Endoscope Reprocessing Manual Chapters 1 – 15 Verified Solutions 1. True or False: Manual cleaning should start right after pre-cleaning. - Answer: False 2. What term describes reprocessing that occurs more than one hour after the endoscope has been utilized? - Answer: Delayed processing. 3. When manually cleaning endoscopes, when should the cleaning solution be changed? - Answer: For each individual endoscope. 4. True or False: Using detergents that generate excessive foam can hinder fluid contact with the endoscope’s surface. - Answer: True 5. After rinsing the endoscope, what should be done to the inner channels before disinfection? - Answer: They should be purged with air. 6. How should water bottles be cleaned? - Answer: According to the manufacturer’s instructions. 7. True or False: Testing the effectiveness of the manual cleaning process should be conducted at least weekly, but daily is preferable. - Answer: True 8. True or False: Automated cleaning is the most crucial step in eliminating microbial contamination from flexible endoscopes. - Answer: False 9. What must be done before placing an endoscope into automated reprocessing equipment? - Answer: Thorough manual cleaning must be performed. ️ 10. How does the U.S. Food and Drug Administration (FDA) define validation? - Answer: Validation is establishing, through objective evidence, that a process consistently yields a result or product that meets predetermined specifications. 11. What are the seven general steps for manually cleaning flexible endoscopes? 1. Submerge the endoscope completely in a detergent/enzymatic solution. 2. Manually clean all internal and external surfaces, including brushing all internal channels that can be cleaned. 3. Attach appropriate cleaning adapters following the endoscope manufacturer’s instructions. 4. Flush each internal channel with detergent or enzymatic solution. 5. Soak in detergent/enzymatic solution for the recommended duration as per the manufacturer’s guidelines. 6. Rinse and submerge the endoscope in clean water; flush the channels. 7. Remove water from the channels by flushing them with air. 12. What should cleaning verification of flexible and semi-rigid endoscopes entail? 1. Visual inspection alongside other verifications to assess both external surfaces and internal channels. 2. Testing the effectiveness of mechanical cleaning equipment. 3. Monitoring key cleaning parameters. 13. What are the risks associated with delayed processing of endoscopes? - Answer: Delayed processing allows biofilm formation and soil to dry, making it more challenging to clean the endoscope effectively. 14. What federal agency is responsible for health promotion and prevention activities in the U.S., which also aims to enhance public health? - Answer: Centers for Disease Control and Prevention (CDC), established in 1946 and based in Atlanta, GA. 15. Which type of cleaning brush minimizes the risk of cross-contamination most effectively? - Answer: Disposable brushes. 16. What does the term 'distal' refer to in medical terminology? - Answer: It refers to the end of an item that is farthest from the point of origin; for example, the distal end of the femur is closest to the knee. 17. What are the three main objectives when transporting contaminated endoscopes? 1. Deliver the endoscope promptly. 2. Prevent cross-contamination during transport. 3. Protect the endoscope from damage. 18. What is the risk of a flexible endoscope that has not undergone leak testing? 1. Damaged endoscopes are susceptible to fluid invasion. 2. Unnoticed damage can hinder future procedures. 19. What is the term for fluid invading internal sections of an endoscope, leading to damage? - Answer: Fluid invasion. 20. What are the eight steps for conducting leak testing on an endoscope? 1. Inspect for tears and damage. 2. Remove suction, air, and water valves. 3. Connect the endoscope to the leak test device. 4. Pressurize, submerging the distal portion; flex, submerge, and inspect the control head. 5. Look for bubbles and signs of damage. 6. Remove the endoscope from water and drain it. 7. Release the pressure from the endoscope. 8. Disconnect from the leak tester. 21. What enzyme helps break down fatty deposits, such as bone marrow and adipose tissue? - Answer: Lipase. 22. What enzyme catalyzes the change of starch? - Answer: Amylase. 23. True or False: Pre-cleaning at the point of use reduces the chance of biofilm formation. - Answer: True 24. True or False: Pre-cleaning at the point of use should happen before the endoscope is detached from the power source. - Answer: True

Mostrar más Leer menos
Institución
Endoscope Reprocessing Manual Chapters 1 – 15 Veri
Grado
Endoscope Reprocessing Manual Chapters 1 – 15 Veri











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Endoscope Reprocessing Manual Chapters 1 – 15 Veri
Grado
Endoscope Reprocessing Manual Chapters 1 – 15 Veri

Información del documento

Subido en
14 de agosto de 2024
Número de páginas
89
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

Endoscope Reprocessing Manual Chapters 1 – 15 Verified Solutions


1. True or False: Manual cleaning should start right after pre-cleaning.

- Answer: False



2. What term describes reprocessing that occurs more than one hour after the endoscope has been
utilized?

- Answer: Delayed processing.



3. When manually cleaning endoscopes, when should the cleaning solution be changed?

- Answer: For each individual endoscope.



4. True or False: Using detergents that generate excessive foam can hinder fluid contact with the
endoscope’s surface.

- Answer: True



5. After rinsing the endoscope, what should be done to the inner channels before disinfection?

- Answer: They should be purged with air.



6. How should water bottles be cleaned?

- Answer: According to the manufacturer’s instructions.



7. True or False: Testing the effectiveness of the manual cleaning process should be conducted at least
weekly, but daily is preferable.

- Answer: True



8. True or False: Automated cleaning is the most crucial step in eliminating microbial contamination
from flexible endoscopes.

- Answer: False

,9. What must be done before placing an endoscope into automated reprocessing equipment?

- Answer: Thorough manual cleaning must be performed. ✔️



10. How does the U.S. Food and Drug Administration (FDA) define validation?

- Answer: Validation is establishing, through objective evidence, that a process consistently yields a
result or product that meets predetermined specifications.



11. What are the seven general steps for manually cleaning flexible endoscopes?

1. Submerge the endoscope completely in a detergent/enzymatic solution.

2. Manually clean all internal and external surfaces, including brushing all internal channels that can
be cleaned.

3. Attach appropriate cleaning adapters following the endoscope manufacturer’s instructions.

4. Flush each internal channel with detergent or enzymatic solution.

5. Soak in detergent/enzymatic solution for the recommended duration as per the manufacturer’s
guidelines.

6. Rinse and submerge the endoscope in clean water; flush the channels.

7. Remove water from the channels by flushing them with air.



12. What should cleaning verification of flexible and semi-rigid endoscopes entail?

1. Visual inspection alongside other verifications to assess both external surfaces and internal
channels.

2. Testing the effectiveness of mechanical cleaning equipment.

3. Monitoring key cleaning parameters.



13. What are the risks associated with delayed processing of endoscopes?

- Answer: Delayed processing allows biofilm formation and soil to dry, making it more challenging to
clean the endoscope effectively.



14. What federal agency is responsible for health promotion and prevention activities in the U.S., which
also aims to enhance public health?

, - Answer: Centers for Disease Control and Prevention (CDC), established in 1946 and based in Atlanta,
GA.



15. Which type of cleaning brush minimizes the risk of cross-contamination most effectively?

- Answer: Disposable brushes.



16. What does the term 'distal' refer to in medical terminology?

- Answer: It refers to the end of an item that is farthest from the point of origin; for example, the
distal end of the femur is closest to the knee.



17. What are the three main objectives when transporting contaminated endoscopes?

1. Deliver the endoscope promptly.

2. Prevent cross-contamination during transport.

3. Protect the endoscope from damage.



18. What is the risk of a flexible endoscope that has not undergone leak testing?

1. Damaged endoscopes are susceptible to fluid invasion.

2. Unnoticed damage can hinder future procedures.



19. What is the term for fluid invading internal sections of an endoscope, leading to damage?

- Answer: Fluid invasion.



20. What are the eight steps for conducting leak testing on an endoscope?

1. Inspect for tears and damage.

2. Remove suction, air, and water valves.

3. Connect the endoscope to the leak test device.

4. Pressurize, submerging the distal portion; flex, submerge, and inspect the control head.

5. Look for bubbles and signs of damage.

6. Remove the endoscope from water and drain it.

, 7. Release the pressure from the endoscope.

8. Disconnect from the leak tester.



21. What enzyme helps break down fatty deposits, such as bone marrow and adipose tissue?

- Answer: Lipase.



22. What enzyme catalyzes the change of starch?

- Answer: Amylase.



23. True or False: Pre-cleaning at the point of use reduces the chance of biofilm formation.

- Answer: True



24. True or False: Pre-cleaning at the point of use should happen before the endoscope is detached from
the power source.

- Answer: True



25. What is the first action in point-of-use pre-cleaning after removing the endoscope from the patient?

- Answer: Remove any gross soil.



26. When placing the pre-cleaned endoscope in a container for transport, should all accessories used
during the procedure be included?

- Answer: False



27. What is the primary objective of leak testing?

- Answer: To detect any damage present on the interior and exterior of the endoscope.



The endoscope can be returned to circulation to be used for surgery if the leakage is very minimal after
leak testing

false

Pre cleaning at the point of use increase the likelihood of biofilm formation

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
CertifiedGrades Chamberlain College Of Nursing
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
141
Miembro desde
2 año
Número de seguidores
61
Documentos
8748
Última venta
1 mes hace
High Scores

Hi there! Welcome to my online tutoring store, your ultimate destination for A+ rated educational resources! My meticulously curated collection of documents is designed to support your learning journey. Each resource has been carefully revised and verified to ensure top-notch quality, empowering you to excel academically. Feel free to reach out to consult with me on any subject matter—I'm here to help you thrive!

3.9

38 reseñas

5
21
4
6
3
2
2
3
1
6

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes