NICET III – Fire Stopping Study Review Practice Test. What is firestopping? - CORRECT ANSWER A process whereby certain materials, some of them specially manufactured, are used to resit (or stop) the spread of fire and its byproducts through openings made to accommodate penetrations in fire-rated walls, floors, and floor/ceiling assemblies. ....International Firestop Council Balanced approach to Fire Protection - CORRECT ANSWER Detection - Containment - Suppression Compartmentation (Fire compartments) - CORRECT ANSWER The spread of fire can be restricted by dividing a building into separate compartments with fire-resisting walls and floors, thereby increasing the availability of escape routes for occupants. What is the leading killer in fires? - CORRECT ANSWER smoke and toxic gasses (prodcuts of combustion) Intumescence - CORRECT ANSWER The ability of firestop material to swell, enlarge, or expand under heat conditions. The intumescing action seals and stops the spread of flames and smoke for penetrations that melt of change shape in a fire (e.g. plastic pipe) Typical firestop products - CORRECT ANSWER one-part sealants (caulks), putty, cementitious mortars and grouts, sprays (coatings), intumescent wraps, pillows bags or blocks, mechanical devices Types of firestop systems - CORRECT ANSWER • Through penetrations • Membrane penetrations • Fire resistive construction joints • Perimeter joints Through-penetration firestop system - CORRECT ANSWER consists of a fire rated wall or floor, a penetrating item (pipe, cable, conduit, etc) and the firestop material Tests for Through-Penetration Firestops - CORRECT ANSWER ASTM E814 / UL 1479 • F-Rating. Flame does not pass through for test duration • T-Rating. The time by which the non-fireside reaches approximately 400°F (325 above ambient) • L-Rating (optional). Amount of air leakage through the FS system at ambient and 400°F. Determines the system's ability to restrict the movement of smoke, measured in CFM/. The lower the number the better Factors affecting Through-Penetration firestop performance - CORRECT ANSWER Through penetrations: - types of penetrating item(s) - size of penetrating item(s) - percent fill (cables) - annular space - fire severity and duration - floor or wall construction type - floor or wall thickness - stud width for gypsum wall assemblies drywall tape vs. firestop sealant - CORRECT ANSWER - tape & mud will not withstand the effects of fire - the tape and mud may burn away leaving an unsealed opening in just minutes Membrane Penetration - CORRECT ANSWER Membrane Penetration: An opening made through one side (wall, floor, ceiling membrane) of an assembly Membrane Penetration Firestop - CORRECT ANSWER Membrane Penetration Firestop: A material, device or construction installed to resist, for a prescribed time period, the passage of flame and heat through openings in a protective membrane in order to accommodate cables, cable trays, conduit, tubing, pipes or similar items Fire Rated Joint System - CORRECT ANSWER Fire Rated Joint System:

Mostrar más Leer menos
Institución
Nicet
Grado
Nicet

Vista previa del contenido

NICET III – Fire Stopping Study Review
Practice Test.

What is firestopping? - CORRECT ANSWER A process whereby certain materials, some of them specially
manufactured, are used to resit (or stop) the spread of fire and its byproducts through openings made
to accommodate penetrations in fire-rated walls, floors, and floor/ceiling assemblies. ....International
Firestop Council



Balanced approach to Fire Protection - CORRECT ANSWER Detection - Containment - Suppression



Compartmentation (Fire compartments) - CORRECT ANSWER The spread of fire can be restricted by
dividing a building into separate compartments with fire-resisting walls and floors, thereby increasing
the availability of escape routes for occupants.



What is the leading killer in fires? - CORRECT ANSWER smoke and toxic gasses (prodcuts of combustion)



Intumescence - CORRECT ANSWER The ability of firestop material to swell, enlarge, or expand under
heat conditions. The intumescing action seals and stops the spread of flames and smoke for
penetrations that melt of change shape in a fire (e.g. plastic pipe)



Typical firestop products - CORRECT ANSWER one-part sealants (caulks), putty, cementitious mortars
and grouts, sprays (coatings), intumescent wraps, pillows bags or blocks, mechanical devices



Types of firestop systems - CORRECT ANSWER • Through penetrations

• Membrane penetrations

• Fire resistive construction joints

• Perimeter joints



Through-penetration firestop system - CORRECT ANSWER consists of a fire rated wall or floor, a
penetrating item (pipe, cable, conduit, etc) and the firestop material

, Tests for Through-Penetration Firestops - CORRECT ANSWER ASTM E814 / UL 1479

• F-Rating. Flame does not pass through for test duration

• T-Rating. The time by which the non-fireside reaches approximately 400°F (325 above ambient)

• L-Rating (optional). Amount of air leakage through the FS system at ambient and 400°F. Determines
the system's ability to restrict the movement of smoke, measured in CFM/sq.ft. The lower the number
the better



Factors affecting Through-Penetration firestop performance - CORRECT ANSWER Through penetrations:

- types of penetrating item(s)

- size of penetrating item(s)

- percent fill (cables)

- annular space

- fire severity and duration

- floor or wall construction type

- floor or wall thickness

- stud width for gypsum wall assemblies



drywall tape vs. firestop sealant - CORRECT ANSWER - tape & mud will not withstand the effects of fire

- the tape and mud may burn away leaving an unsealed opening in just minutes



Membrane Penetration - CORRECT ANSWER Membrane Penetration:

An opening made through one side (wall, floor, ceiling membrane) of an assembly



Membrane Penetration Firestop - CORRECT ANSWER Membrane Penetration Firestop:

A material, device or construction installed to resist, for a prescribed time period, the passage of flame
and heat through openings in a protective membrane in order to accommodate cables, cable trays,
conduit, tubing, pipes or similar items



Fire Rated Joint System - CORRECT ANSWER Fire Rated Joint System:

Escuela, estudio y materia

Institución
Nicet
Grado
Nicet

Información del documento

Subido en
4 de agosto de 2024
Número de páginas
7
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

  • nicet

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Nursewendo st georges london
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
63
Miembro desde
2 año
Número de seguidores
20
Documentos
4981
Última venta
3 semanas hace
EXAMS FOR TESTBANKS, PACKAGE DEALS,SINGLE DOCUMENTS ETC.

ARE YOU LOOKING FOR STUDY MATERIALS FOR YOUR EXAMS ??? LOOK NO FURTHER,WE DEAL WITH ALL COURSES E.G TESTBANK,PACKAGE DEALS,SINGLE DOCUMENTS,AQA E.T.C. DO NOT WORRY I WILL SORT YOU OUT WITH ALL YOUR STUDY GUIDES WITH AN A+ RESULT . BEST OF LUCK.!!

4.0

18 reseñas

5
11
4
1
3
3
2
1
1
2

Documentos populares

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes