NHA NOW EKG Technician Practice Test Grade A+ Which of the following EKG machine functions should an EKG technician use to control and regulate the height of EKG waveforms on the tracing? a. Speed b. Output display c. Artifact filter d. Gain - Correct Answer d. Gain Which of the following methods should a EKG technician use when removing hair from electrode placement sites for telemetry monitoring? a. Dry shave b. Wet shave c. Tape d. Clippers - Correct Answer d. Clippers An EKG technician notes periods of sinus arrest on a patient's EKG tracing. The technician should consider the sinus arrest to be a medical emergency when the arrest reaches which of the following durations? a. 6 sec b. 4 sec c. 3 sec d. 1 sec - Correct Answer a. 6 sec Which of the following lead groups are bipolar leads? a. Leads aVR, aVL, and aVF b. Leads I, II, and III c. Leads V1, V2, and V3 d. Leads V4, V5, and V6 - Correct Answer b. Leads I, II, III An EKG technician is performing a second standard 12-lead EKG on a patient immediately following the first test. For which of the following reasons should the technician recognize that resting tab electrodes should not be used for more than two consecutive EKG tracings? a. The electrodes cannot conduct the signal after two EKG tracings b. The electrodes will not conduct accurately after two EKG tracings c. The electrodes need to be cleaned after two EKG tracings d. The electrodes will not re-adhere to the skin after being removed between tracings - Correct Answer b. The electrodes will not conduct accurately after two EKG tracings In which of the following locations should an EKG technician place the electrode for leavd V5? a. On the left midaxillary line, horizontal to lead V4 b. On the left anterior axillary line, hori

Mostrar más Leer menos
Institución
Grado

Vista previa del contenido

NHA NOW EKG Technician Practice Test
Grade A+
Which of the following EKG machine functions should an EKG technician use to control
and regulate the height of EKG waveforms on the tracing?
a. Speed
b. Output display
c. Artifact filter
d. Gain - Correct Answer d. Gain

Which of the following methods should a EKG technician use when removing hair from
electrode placement sites for telemetry monitoring?
a. Dry shave
b. Wet shave
c. Tape
d. Clippers - Correct Answer d. Clippers

An EKG technician notes periods of sinus arrest on a patient's EKG tracing. The
technician should consider the sinus arrest to be a medical emergency when the arrest
reaches which of the following durations?
a. 6 sec
b. 4 sec
c. 3 sec
d. 1 sec - Correct Answer a. 6 sec

Which of the following lead groups are bipolar leads?
a. Leads aVR, aVL, and aVF
b. Leads I, II, and III
c. Leads V1, V2, and V3
d. Leads V4, V5, and V6 - Correct Answer b. Leads I, II, III

An EKG technician is performing a second standard 12-lead EKG on a patient
immediately following the first test. For which of the following reasons should the
technician recognize that resting tab electrodes should not be used for more than two
consecutive EKG tracings?
a. The electrodes cannot conduct the signal after two EKG tracings
b. The electrodes will not conduct accurately after two EKG tracings
c. The electrodes need to be cleaned after two EKG tracings
d. The electrodes will not re-adhere to the skin after being removed between tracings -
Correct Answer b. The electrodes will not conduct accurately after two EKG tracings

In which of the following locations should an EKG technician place the electrode for
leavd V5?
a. On the left midaxillary line, horizontal to lead V4
b. On the left anterior axillary line, horizontal to lead V4

,c. On the left midclavicular line, fifth intercostal space
d. On the right margin of the sternum, fourth intercostal space - Correct Answer b. On
the left anterior axillary line, horizontal to lead V4

An EKG technician is working with a patient who has a below-the-knee amputation of
the left leg. In which of the following locations should the technician place the right leg
electrode?
a. On the lower right foot
b. On the lower right abdomen
c. On the lower left torso
d. On the lower right leg - Correct Answer b. On the lower right abdomen

Which of the following methods should an EKG technician use to store electrodes when
not in use?
a. Loose in the EKG cart
b. In a folded paper bag
c. In an open plastic bag
d. In the original, foil-lined packaging - Correct Answer d. In the original, foil-lined
packaging

A serial EKG tracing shows a rhythm that does not match the last tracing that the EKG
technician performed. Which of the following actions should the technician take first?
a. Connect the patient to a different EKG machine.
b. Report the finding to the provider
c. Verify proper lead placement
d. Perform a maintenance check on the machine - Correct Answer c. Verify proper lead
placement

Which of the following statements made by an EKG technician correctly prepares the
patient for telemetry monitoring?
a. "I will clean your skin with an alcohol pad"
b. "You may feel a slight warming sensation after the electrodes are placed on the skin"
c. "A mild rash or skin redness should be expected around the electrodes after 24
hours."
d. "Electrodes will be replaced once per week while you're in the hospital." - Correct
Answer a. "I will clean your skin with an alcohol pad"

An EKG technician is performing a standard 12-lead EKG on a patient who is 4 years
old. In which of the following locations should the technician place the V6 electrodes?
a. Right midclavicular space
b. Left midclavicular space
c. Right midaxillary line
d. Left midaxillary line - Correct Answer d. Left midaxillary line

Which of the following sections of the EKG tracing should an EKG technician use to
measure the QRS complex?

, a. End of the Q wave to the beginning of the S wave
b. Beginning of the Q wave to the beginning of the S wave
c. End of the Q wave to the beginning of the T wave
d. Beginning of the Q wave to the end of the S wave - Correct Answer d. Beginning of
the Q wave to the end of the S wave

An EKG technician observes varying R-R intervals on an EKG for a 2-year-old patient.
Which of the following statements made by the technician would be correct?
a. "Irregular rhythms are rarely seen in children"
b. "This is life threatening. I must notify the physician immediately"
c. "The irregularity is normal and is a result of respiration"
d. "The rhythm is likely atrial fibrillation and requires elective cardioversion" - Correct
Answer c. "The irregularity is normal and is a result of respiration"

An EKG technician is recording a patient's radial pulse rate and finds the pulse to be
irregular. The provider then takes the patient's apical pulse. The technician should
recognize that which of the following locations is used for this assessment?
a. Between the larynx and the left sternocleidomastoid muscle
b. Between the fifth and sixth ribs, at the left midclavicular line
c. The antecubital aspect of the left or right elbow
d. The thumb side of the left wrist - Correct Answer b. Between the fifth and sixth ribs,
at the left midclavicular line

Which of the following descries a complete cardiac cycle in a healthy heart?
a. P wave, Q wave, and ST segment
b. P wave, QRS complex, and T wave
c. P wave, QRS complex, and QT interval
d. P wave, QRS complex, and P wave - Correct Answer b. P wave, QRS complex, and
T wave

An EKG technician is preparing to perform an EKG for a patient who does not speak the
same language as the technician. Which of the following actions hsould the technician
take to avoid miscommunication with the patient?
a. Have a member of the patient's family translate
b. Point and use other forms of nonverbal communication
c. Rely on materials printed in the patient's native language
d. Have a bilingual staff member translate - Correct Answer d. Have a bilingual staff
member translate

An EKG technician is instructing a patient about the use of a transtelephonic monitor
with loop memory. Which of the following instructions should the technician include?
a. "Press the record button on the device when you begin to feel dizzy or have chest
pain"
b. "Remove the monitor when connecting to the phone or internet to send the recording
to the central monitoring location"

Escuela, estudio y materia

Grado

Información del documento

Subido en
29 de mayo de 2024
Número de páginas
17
Escrito en
2023/2024
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$10.89
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
purityireri233 Harvard University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
55
Miembro desde
2 año
Número de seguidores
10
Documentos
1402
Última venta
3 semanas hace

3.7

15 reseñas

5
4
4
3
3
8
2
0
1
0

Documentos populares

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes