Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 3 fuera de 23 páginas
Examen

RAD TCDHA FINAL EXAM NEWEST 2024 WITH UPDATED QUESTIONS AND DETAILED CORRECT ANSWERS WITH RATIONALES (ALREADY GRADED A+)

Document preview thumbnail
Vista previa 3 fuera de 23 páginas

RAD TCDHA FINAL EXAM NEWEST 2024 WITH UPDATED QUESTIONS AND DETAILED CORRECT ANSWERS WITH RATIONALES (ALREADY GRADED A+) what technique examines the crowns of both maxillary and mandibular teeth on a single image - ANSWER-interproximal examination you have been asked to take a dental image of your patients mandible. what image would you take - ANSWER-occlusal parallel is defined as - ANSWER-Moving or lying in the same plane, always separated by the same distance and not intersecting image magnification occurs when the ...... distance is increased - ANSWER-object-receptor what receptor holder includes aiming rings that aid in the alignment 2 | P a g e of the PID with the receptor - ANSWER-Rinn XCP instruments when using film, the dot should always be placed in relation to the bite block - ANSWER-in the slot 3 | P a g e elongated images refer to images of the teeth that appear ........... elongation of images results from ........ vertical angulation - ANSWER-too long; insufficient receptor should be replaced approximately ....... inch beyond the incisal or occlusal surfaces when using the bisecting technique - ANSWER-1/8 according to the text, when exposing the anterior teeth using the bisecting technique, there are ........... recommended size 2 periodical receptor placements - ANSWER-6 (1) according to the text, the advantages of the bisecting technique are greater than the disadvantages (2) therefore, the bisecting technique should be used instead of the paralleling technique when taking periodical images - ANSWER-both statements are false for the mandibular molar exposure, the medial edge of the receptor should be aligned with the midline of the - ANSWER- second 4 | P a g e premolar what vertical angulation should you use when adjusting the PID to take bite-wing images with bite-tabs? - ANSWER-+10 degrees ionization - ANSWER-an atom that gains an electron has a negative charge, and an atom that loses an electron has a positive charge ionizing radiation - ANSWER-radiation that is capable of producing ions by removing or adding an electron to an atom Heat is a byproduct of x-ray production. Which component of the x ray tubehead dissipates the heat created by the production of x- rays? - ANSWER-insulation oil the head collimator - ANSWER-restricts the size of the x-ray beam which would you adjust if you wanted to create a larger electron

Vista previa del contenido

1|Page


RAD TCDHA FINAL EXAM NEWEST 2024 WITH

UPDATED QUESTIONS AND DETAILED

CORRECT ANSWERS WITH RATIONALES

(ALREADY GRADED A+)



what technique examines the crowns of both maxillary and

mandibular teeth on a single image - ANSWER-interproximal

examination

you have been asked to take a dental image of your patients

mandible. what image would you take - ANSWER-occlusal



parallel is defined as - ANSWER-Moving or lying in the same

plane, always separated by the same distance and not intersecting



image magnification occurs when the ...... distance is increased -

ANSWER-object-receptor



what receptor holder includes aiming rings that aid in the alignment

,2|Page


of the PID with the receptor - ANSWER-Rinn XCP instruments



when using film, the dot should always be placed in

relation to the bite block - ANSWER-in the slot

, 3|Page




elongated images refer to images of the teeth that appear ...........

elongation of images results from ........ vertical angulation -

ANSWER-too long; insufficient



receptor should be replaced approximately ....... inch beyond the

incisal or occlusal surfaces when using the bisecting technique -

ANSWER-1/8



according to the text, when exposing the anterior teeth using the

bisecting technique, there are ........... recommended size 2

periodical receptor placements - ANSWER-6



(1) according to the text, the advantages of the bisecting technique

are greater than the disadvantages (2) therefore, the bisecting

technique should be used instead of the paralleling technique when

taking periodical images - ANSWER-both statements are false

for the mandibular molar exposure, the medial edge of the receptor

should be aligned with the midline of the - ANSWER- second

Información del documento

Subido en
10 de septiembre de 2024
Número de páginas
23
Escrito en
2024/2025
Tipo
Examen
Contiene
Desconocido
$20.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
TopGradeExams
4.1
(21)
Vendido
142
Seguidores
4
Artículos
4518
Última venta
3 días hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes