• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 4 fuera de 126 páginas
Examen

Echo Urr Questions And Answer | Latest Update

Document preview thumbnail
Vista previa 4 fuera de 126 páginas

You identify a PFO on an echo and the cardiologist asks you to calculate the LAP. How will you perform this calculation? -:- Measure the peak velocity across the PFO, calculate the peak pressure gradient across the defect and add the RAP. The mitral deceleration time is 300msec. What is the valve area? A) 1.3cm^2 B) 2.8cm^2 C) 2.5cm^2 D) 1.5cm^2 -:- C) 2.5cm^2 MVA = 759 / deceleration time Which of the following is preferred to document motion of the disk in a St. Jude valve? -:- M-mode. M-mode is used to doc the MOTION of ball/disk in a mechanical valve. Doppler is used to assess the FLOW of the valve. A patient presents for an echo to rule out WMA. The TTE 2D exam is suboptimal. What should you do next? A) cancel the order and dismiss the patient B) consult the physician for permission to perform contrast imaging C) cancel the order and schedule the patient for a TEE D) contact the ordering physician to recommend that an MRI exam is ordered instead 2 | P a g e | G r a d e A + | 2 0 2 4 / 2 0 2 5 2 0 2 4 /2025 | © copyright | This work may not be copied for profit gain | Excel! -:- B) consult the physician for permission to perform contrast imaging; Suboptimal imaging of the LV wall motion on a 2D exam is an indication for contrast administration. A physician order for the contrast must be given, prior to performing the contrast exam. Which Doppler measurement of flow through a stenotic AV best correlated w/ the same value obtained during heart catheterization? -:- mean pressure gradient Which of the following cardiac abnormalities requires the use of the continuity equation for proper calculation of AVA? A) decreased LV function B) HOCM C) supravalvular AS D) Transcatheter AVR -:- A) decreased LV function; The continuity equation compensates for the changes in LV function when calculating AVA. CW Doppler is used to assess flow across the AV. Because CW Doppler has no range resolution, it cannot determine the location of the elevated velocity. HOCM and supravalvular stenosis will cause an improper AVA calculation b/c the stenosis is not at the valve. A transcatheter AV replacement relies on the pressure gradients and the velocity ratio to assess stenosis. The peak velocity of PI can be used to assess: 3 | P a g e | G r a d e A + | 2 0 2 4 / 2 0 2 5 2 0 2 4 /2025 | © copyright | This work may not be copied for profit gain | Excel! A) Peak systolic pulmonary artery pressure B) mean pulmonary artery pressure C) pulmonary artery end diastolic pressure D) severity of pulmonary stenosis -:- B) mean pulmonary artery pressure; MPAP =4 x (peak velocity of PI)^2 The peak velocity of PI is peak diastolic velocity so it cannot be used to assess systolic pressure. The end diastolic velocity of PI can be used to assess the end diastolic pressure in the PA. If the LVOT Doppler tracing is obtained from a location that is too far from the AV: A) the SV will be overestimated B) the AVA will be overestimated by the continuity equation C) the LVOT velocity will be overestimated D) the AVA will be underestimated by continuity equation -:- D) the AVA will be underestimated by continuity equation; If the Doppler cursor is placed too far from the AV, the LVOT peak velocity will be reduced from what it would be at the correct location. This will cause the calculation of a smaller or underestimated AVA or overestimated level of stenosis. The peak aortic velocity and pressure gradient will not match the level of stenosis indicated by AVA. 4 | P a g e | G r a d e A + | 2 0 2 4 / 2 0 2 5 2 0 2 4 /2025 | © copyright | This work may not be copied for profit gain | Excel! What Doppler measurement is necessary to calculate the end diastolic pressure in the pulmonary artery? A) peak pressure gradient of PI B) peak pressure of TR C) end diastolic velocity of PI D) peak systolic velocity of PI -:- C) end diastolic velocity of PI

Vista previa del contenido

2024 /2025 | © copyright | This work may not be copied for profit gain | Excel!




ECHO URR QUESTIONS AND ANSWER |
LATEST UPDATE
You identify a PFO on an echo and the cardiologist asks you to calculate the LAP. How will

you perform this calculation?


✓ -:- Measure the peak velocity across the PFO, calculate the peak

pressure gradient across the defect and add the RAP.




The mitral deceleration time is 300msec. What is the valve area? A) 1.3cm^2 B) 2.8cm^2 C)

2.5cm^2 D) 1.5cm^2


✓ -:- C) 2.5cm^2 MVA = 759 / deceleration time




Which of the following is preferred to document motion of the disk in a St. Jude valve?


✓ -:- M-mode. M-mode is used to doc the MOTION of ball/disk in a

mechanical valve. Doppler is used to assess the FLOW of the valve.




A patient presents for an echo to rule out WMA. The TTE 2D exam is suboptimal. What

should you do next? A) cancel the order and dismiss the patient B) consult the physician for

permission to perform contrast imaging C) cancel the order and schedule the patient for a

TEE D) contact the ordering physician to recommend that an MRI exam is ordered instead




1|P a g e | G r a d e A + | 2 0 2 0 2 5

,2024 /2025 | © copyright | This work may not be copied for profit gain | Excel!



✓ -:- B) consult the physician for permission to p erform contrast imaging;

Suboptimal imaging of the LV wall motion on a 2D exam is an indication

for contrast administration. A physician order for the contrast must be

given, prior to performing the contrast exam.




Which Doppler measurement of flow through a stenotic AV best correlated w/ the same

value obtained during heart catheterization?


✓ -:- mean pressure gradient




Which of the following cardiac abnormalities requires the use of the continuity equation for

proper calculation of AVA? A) decreased LV function B) HOCM C) supravalvular AS


D) Transcatheter AVR


✓ -:- A) decreased LV function; The continuity equation compensates for

the changes in LV function when calculating AVA. CW Doppler is used to

assess flow across the AV. Because CW Doppler has no ran ge resolution,

it cannot determine the location of the elevated velocity. HOCM and

supravalvular stenosis will cause an improper AVA calculation b/c the

stenosis is not at the valve. A transcatheter AV replacement relies on the

pressure gradients and the velocity ratio to assess stenosis.




The peak velocity of PI can be used to assess:


2|P a g e | G r a d e A + | 2 0 2 0 2 5

,2024 /2025 | © copyright | This work may not be copied for profit gain | Excel!


A) Peak systolic pulmonary artery pressure


B) mean pulmonary artery pressure


C) pulmonary artery end diastolic pressure


D) severity of pulmonary stenosis


✓ -:- B) mean pulmonary artery pressure; MPAP =4 x (peak velocity of

PI)^2 The peak velocity of PI is peak diastolic velocity so it cannot be

used to assess systolic pressure. The end diastolic velocity of PI can be

used to assess the end diastolic pressure in t he PA.




If the LVOT Doppler tracing is obtained from a location that is too far from the AV:


A) the SV will be overestimated


B) the AVA will be overestimated by the continuity equation


C) the LVOT velocity will be overestimated


D) the AVA will be underestimated by continuity equation


✓ -:- D) the AVA will be underestimated by continuity equation; If the

Doppler cursor is placed too far from the AV, the LVOT peak velocity

will be reduced from what it would be at the correct location. This will

cause the calculation of a smaller or underestimated AVA or

overestimated level of stenosis. The peak aortic velocity and pressure

gradient will not match the level of stenosis indicated by AVA.



3|P a g e | G r a d e A + | 2 0 2 0 2 5

, 2024 /2025 | © copyright | This work may not be copied for profit gain | Excel!




What Doppler measurement is necessary to calculate the end diastolic pressure in the

pulmonary artery?


A) peak pressure gradient of PI


B) peak pressure of TR


C) end diastolic velocity of PI


D) peak systolic velocity of PI


✓ -:- C) end diastolic velocity of PI; PA end diastolic pressure = 4 (end

diastolic pressure velocity of PI)^2 + RA pressure; normal PAEDP + 4 -

12mmhg




If _________________ is present, the RVSP calculation from the TR gradient is inaccurate

as the measurement of the PAP.


A) CHF


B) PI


C) PS


D) PHTN


✓ -:- C) PS; The PA pressure is used to assess the pressure in the lungs. If

the PV is stenotic, the flow velocity and resistance increase the pressures



4|P a g e | G r a d e A + | 2 0 2 0 2 5

Información del documento

Subido en
17 de septiembre de 2024
Número de páginas
126
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$13.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
ScholarsAscend
3.7
(84)
Vendido
531
Seguidores
40
Artículos
30967
Última venta
2 días hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes