NETA Level 2 Study Material Guide for 2024 Tested and Already Passed!!!
NETA Level 2 Study Material Guide for 2024 Tested and Already Passed!!! The state of charge of a lead acid battery is measured by which of the following: - CORRECT ANSWER-Hydrometer Temporary safety grounds: - CORRECT ANSWER-Are sized with consideration of available short circuit current and time duration Before personnel are allowed to operate a power circuit breaker they must first understand the ________ of the breaker. - CORRECT ANSWER-All the above Type MV is a single dielectric insulated cable rated _____ volts or higher. - CORRECT ANSWER-2001 Which of the following is LEAST likely to contain a blown fuse trip device? - CORRECT ANSWER-200 amp fused safety switch An accessory used to allow a circuit breaker to be remotely operated is called a/an _________. - CORRECT ANSWER-shunt trip Branch-circuit overcurrent devices in emergency circuits shall be accessible to ______ only. - CORRECT ANSWER-authorized persons In a wye connected system, without neutral grounding, zero sequence currents are: - CORRECT ANSWER-zero What are the three most common states for network protectors? - CORRECT ANSWER-automatic, closed, open Triangle NAB is as shown. If: AN = BN = 100 and BD = AD and N = 120°, then length BD is: - CORRECT ANSWER-86.7 Contactor coils are present in manual motor starters: - CORRECT ANSWER-false Which of the following is not a standard dc power source voltage? - CORRECT ANSWER-96 The wound-rotor induction motor is popular in industry because it has _____ starting torque and _____ starting current. - CORRECT ANSWER-high, low Multiphase delta-delta, 3-wire transformer secondary conductors are not considered to be protected by the transformer primary overcurrent protective device. - CORRECT ANSWER-false Why it is required to drain off the stored charge in a capacitor after the supply circuit has been opened. - CORRECT ANSWER-personnel safety Using the diagram above, identify a point that would not be energized if voltage was applied to the line bus. - CORRECT ANSWER-point 12 The size of the neutral conductor is determined by which of the following: - CORRECT ANSWER-unbalanced current The grounding conductor is one of the two conductors through which normal circuit current flows. - CORRECT ANSWER-false
Escuela, estudio y materia
- Institución
- Neta
- Grado
- Neta
Información del documento
- Subido en
- 24 de mayo de 2024
- Número de páginas
- 12
- Escrito en
- 2023/2024
- Tipo
- Examen
- Contiene
- Preguntas y respuestas
Temas
-
neta level 2 study material guide for 2024 tested
-
the state of charge of a lead acid battery is meas
-
before personnel are allowed to operate a power ci
-
what are the three most common states for netwo