100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

2024 OSP-001 PRACTISE TEST EXAM WITH CORRECT ANSWERS

Puntuación
-
Vendido
-
Páginas
48
Grado
A+
Subido en
22-08-2024
Escrito en
2024/2025

2024 OSP-001 PRACTISE TEST EXAM WITH CORRECT ANSWERS

Institución
OSP-001
Grado
OSP-001











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
OSP-001
Grado
OSP-001

Información del documento

Subido en
22 de agosto de 2024
Número de páginas
48
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

2024 OSP-001 PRACTISE TEST
EXAM WITH CORRECT ANSWERS

in areas where future excavation is anticipated, it may be advisable to place
the cable at a greater depth. For example, if road grading that will remove
610 mm (24 in) of dirt is planned in a particular area, it would be wiser to
initially place the cable at 1.2 m (4 ft) versus the standard
610 mm (24 in). - CORRECT-ANSWERSTrue

OSP designers need to give special consideration to telecommunications
services at ______ - CORRECT-ANSWERSmarinas

OSP designers need to give special consideration to telecommunications
services at marinas because of the following unique conditions: - CORRECT-
ANSWERS• Changing water levels
• High moisture and humidity
• Severe weather (e.g., winds, waves, sun)
• Potential for deterioration of the distribution cable ( cable damage )
• Salt (corrosive environment)
• Transience of boat owners ( temporary )
• Difficulty in establishing a dependable and approved electrical grounding
point

The space reserved for a boat adjacent to a dock is _______ - CORRECT-
ANSWERSBoat slip

A portion of a dock that is publicly accessible to all marina users is call
________ - CORRECT-ANSWERSCommon element

placing all of the conduits during the initial conduit system installation is
desirable,
if not mandatory.
*True
*False - CORRECT-ANSWERSTrue


A portion of a dock that is accessible only to those boat
slips that it serves on either side is call ________ - CORRECT-ANSWERSLimited
common element (LCE)

A boat slip that is owned or subleased is ________ - CORRECT-
ANSWERSCondominium slip

,To accommodate the movement of a floating dock to and from a shoreline,
the following arrangements should be used: - CORRECT-ANSWERS• Hose-
reeling cable on a floating section
• A point of connection at both ends of a dock section to ease adding or
removing sections
of cable
• Jack and plug arrangements for smaller installations that need only a few
service cables
• Cables placed in a festoon arrangement, similar to the festooned cables
placed on
bleachers that are retracted and expanded

It is known in advance that all or most of the boat slips require
telecommunications services - CORRECT-ANSWERSPrecable each boat slip
during construction of the dock. For security, each run should be terminated
in the patch panel cross-connect at the dock master or marina office.

Fewer than 10 boat slips are cabled - CORRECT-ANSWERSRun one- or two-
pair cables from the boat slips to a distribution terminal on the closest point
of land.

If 10 or more boat slips are cabled - CORRECT-ANSWERSPlace distribution
cable onto the dock and terminate in a suitable cabinet or enclosure. Run
service drop to each boat slip.

All cable splices should be mechanically protected from the harsh
environment using: - CORRECT-ANSWERS• Conduit.
• Cable trays.
• Weatherproof enclosures.
• Other structures suited for harsh, outdoor conditions.

______ cable on docks should be used. - CORRECT-ANSWERSWater-blocked

in marinas the type and size of conduit can be selected following these
guidelines: - CORRECT-ANSWERS• Use rigid nonmetallic conduit wherever
possible.
• Join the sections of rigid conduit with flexible duct where movement of a
dock is probable.
• Use minimum 21 mm (3/4 trade size) conduits for service cables to each
slip.

a common telecommunications conduit within a prefabricated dock section
might be the only available cabling medium: - CORRECT-ANSWERS• In areas
where direct local exchange service and public telephone service are
provided by

,different companies.
• Where CATV is requested.

When an individual boat slip is owned and subleased as a regular
condominium, only the two bordering boat slip owners can legally use a
finger slip, a limited common element.

True
False - CORRECT-ANSWERSTrue


It is not always necessary to build new pathways for cable placement
*True
*False - CORRECT-ANSWERSTrue

The length of a cable loop from the switch to a customer depends on three
factors - CORRECT-ANSWERS• Resistance of the cable in ohms
• Signaling limits of the telephone and the terminating device switch in ohms
• Pair loading

Outside Plant (OSP) - CORRECT-ANSWERSTelecommunications OSP cabling
began with the placement of the first telegraph system,

Cable Types - CORRECT-ANSWERS• Optical fiber:
- 62.5/125 micrometer (μm) multimode optical fiber (OM1).
- 50/125 μm multimode optical fiber (OM2, OM3, and OM4).
- Singlemode optical fiber (OS1 and OS2).
• 100-ohm balanced twisted-pair.
• 75-ohm coaxial.

Codes - CORRECT-ANSWERSrules specified by governmental entities

Installation manuals are examples of - CORRECT-ANSWERSMethodology

Support structures: - CORRECT-ANSWERS- MHs).
- (HHs).
- Poles, support strands, and guying information.

The basic types of OSP pathways and spaces are: - CORRECT-ANSWERS•
Underground.
• Direct-buried.
• Aerial.

advantage to use optical fiber in backbones campus applications: -
CORRECT-ANSWERS• Increased distance.
• Higher bandwidth applications.

, • All-dielectric cable.
• Less susceptibility to EMI and lightning.
• No crosstalk.
• No grounding (earthing) requirement for all-dielectric cable.

Optical Fiber Connectors: - CORRECT-ANSWERS• LC
• SC
• ST

How to calculate passive cable system attenuation - CORRECT-
ANSWERSTotal optical fiber loss
+ Total connector loss
+ Total splice loss

Calculate link loss budget - CORRECT-ANSWERSSystem gain - Power
penalties

Splice loss values - CORRECT-ANSWERSMM SM
SP type Avr. max. Avr. max.

Fusion 0.05 0.3 0.05 0.3
Mecha 0.10 0.3 0.10 0.3

Ribbon fiber - CORRECT-ANSWERSdesigns can be single tube or
multitube ,the fiber is bound in a flat array

Tight-buffered fibers - CORRECT-ANSWERShave a 900 μm coating applied
directly to the optical fiber.

A transition point shall be required for unlisted OSP cable when the
termination
point is greater than _________ from the point of entrance and the cable
cannot
be installed in a properly rated conduit. - CORRECT-ANSWERS15 m (50 ft)

NEMA - CORRECT-ANSWERSNational Electrical Manufacturers Association

Most blown fiber systems publish maximum blowing distances of ____________
without
employing advanced blowing techniques. - CORRECT-ANSWERS1 km (3281
ft)

ITU G.652D - CORRECT-ANSWERSSinglemode, low water, nondispersion-
shifted fiber [NDSF]
$20.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Elitaa Chamberlain university
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
172
Miembro desde
1 año
Número de seguidores
25
Documentos
7141
Última venta
19 horas hace
A+ Academic Resources provides high-quality exam materials, assignments, past papers, and verified study documents to help students achieve top grades with confidence. Our resources are carefully organized to support effective learning.

We have just re-established our shop, my aim is to elevate and guide students academically with actual guides and exams 100% verified.Incase you dont find the exam that you are looking for,feel free to inbox me and request any exam.My prices are never fixed,always negotiable , WELCOME ,LETS BEGIN.

3.6

25 reseñas

5
10
4
5
3
5
2
1
1
4

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes