100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

Chapter 8 – Radon Practice Questions and Answers | 100% Pass

Puntuación
-
Vendido
-
Páginas
6
Grado
A+
Subido en
16-09-2024
Escrito en
2024/2025

Chapter 8 – Radon Practice Questions and Answers | 100% Pass A client expresses concern because, during a 7-day charcoal canister short-term test, a brief thunderstorm passes over the home. Which of the following would be the MOST APPROPRIATE response to give this client? - Answer️️ -Since the measurement period is 7 days, the test will still be valid. A post-mitigation radon measurement device should be placed: - Answer️️ -in the same location as the pre-mitigation test device. According to EPA Measurement Protocols, a single radon test is acceptable for a real estate transaction under which of the following conditions? - Answer️️ -A 48-hour measurement with an active continuous monitor which can integrate and record a new result hourly or less. According to the simultaneous test option for real estate transactions, when one result is greater than 4 pCi/L and the other result is less than 4 pCi/L, a re-test is recommended if the: - Answer️️ -higher result is greater than twice the lower result. Follow-up measurements should always be taken: - Answer️️ -in the same location as the initial measurement. For passive (no pump) continuous monitors, the first 4 hours of data are discarded to allow: - Answer️️ -the instrument to reach equilibrium. ©SOPHIABENNETT EXAM SOLUTIONS_2024/2025 Tuesday, September 3, 2024 10:30 AM Page | 2 How close to one another must two charcoal detectors be placed if they are to be considered collocated test devices for real estate testing? - Answer️️ -4 inches In a real estate test, two activated charcoal canisters measured 1.5 pCi/L and 5.5 pCi/L after exposure for 48 hours at opposite ends of an occupied basement. The client should be informed that: - Answer️️ -When two collocated passive devices (4 inches apart) are on opposite sides of the 4.0 pCi/L guidance the results should not vary more than 2-fold. In this case one is above 4 and the other is below 4 AND 5.5 is more than two times the lower result of 1.5. Because of this wide variation the results are to be thrown out and the test repeated. The correct answer is: The two results are too far apart and

Mostrar más Leer menos
Institución
Radon
Grado
Radon









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Radon
Grado
Radon

Información del documento

Subido en
16 de septiembre de 2024
Número de páginas
6
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

©SOPHIABENNETT
EXAM_SOLUTIONS GUARANTEED SUCCESS 2024/2025 ACADEMIC YEAR




©SOPHIABENNETT 9/3/24 2024/2025

, ©SOPHIABENNETT EXAM SOLUTIONS_2024/2025 Tuesday, September 3, 2024 10:30 AM



Chapter 8 – Radon Practice Questions
and Answers | 100% Pass


A client expresses concern because, during a 7-day charcoal canister short-term test,

a brief thunderstorm passes over the home. Which of the following would be the MOST

APPROPRIATE response to give this client? - Answer✔️✔️-Since the measurement

period is 7 days, the test will still be valid.


A post-mitigation radon measurement device should be placed: - Answer✔️✔️-in the

same location as the pre-mitigation test device.

According to EPA Measurement Protocols, a single radon test is acceptable for a real

estate transaction under which of the following conditions? - Answer✔️✔️-A 48-hour

measurement with an active continuous monitor which can integrate and record a new

result hourly or less.

According to the simultaneous test option for real estate transactions, when one result is

greater than 4 pCi/L and the other result is less than 4 pCi/L, a re-test is recommended

if the: - Answer✔️✔️-higher result is greater than twice the lower result.

Follow-up measurements should always be taken: - Answer✔️✔️-in the same location as

the initial measurement.

For passive (no pump) continuous monitors, the first 4 hours of data are discarded to

allow: - Answer✔️✔️-the instrument to reach equilibrium.




Page | 1

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
SophiaBennett Howard Community College
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
131
Miembro desde
1 año
Número de seguidores
5
Documentos
9104
Última venta
1 semana hace
EXAM GAME-CHANGER

Exam Questions and Answers Section : Study Like a Pro, Study Smart, Study with Sophia.

3.7

26 reseñas

5
10
4
5
3
7
2
1
1
3

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes