URR mock Test 1 Questions With Correct Answers. Which of the following transducers will produce the highest frequency sound waves? A. 6mm element thickness, 2mm/μs propagation speed of the element B. 2mm element thickness, 6mm/μs propagation speed of the element C. 6mm element thickness, 6mm/μs propagation speed of the element D. 2mm element thickness, 2mm/μs propagation speed of the element - answer2mm element thickness, 6mm/μs propagation speed of the element The narrowest portion of a beam produced by a focused ultrasound transducer is: A. the focal point B. the Fresnel zone C. the Fraunhofer zone D. the first centimeter of the beam that leaves the transducer - answerthe focal point If a Doppler system is operating at a PRF of 5000/s what is the maximum Doppler frequency that can be detected? A. 2500kHz B. 500kHz C. 2.5kHz D. 5kHz - answer2.5kHz Why does Doppler tracing not touch the baseline on either side? A. high filter settings B. decreased Doppler gain settings C. spectral broadening ©THEBRIGHT EXAM STUDY SOLUTIONS 8/27/2024 12:01 PM D. decreased rejection settings - answerhigh filter settings Which of the following statements correctly describes annular arrays? A. an annular array can electronically focus the beam B. an annular array can use phasing to electronically steer the beam C. annular arrays provide the lowest slice thickness resolution D. annular arrays usually contain 30 or more circular elements - answeran annular array can electronically focus the beam Which of the following describes the primary advantage of a 1.5D array over a 1D array? A. the 1.5D array eliminates the need for a stand-off pad for superficial imaging B. the 1.5D array can produce a trapezoid field of view while the 1D array can only produce a rectangular field of view C. the 1.5D array allows for 3D imaging while the 1D array does not D. the 1.5D array allows for variable elevation focus while the 1D array has a fixed elevation focus - answerthe 1.5D array allows for variable elevation focus while the 1D array has a fixed elevation focus What wave parameter is defined as the wavelength times the number of cycles in the pulse? A. period B. spatial pulse length C. pulse repetition frequency D. pulse duration - answerspatial pulse length You are scanning a thyroid gland with a 5cm wide linear array transducer. You are unable to document the upper and lower poles in the same image to obtain a length measurement of the gland. Which of the following techniques would assist in documenting the entire thyroid gland on a single image? A. spatial compounding B. electronic focusing C. 3D volume rendering D. panoramic imaging - answerpanoramic imaging The average speed of sound in soft tissue is: ©THEBRIGHT EXAM STUDY SOLUTIONS 8/27/2024 12:01 PM A. 1580m/s B. 3300m/s C. 1540m/s D. 1540cm/s - answer1540m/s Which of the following is NOT the proper procedure for disinfection of instruments between patients? A. saniwipes or Cidex can be used to disinfect the transducer after each ultrasound exam B. sonographers should wash their hands after each exam, even if gloves were used C. all biopsy needles should be sent out for sterilization after each use D. gel bottles should be sanitized daily using disinfectant cleanser - answerall biopsy needles should be sent out for sterilization after each use Which of the following correctly describes the color displayed on the image? A. the color scale should be reduced so that the entire vessel is filled with blue color B. the color scale should be reduced so that the entire vessel is filled with red color C. the red and blue colors indicate that flow is moving in two different directions simultaneously in the vessel D. the heel-to-toe method can be used to change the course of the vessel across the image and this will allow the vessel to accurately display a single color - answerthe heel-to-toe method can be used to change the course of the vessel across the image and this will allow the vessel to accurately display a single color What effect will increased hematocrit levels have on an arterial duplex exam? A. hematocrit levels do not affect a Doppler evaluation B. decreased blood viscosity C. increased color flow display D. decreased blood flow velocities - answerdecreased blood flow velocities When using a tissue ph

Mostrar más Leer menos
Institución
URR
Grado
URR










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
URR
Grado
URR

Información del documento

Subido en
29 de agosto de 2024
Número de páginas
25
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

©THEBRIGHT EXAM STUDY SOLUTIONS 8/27/2024 12:01 PM



URR mock Test 1 Questions With Correct
Answers.


Which of the following transducers will produce the highest frequency sound waves?
A. 6mm element thickness, 2mm/μs propagation speed of the element
B. 2mm element thickness, 6mm/μs propagation speed of the element
C. 6mm element thickness, 6mm/μs propagation speed of the element

D. 2mm element thickness, 2mm/μs propagation speed of the element - answer✔✔2mm element
thickness, 6mm/μs propagation speed of the element
The narrowest portion of a beam produced by a focused ultrasound transducer is:
A. the focal point
B. the Fresnel zone
C. the Fraunhofer zone

D. the first centimeter of the beam that leaves the transducer - answer✔✔the focal point
If a Doppler system is operating at a PRF of 5000/s what is the maximum Doppler frequency that
can be detected?
A. 2500kHz
B. 500kHz
C. 2.5kHz

D. 5kHz - answer✔✔2.5kHz
Why does Doppler tracing not touch the baseline on either side?
A. high filter settings
B. decreased Doppler gain settings
C. spectral broadening

, ©THEBRIGHT EXAM STUDY SOLUTIONS 8/27/2024 12:01 PM


D. decreased rejection settings - answer✔✔high filter settings
Which of the following statements correctly describes annular arrays?
A. an annular array can electronically focus the beam
B. an annular array can use phasing to electronically steer the beam
C. annular arrays provide the lowest slice thickness resolution

D. annular arrays usually contain 30 or more circular elements - answer✔✔an annular array can
electronically focus the beam
Which of the following describes the primary advantage of a 1.5D array over a 1D array?
A. the 1.5D array eliminates the need for a stand-off pad for superficial imaging
B. the 1.5D array can produce a trapezoid field of view while the 1D array can only produce a
rectangular field of view
C. the 1.5D array allows for 3D imaging while the 1D array does not
D. the 1.5D array allows for variable elevation focus while the 1D array has a fixed elevation
focus - answer✔✔the 1.5D array allows for variable elevation focus while the 1D array has a
fixed elevation focus
What wave parameter is defined as the wavelength times the number of cycles in the pulse?
A. period
B. spatial pulse length
C. pulse repetition frequency

D. pulse duration - answer✔✔spatial pulse length
You are scanning a thyroid gland with a 5cm wide linear array transducer. You are unable to
document the upper and lower poles in the same image to obtain a length measurement of the
gland. Which of the following techniques would assist in documenting the entire thyroid gland
on a single image?
A. spatial compounding
B. electronic focusing
C. 3D volume rendering

D. panoramic imaging - answer✔✔panoramic imaging
The average speed of sound in soft tissue is:

, ©THEBRIGHT EXAM STUDY SOLUTIONS 8/27/2024 12:01 PM


A. 1580m/s
B. 3300m/s
C. 1540m/s

D. 1540cm/s - answer✔✔1540m/s
Which of the following is NOT the proper procedure for disinfection of instruments between
patients?
A. saniwipes or Cidex can be used to disinfect the transducer after each ultrasound exam
B. sonographers should wash their hands after each exam, even if gloves were used
C. all biopsy needles should be sent out for sterilization after each use

D. gel bottles should be sanitized daily using disinfectant cleanser - answer✔✔all biopsy needles
should be sent out for sterilization after each use
Which of the following correctly describes the color displayed on the image?
A. the color scale should be reduced so that the entire vessel is filled with blue color
B. the color scale should be reduced so that the entire vessel is filled with red color
C. the red and blue colors indicate that flow is moving in two different directions simultaneously
in the vessel
D. the heel-to-toe method can be used to change the course of the vessel across the image and
this will allow the vessel to accurately display a single color - answer✔✔the heel-to-toe method
can be used to change the course of the vessel across the image and this will allow the vessel to
accurately display a single color
What effect will increased hematocrit levels have on an arterial duplex exam?
A. hematocrit levels do not affect a Doppler evaluation
B. decreased blood viscosity
C. increased color flow display

D. decreased blood flow velocities - answer✔✔decreased blood flow velocities
When using a tissue phantom to evaluate range accuracy, what unit will be used to report the
measurement?
A. centimeter
B. micrometer
$10.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Thumbnail
Package deal
URR Exam Package Deal.
-
20 2024
$ 236.80 Más información

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Thebright Florida State University
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
173
Miembro desde
1 año
Número de seguidores
6
Documentos
12345
Última venta
4 horas hace
Topscore Emporium.

On this page, you find verified, updated and accurate documents and package deals.

3.8

35 reseñas

5
13
4
10
3
7
2
1
1
4

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes