Blueprism - Browser Automaton
Launching and Attaching - answer-It can often be difficult to reliably launch and attach to Internet Explorer sessions due to a feature in IE that allows IE sessions to run in separate Windows processes which are spawned from a primary IE process. the main parent process is given the index of 0, whereas the first tab of the process is given the Child Index of 1. The Child Index parameter is specified in the attach action of a navigate stage. or as an alternative you can configure Internet Explorer to not create multiple processes. This is done by changing a registry setting, specifically the registry key: HKEY CURRENT USERSoftwareMicrosoftInternet ExplorerMain DWORD value called TabProcGrowth should be set to one of the following values: 0 (Zero) - This disables protected mode for IE Security Zones and tells Internet Explorer to open tabs and frames within the same process. 1 (One) - This leaves protected mode enabled, and ensures that all tabs in a given frame run in a single process. Note that this may require the use of process flow to launch and separately attach to the required IE instance. Two processes will still be created, one for the frame and one for all the tabs within that frame. Launch via Process Name - answer-using a built in Blue Prism utility called Utility - Environment. There is an action within this object called Start Process which takes the path of the application you would wish to start and any command line arguments. Application : Arguments : IMP you have to manually attach Spying Modes - answer-The three spying modes available for browser integration are Win32 mode, HTML mode and Active Accessibility mode. WIN 32 Mode - answer-Win32 mode will only work with Internet Explorer windows themselves, not with the web app within. This mode is particularly helpful for manipulating IE windows by performing actions such as Resize, Activate and Send Keys. It can also be used with Wait stages, for example, waiting for a window to appear on the screen. HTML Mode - answer-HTML mode will only recognise the HTML elements within the web app, nothing outside. AA - answer-Active Accessibility mode can detect a mixture of web app elements and Internet Explorer elements. If the standard HTML mode does not work, this mode often does. Get Table - answer-a table cannot be read into a Collection, it could be that the values held within the HTML code are not stored directly in table tags, because more HTML code is being held within the table cell. For
Información del documento
- Subido en
- 26 de mayo de 2024
- Número de páginas
- 4
- Escrito en
- 2023/2024
- Tipo
- Examen
- Contiene
- Preguntas y respuestas