Fire Officer final
Part of the ___ percent reduction in the aviation industry's accident rate is attributed to
the development, refinement and system wide adoption of crew resource management.
- ANS-80
Duponts dirty dozen are a comprehensive list of reasons and ways that humans make
mistakes - ANS-lack of communication, complacency, lack of knowledge, distraction,
lack of teamwork, fatigue, lack of resources, pressure, lack of assertiveness, stress,
lack of awareness, norms.
Dr. James reasons cites 2 reasons explaining why holes appear in the layers of defense
- ANS-active failures and latent conditions.
Self assessment should consider 4 critical areas - ANS-physical condition, mental
condition, attitude, understanding human behavior
NFPA ___ standard for professional qualifications for fire investigator - ANS-1033
3 methods for heat transfer - ANS-conduction, convection, radiation
Fire officials are charged not only with extinguishing fires but with finding their cause
supreme court ___ ___ - ANS-michigan v tyler 1978
The fire officer must consider 3 types of evidence - ANS-demonstrative, documentary
and testimonial evidence
NFPA___ guide for fire and explosion investigations - ANS-921
The first step in fire cause determination is to identify the ___ ___ ___ - ANS-point of
origin.
4 sources for determining the point of origin requires the analysis of information - ANS-1
fire patterns, observations by witnesses, physics and chemistry of fire initiation, noting
the location where electrical arcing has caused damage.
Cause determination can be approached 3 step process - ANS-determine source of
ignition, determine the fuel that was ignited, determine the circumstances
,Competent ignition source has 3 components - ANS-generation, transmission, heating.
__ percent of vehicle fires were caused by mechanical failure or malfunction. - ANS-47
4 fire cause classifications - ANS-accidental, nature, incendiary, undetermined
The most common electrical fire scenario is ___ ___ __ ___ - ANS-misuse by the
occupant.
National statistics indicate that 1 in every ___ fires is of incendiary origin. - ANS-4
By 1915 ASTM E __, standard test methods for fire tests of building construction and
materials - ANS-119
Stephen Kerber wrote - ANS-analysis of changing residential fire dynamics and its
implications on firefighter operational timeframes
The only way to go from a ventilation limited to a ___ ___ fire is through application of
water before vertical ventilation - ANS-fuel limited
Softening the target by applying ___to___ seconds of water into the compartment
dramatically reduces fire development and improves condition - ANS-30 to 90
The inherent risks associated with emergency operations demand ___ supervision at all
times - ANS-close
NFPA ___ standard for the organization and deployment of the fire suppression
operations, emergency medical operations and special operations to the public by
volunteer fire departments - ANS-1720
___ is one of the most significant factors in size up - ANS-visualization
in 1940 ___ authored fundamentals of fire tactics - ANS-Chief Lloyd Layman
Laymans 5 step process for analyzing emergency situations - ANS-facts,probabilities,
situation, decision, plan of operation
The situation assessment involved 3 considerations the 1st consideration is -
ANS-whether the resources on scene and en route will be sufficient to handle the
incident.
,The 2nd consideration in situation assessment is the ___ ___ and limitations of the
responding resources in relation to the problem - ANS-specific capabilities.
The ___ step in laymans size up procedure is making fire attack decisions - ANS-4th
The national fire academy has developed a size up system that includes 3 phases -
ANS-preincident information, initial size up, ongoing size up
The 2nd phase of the size up begins on receipt of an alarm 3 questions need to be
answered - ANS-what, where and how do i control it.
The 2 major components to IAP - ANS-1 determination of the appropriate strategy to
mitigate an incident,2 development of tactics to execute the strategy
RECEO VS is an acronym that covers the critical factors in developing a strategy -
ANS-Rescue, exposures, confinement, extinguishment, overhaul, ventilation, salvage.
The best method of protecting the occupants from harm is to ___ the fire quickly -
ANS-extinguish
NFPA ___ standard for training fire service rapid intervention crews - ANS-1407
Tactical priorities are subdivided into ___ and assigned to companies - ANS-tasks
The method most commonly used by a fire officer to activate local emergency plan is to
notify the ___ ___ - ANS-dispatch center
The 13R system does not protect the ___ ___ or the void spaces - ANS-attic area
The IAFC board of directors endorsed ___ __ _____ in August 2011 as "best safety
practice model procedures." - ANS-Rules of Engagement
Covering high risk operations in a high hazard environment required that the rules meet
the following criteria(4) - ANS-1 be a short, specific set of bullet points 2 be easily taught
and remembered 3 define critical risk issues 4 define "go" and "no GO" situations
More that __ ___ of the disoriented firefighter deaths occurred in enclosed structures. -
ANS-3/4
, What are the 11 rules of engagement for structural firefighting - ANS-1 size up your
tactical area of operation 2 determine the occupant survival profile 3 do not risk your life
for lives or property that cannot be saved 4 extend limited risk to protect savable
property 5 extend vigilant and measured risk to protect and rescue savable lives. 6 go in
together, stay together, come out together. 7 maintain continuous awareness of your air
supply, situation, location, and fire conditions 8 Constantly monitor fire ground
communications for critical radio reports 9 you are required to report unsafe practices or
conditions that can harm you. Stop evaluate, and decide 10 you are required to
abandon your position and retreat before deteriorating conditions can harm you 11
declare a mayday as soon as you think you are in danger.
NFPA 1404 - ANS-Standard for Fire Service Respiratory Protection Training
NFPA 1500 requires standardized IDLH exiting be practices when the SCBA cylinder
reaches a level of ___L or more. - ANS-600L
NFPA 1852 - ANS-Standard on Selection, care, and Maintenance of Open circuit self
contained breathing apparatus.
Chief Paul Lesage 2009 determined __% of errors on the fire ground happen when
individuals fail to intervene in known or observed unsafe situations. - ANS-74
10 reasons firefighter's fail to or delay to declare a mayday - ANS-1 temporal distortion
2 reluctance to relinquish control of one's situations 3 channeled attention ( continuing
with a previous selected course of action because other, more significant information is
not perceived) 4 loss of situational awareness 5 fear of the unknown 6 fear of retribution
7 lack of procedural knowledge 8 attempting to fix the problems 9 pride 10 denial
Crew integrity - ANS-a system in which firefighter's stay together as a team of two or
more members.
Enclosed structure - ANS-a building that lacks Windows or doors of sufficient number
and size to provide for prompt ventilation and emergency evacuation
Limited - ANS-At the point, edge, or line beyond which something cannot or may not
proceed; confined or restricted within certain limits.
Mayday - ANS-A situation where a fire fighter is experiencing a life threatening
emergency
Part of the ___ percent reduction in the aviation industry's accident rate is attributed to
the development, refinement and system wide adoption of crew resource management.
- ANS-80
Duponts dirty dozen are a comprehensive list of reasons and ways that humans make
mistakes - ANS-lack of communication, complacency, lack of knowledge, distraction,
lack of teamwork, fatigue, lack of resources, pressure, lack of assertiveness, stress,
lack of awareness, norms.
Dr. James reasons cites 2 reasons explaining why holes appear in the layers of defense
- ANS-active failures and latent conditions.
Self assessment should consider 4 critical areas - ANS-physical condition, mental
condition, attitude, understanding human behavior
NFPA ___ standard for professional qualifications for fire investigator - ANS-1033
3 methods for heat transfer - ANS-conduction, convection, radiation
Fire officials are charged not only with extinguishing fires but with finding their cause
supreme court ___ ___ - ANS-michigan v tyler 1978
The fire officer must consider 3 types of evidence - ANS-demonstrative, documentary
and testimonial evidence
NFPA___ guide for fire and explosion investigations - ANS-921
The first step in fire cause determination is to identify the ___ ___ ___ - ANS-point of
origin.
4 sources for determining the point of origin requires the analysis of information - ANS-1
fire patterns, observations by witnesses, physics and chemistry of fire initiation, noting
the location where electrical arcing has caused damage.
Cause determination can be approached 3 step process - ANS-determine source of
ignition, determine the fuel that was ignited, determine the circumstances
,Competent ignition source has 3 components - ANS-generation, transmission, heating.
__ percent of vehicle fires were caused by mechanical failure or malfunction. - ANS-47
4 fire cause classifications - ANS-accidental, nature, incendiary, undetermined
The most common electrical fire scenario is ___ ___ __ ___ - ANS-misuse by the
occupant.
National statistics indicate that 1 in every ___ fires is of incendiary origin. - ANS-4
By 1915 ASTM E __, standard test methods for fire tests of building construction and
materials - ANS-119
Stephen Kerber wrote - ANS-analysis of changing residential fire dynamics and its
implications on firefighter operational timeframes
The only way to go from a ventilation limited to a ___ ___ fire is through application of
water before vertical ventilation - ANS-fuel limited
Softening the target by applying ___to___ seconds of water into the compartment
dramatically reduces fire development and improves condition - ANS-30 to 90
The inherent risks associated with emergency operations demand ___ supervision at all
times - ANS-close
NFPA ___ standard for the organization and deployment of the fire suppression
operations, emergency medical operations and special operations to the public by
volunteer fire departments - ANS-1720
___ is one of the most significant factors in size up - ANS-visualization
in 1940 ___ authored fundamentals of fire tactics - ANS-Chief Lloyd Layman
Laymans 5 step process for analyzing emergency situations - ANS-facts,probabilities,
situation, decision, plan of operation
The situation assessment involved 3 considerations the 1st consideration is -
ANS-whether the resources on scene and en route will be sufficient to handle the
incident.
,The 2nd consideration in situation assessment is the ___ ___ and limitations of the
responding resources in relation to the problem - ANS-specific capabilities.
The ___ step in laymans size up procedure is making fire attack decisions - ANS-4th
The national fire academy has developed a size up system that includes 3 phases -
ANS-preincident information, initial size up, ongoing size up
The 2nd phase of the size up begins on receipt of an alarm 3 questions need to be
answered - ANS-what, where and how do i control it.
The 2 major components to IAP - ANS-1 determination of the appropriate strategy to
mitigate an incident,2 development of tactics to execute the strategy
RECEO VS is an acronym that covers the critical factors in developing a strategy -
ANS-Rescue, exposures, confinement, extinguishment, overhaul, ventilation, salvage.
The best method of protecting the occupants from harm is to ___ the fire quickly -
ANS-extinguish
NFPA ___ standard for training fire service rapid intervention crews - ANS-1407
Tactical priorities are subdivided into ___ and assigned to companies - ANS-tasks
The method most commonly used by a fire officer to activate local emergency plan is to
notify the ___ ___ - ANS-dispatch center
The 13R system does not protect the ___ ___ or the void spaces - ANS-attic area
The IAFC board of directors endorsed ___ __ _____ in August 2011 as "best safety
practice model procedures." - ANS-Rules of Engagement
Covering high risk operations in a high hazard environment required that the rules meet
the following criteria(4) - ANS-1 be a short, specific set of bullet points 2 be easily taught
and remembered 3 define critical risk issues 4 define "go" and "no GO" situations
More that __ ___ of the disoriented firefighter deaths occurred in enclosed structures. -
ANS-3/4
, What are the 11 rules of engagement for structural firefighting - ANS-1 size up your
tactical area of operation 2 determine the occupant survival profile 3 do not risk your life
for lives or property that cannot be saved 4 extend limited risk to protect savable
property 5 extend vigilant and measured risk to protect and rescue savable lives. 6 go in
together, stay together, come out together. 7 maintain continuous awareness of your air
supply, situation, location, and fire conditions 8 Constantly monitor fire ground
communications for critical radio reports 9 you are required to report unsafe practices or
conditions that can harm you. Stop evaluate, and decide 10 you are required to
abandon your position and retreat before deteriorating conditions can harm you 11
declare a mayday as soon as you think you are in danger.
NFPA 1404 - ANS-Standard for Fire Service Respiratory Protection Training
NFPA 1500 requires standardized IDLH exiting be practices when the SCBA cylinder
reaches a level of ___L or more. - ANS-600L
NFPA 1852 - ANS-Standard on Selection, care, and Maintenance of Open circuit self
contained breathing apparatus.
Chief Paul Lesage 2009 determined __% of errors on the fire ground happen when
individuals fail to intervene in known or observed unsafe situations. - ANS-74
10 reasons firefighter's fail to or delay to declare a mayday - ANS-1 temporal distortion
2 reluctance to relinquish control of one's situations 3 channeled attention ( continuing
with a previous selected course of action because other, more significant information is
not perceived) 4 loss of situational awareness 5 fear of the unknown 6 fear of retribution
7 lack of procedural knowledge 8 attempting to fix the problems 9 pride 10 denial
Crew integrity - ANS-a system in which firefighter's stay together as a team of two or
more members.
Enclosed structure - ANS-a building that lacks Windows or doors of sufficient number
and size to provide for prompt ventilation and emergency evacuation
Limited - ANS-At the point, edge, or line beyond which something cannot or may not
proceed; confined or restricted within certain limits.
Mayday - ANS-A situation where a fire fighter is experiencing a life threatening
emergency