcharge of refrigerant by? ABCD -
ANSWER - D) all of the above. It will have high suction pressure, high head pressure,
and possibly a flooded compressor. pg 659 and 660
How does TXV respond to an undercharge? - ANSWER - The system will be starved
and the suction gage and the discharge gage will read low. pg 688