Elevator Mechanic Questions and Answers 100% Solved correctly
ASME - Answer-American Society of Mechanical Engineers DOSH - Answer-Division of Occupational Safety and Health LADBS - Answer-Los Angeles Department of Building and Safety Alteration made to conveyance shall comply with ASME A17.1-204 Section - Answer-8.7 The seismic section of ASME A17.1-2004 and alterations made to conveyances must also comply with this section - Answer-8.4 What must be submitted to the applicable Division Elevator office prior to beginning construction or alterations on a conveyance Title 8 Sec 3000 - Answer-Letter of Intent When shall Category One Tests on conveyances be completed Title 8 Sec 3141.6 - Answer-Once every 12 months What shall be provided on all conveyances regardless of the existence of an emergency stop switch ASME A17.1-2004 2.27.1.2 - Answer-Audible signaling device When are Hoistway door unlocking devices on all conveyances required Title 8 Sec 3141.7 ASME A17.1-2004 2.12.6 - Answer-ProhibitedWhat section should Group IV platform lifts and stairway chairlifts shall comply with - Answer-ASME A18.1-2003 When setbacks or projections exceed this number of inches, occur in the enclosure wall, the top of the setback or projection shall be beveled at an angle not less than 75 degrees with the horizontal ASME A17.1-2004 2.1.6 - Answer-4 inches At what height shall the hoistway enclosure of a Group IV elevator be Unperforated ASME A17.1-2004 2.1.1.2.2 - Answer-79 inches For elevators installed after June 5, 1947, there shall be installed in the pit of each elevator where the pit extends below the sill of the pit access door a fixed vertical ladder. How many inches below the sill? ASME A17.1-2004 2.2.4.2 - Answer-35 inches On a Group IV elevator, what is the minimum pit lighting illumination that should be provided at the pit floor ASME A17.1-2004 2.2.5.1 - Answer-10 fc (foot candles) For Group IV elevators that are not fully enclosed, how high of protection should be provided on the hoistway sides that are located 59 inches or less from elevator equipment in areas accessible to other than elevator personnel ASME A17.1-2004 2.2.1.3 - Answer-94.5 inches Permanent means shall be provided to prevent the accumulation of what?, in the elevator pit ASME A17.1-2004 2.2.2.3 - Answer-WaterIn place of a sump pump, what else shall be provided on elevators equipped with Firefighters' Emergency Operation ASME A17.1-2004 2.2.2.5 - Answer-Drain On a Group IV elevator, how far shall a pit ladder extend no less than how many inches above the sill of the access door ASME A17.1-2004 2.2.4.2 - Answer-48 inches Where pit mounted counterweight buffers are used, a counterweight guard is not required when the bottom of the counterweight resting on its compressed buffer is how many inches or more above the pit floor ASME A17.1-2004 2.3.2.2 5.10.1.3.2 - Answer-84 inches
Escuela, estudio y materia
- Institución
- Elevator Mechanic
- Grado
- Elevator Mechanic
Información del documento
- Subido en
- 12 de mayo de 2024
- Número de páginas
- 31
- Escrito en
- 2023/2024
- Tipo
- Examen
- Contiene
- Preguntas y respuestas
Temas
Documento también disponible en un lote