URR mock exam 1 SPI Exam Questions With Correct Answers. ____ is defined as specific area or location where Doppler shift info is being obtained. A. spectral broadening B. nyquist limit C. sample volume D. spectral window - answerC. sample volume Spatial resolution is: A. the minimum reflector separation required to produce separate echos. B. highest with linear phased arrays. C. the weakest reflected signal the transducer can receive D. another term for slice thickness resolution - answerA. the minumum reflector separation required to produce echos Which of the following Doppler angles would lead to the most significant error in estimation of the flow velocity? A. 25 B. 45 C. 65 D. 80 - answerD. 80 which of the following necessary machine setting with performing a contrast evolution of the heart? A. harmonic imaging off B. mechincal index set to 0.3 or lower C. mechanical index set to 1.0 or greater ©THEBRIGHT EXAM STUDY SOLUTIONS 8/27/2024 12:01 PM D. Low PRF color Doppler setting - answerB. mechanical index set to 0.3 or lower How many pulses are needed per scan line in order to generate a single frame of color Doppler? A. 6 B. 1 C. 16 D. 3 - answerD. 3 The rectus abdominis muscles are associated with ____, while the diaphragm is associated with ______. A. shadowing, enhancement B. comet tail, ring down C. refractive shadowing, lobe artifact D. refraction artifact, mirror image artifact - answerD. refraction artifact, mirror image artifact When evaluating a suspected arterial stenosis, a doppler angel of ____ degrees will produce the most accurate flow velocity. A. 0 B. 30 C. 60 D. 90 - answerA. 0 Increasing the angle of electronic steering causes _____ production of lobe artifact. A. increased B. decreased C. no change D. limited - answerA. increased Put the following media in order from lowest to highest according to their acoustic impedance: Bone Air Liver ©THEBRIGHT EXAM STUDY SOLUTIONS 8/27/2024 12:01 PM Blood - answerAir, blood, liver, bone Even and odd harmonic frequencies are created by: A. alternating current to different piezoelectric elements in the transducer array B. non-linear sound wave propagation C. variable timing of the firing of the piezoelectric elements D. turbulent flow in the blood vessel - answerB. non-linear sound wave propagation what type of transducer array has the fewest numbers of elements? A. linear phased array B. annular array C. curvilinear sequential array D. mechanical transducer - answerB. annular array ______ artifact is caused by refraction and results in subtle image degradation. A. comet tail B. scatter C. misregistration D. multipath - answerD. multipath Which of the following will improve lateral resolution at all depths on the image? A. dynamic transmit focusing B. dynamic receive focusing C. decrease probe frequency D. use >3 focal zones - answerB. dynamic receive focusing which of the following units is used to describe beam intensity? A. dB/cm/MHz B. dB C. mW/cm 2 D. mW - answerC. mW/cm

Mostrar más Leer menos
Institución
URR
Grado
URR











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
URR
Grado
URR

Información del documento

Subido en
29 de agosto de 2024
Número de páginas
35
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

©THEBRIGHT EXAM STUDY SOLUTIONS 8/27/2024 12:01 PM



URR mock exam 1 SPI Exam Questions With
Correct Answers.


____ is defined as specific area or location where Doppler shift info is being obtained.
A. spectral broadening
B. nyquist limit
C. sample volume

D. spectral window - answer✔✔C. sample volume
Spatial resolution is:
A. the minimum reflector separation required to produce separate echos.
B. highest with linear phased arrays.
C. the weakest reflected signal the transducer can receive

D. another term for slice thickness resolution - answer✔✔A. the minumum reflector separation
required to produce echos
Which of the following Doppler angles would lead to the most significant error in estimation of
the flow velocity?
A. 25
B. 45
C. 65

D. 80 - answer✔✔D. 80
which of the following necessary machine setting with performing a contrast evolution of the
heart?
A. harmonic imaging off
B. mechincal index set to 0.3 or lower
C. mechanical index set to 1.0 or greater

, ©THEBRIGHT EXAM STUDY SOLUTIONS 8/27/2024 12:01 PM


D. Low PRF color Doppler setting - answer✔✔B. mechanical index set to 0.3 or lower
How many pulses are needed per scan line in order to generate a single frame of color Doppler?
A. 6
B. 1
C. 16

D. 3 - answer✔✔D. 3
The rectus abdominis muscles are associated with ____, while the diaphragm is associated with
______.
A. shadowing, enhancement
B. comet tail, ring down
C. refractive shadowing, lobe artifact

D. refraction artifact, mirror image artifact - answer✔✔D. refraction artifact, mirror image
artifact
When evaluating a suspected arterial stenosis, a doppler angel of ____ degrees will produce the
most accurate flow velocity.
A. 0
B. 30
C. 60

D. 90 - answer✔✔A. 0
Increasing the angle of electronic steering causes _____ production of lobe artifact.
A. increased
B. decreased
C. no change

D. limited - answer✔✔A. increased
Put the following media in order from lowest to highest according to their acoustic impedance:
Bone
Air
Liver

, ©THEBRIGHT EXAM STUDY SOLUTIONS 8/27/2024 12:01 PM


Blood - answer✔✔Air, blood, liver, bone
Even and odd harmonic frequencies are created by:
A. alternating current to different piezoelectric elements in the transducer array
B. non-linear sound wave propagation
C. variable timing of the firing of the piezoelectric elements

D. turbulent flow in the blood vessel - answer✔✔B. non-linear sound wave propagation
what type of transducer array has the fewest numbers of elements?
A. linear phased array
B. annular array
C. curvilinear sequential array

D. mechanical transducer - answer✔✔B. annular array
______ artifact is caused by refraction and results in subtle image degradation.
A. comet tail
B. scatter
C. misregistration

D. multipath - answer✔✔D. multipath
Which of the following will improve lateral resolution at all depths on the image?
A. dynamic transmit focusing
B. dynamic receive focusing
C. decrease probe frequency

D. use >3 focal zones - answer✔✔B. dynamic receive focusing
which of the following units is used to describe beam intensity?
A. dB/cm/MHz
B. dB
C. mW/cm 2

D. mW - answer✔✔C. mW/cm 2

, ©THEBRIGHT EXAM STUDY SOLUTIONS 8/27/2024 12:01 PM


which of the following parameters cannot be evaluated by the AIUM test object?
A. depth calibration
B. distance calibration
C. gray scale

D. azimuthal resolution - answer✔✔C. gray scale
ultrasound hybrid imaging refers to :
A. using 2D ultrasound imaging with microbubble contrast
B. automated ultrasound imaging
C. fusion of real time ultrasound imaging with another modality to form a new evaluation
technique

D. comparing ultrasound images to a CT exam on a PACS system - answer✔✔C. fusion of real
time ultrasound imaging with another modality to form a new evaluation technique
which of the following system adjustments would increase the size of the spectral window?
A. decreasing rejection
B. changing from a 2mm to 4mm sample size
C. changing from a 4mm to 2mm sample size

D. tortuous vessel - answer✔✔C. changing from a 4mm to 2mm sample size
In read magnification, image size and _____ increases. In write magnification, image size and
____ increases.
A. pixel size, number of pixels
B. number of pixels, pixel size
C. reflection amplitude, transmitted amplitude

D. frame rate, time of frame production - answer✔✔A. pixel size, number of pixels
If the lines per frame increases and the depth remains the same, what other system parameter
must change for sound wave production?
A. propagation speed of the sound produced
B. signal to noise ratio
C. frequency
$12.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Thumbnail
Package deal
URR Exam Package Deal.
-
20 2024
$ 236.80 Más información

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Thebright Florida State University
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
173
Miembro desde
1 año
Número de seguidores
6
Documentos
12345
Última venta
4 horas hace
Topscore Emporium.

On this page, you find verified, updated and accurate documents and package deals.

3.8

35 reseñas

5
13
4
10
3
7
2
1
1
4

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes