CT REGISTRY STUDY GUIDE QUESTIONS WITH CORRECT ANSWERS FOR GARANTEED PASS What determines how much and what section of the collected raw data is used to create an image - Correct Answer Display field of view The "string of beads" artifact is most closely associated with which of the following? - Correct Answer Maximum intensity projection images A patient has a severe vagal reaction to iodinated contrast material that includes bradycardia should be given a treatment of - Correct Answer *treatment includes increasing blood pressure with IV fluids *intravenous administration of atropine to block vagal stimulation of the heart An MDCT image is reconstructed using a 512x512 matrix and a display field of view of 44 cm. If the detector collimation is set to a section width of 2.5 mm what is the volume of each voxel - Correct Answer How to solve: The linear dimension of the pixel must first be calculated by dividing the DFOV, in mm, by the matrix. This linear pixel dimension is squared to yield the pixel area in mm^2. The volume of the voxel may be calculated by multiplying the pixel area by the section width step 1. 44 cm/ 512 =0.0859 step 2. 0.0859*2.5 mm = 0.2148 step 3. move the decimal point =2.15 mm^3 For a particular CT scanner's beam quality, the linear attenuation coefficient for water is 0.20 cm-1 and for a certain tumor is 0.21 cm-1. What is the CT number of the tumor? - Correct Answer Equation (.21-.20/.21) × 1000= 50 A CT system measures the average linear attenuation coefficient of a voxel of tissue to be 0.189. The linear coefficient of water for this scanner is 0.181. The CT number assigned to the pixel representing this tissue is - Correct Answer 44 HU use equation above A CT scanner capable of producing an image that is a perfect reproduction of the actual anatomic section is said to have an MTF modulator transfer function of - Correct Answer 1

Mostrar más Leer menos
Institución
CT REGISTRY
Grado
CT REGISTRY









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
CT REGISTRY
Grado
CT REGISTRY

Información del documento

Subido en
18 de agosto de 2024
Número de páginas
11
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

CT REGISTRY STUDY GUIDE QUESTIONS
WITH CORRECT ANSWERS FOR GARANTEED
PASS
What determines how much and what section of the collected raw data is used to create an image -
Correct Answer Display field of view



The "string of beads" artifact is most closely associated with which of the following? - Correct Answer
Maximum intensity projection images



A patient has a severe vagal reaction to iodinated contrast material that includes bradycardia should
be given a treatment of - Correct Answer *treatment includes increasing blood pressure with IV
fluids

*intravenous administration of atropine to block vagal stimulation of the heart



An MDCT image is reconstructed using a 512x512 matrix and a display field of view of 44 cm. If the
detector collimation is set to a section width of 2.5 mm what is the volume of each voxel - Correct
Answer How to solve: The linear dimension of the pixel must first be calculated by dividing the DFOV,
in mm, by the matrix. This linear pixel dimension is squared to yield the pixel area in mm^2. The
volume of the voxel may be calculated by multiplying the pixel area by the section width

step 1. 44 cm/ 512 =0.0859

step 2. 0.0859*2.5 mm = 0.2148

step 3. move the decimal point =2.15 mm^3



For a particular CT scanner's beam quality, the linear attenuation coefficient for water is 0.20 cm-1
and for a certain tumor is 0.21 cm-1. What is the CT number of the tumor? - Correct Answer
Equation (.21-.20/.21) × 1000= 50



A CT system measures the average linear attenuation coefficient of a voxel of tissue to be 0.189. The
linear coefficient of water for this scanner is 0.181. The CT number assigned to the pixel representing
this tissue is - Correct Answer 44 HU

use equation above



A CT scanner capable of producing an image that is a perfect reproduction of the actual anatomic
section is said to have an MTF modulator transfer function of - Correct Answer 1

, For an increase from 200 mA to 400 mA in a CT exam, the result would be to - Correct Answer
increase low contrast resolution



The major controlling factor of exam quality for coronary CTA is - Correct Answer patients heart
rate... 65-70 beats per minute yield the best results



What is the atomic number of xenon gas? - Correct Answer 54



The exaggeration of displayed calcification within the coronary arteries during cardiac MDCT study is
referred to as - Correct Answer blooming

- the potential overestimation of vessel calcification due to partial volume artifact



a wide window setting (1500) or improving spatial resolution could help mitigate this effect



Which of the following section widths would cause the greatest amount of partial volume averaging



A. 1 mm

B. 3 mm

C. 5 mm

D. 10 mm - Correct Answer D. 10 mm



- Large section widths result in long voxel lengths with possibly several tissue types accounted for
within the voxel. When a CT number is assigned to the representative pixel, the density of all the
tissue types is averaged, yielding one attenuation coefficient. Narrow section widths tend to reduce
partial volume effect



What reduces partial volume effect? - Correct Answer narrow section widths



Patient is having a severe vagal reaction to contrast including brachycardia and hypotension.. what
should be done? - Correct Answer Iv fluids to raise blood pressure

atrophine administration to block vagal stimulation of the heart.



What type of reconstruction technique was used in the first CT scanners? - Correct Answer Iterative
form of reconstruction

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Winfred West Virgina University
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
763
Miembro desde
3 año
Número de seguidores
473
Documentos
7414
Última venta
1 día hace
StudySmart

Revising without a good structure can be so frustrating but with StudySmart you are able to get revision questions, summary notes and exams to help you pass with flying colors

3.9

158 reseñas

5
78
4
28
3
27
2
8
1
17

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes