1 FLORIDA FIRE INSPECTOR REVIEW QUESTIONS & ANSWERS , GRADED A+ passive - ✅✅ -Fire rated walls are examples of _____ fire protection features. used to clarify assembly - ✅✅ -What is an exploded Pictorial Drawing? pressure - ✅✅ -One unavoidable problem with standpipe systems is the variation of ____ with building heigh t. descriptive codes - ✅✅ -Traditional fire and building codes are called? a steep slope - ✅✅ -Contour line that are close together on a plan indicate _______? 300 ft - ✅✅ -At what height can water be effectively pumped from the ground level with adequate pressure? architects signature - ✅✅ -A set of architectural drawings must contain a __________ to be considered a valid set of plans. code - ✅✅ -A _______ is a collection or body of rules pertaining to one subject area such as buildings, fires, and motor v ehicles. >180 days - ✅✅ -Fire codes typically address membrane structures with a life of how many days? in the welding schedule - ✅✅ -Where are the notes placed for a welding symbol? spec buildings - ✅✅ -Buildings constructed without final occupancy in min d are called? plot - ✅✅ -A ________ plans shows the overall project layout including features such as building areas, location, setbacks, etc. as-built plans - ✅✅ -What term is used to define the final set of plans or drawings that are saved as a permanent record? hydraulic - ✅✅ -Contemporary Sprinkler systems are designed using ____________ calculations. mechanical - ✅✅ -What type of plan would a HVAC system be shown? Device designed to limit the standpipe pressure for 2 1/2 inch outlets when the pressure exceeds 175 PSI - ✅✅ -What is the purpose of a PRV? run - ✅✅ -Wiring is sometime referred to as a? 1 hour - ✅✅ -It is common for codes to require a __________ fire -resistive rating for corridor walls in health care facilities. concentrated load - ✅✅ -Any l oad that is applied at one point or over a small area such as a safe or heavy piece of equipment is considered a true - ✅✅ -True or Flase, Fire and emergency service plans examiner may not be involved in the review of structural plans. light hazard - ✅✅ -What type of occupancy is considered those in which the quantity or combustibility of the contents is low and heat -release rates expected are also low? load - ✅✅ -Any effect that a structure must be designed to prevent is best described as a ________? mech anical - ✅✅ -_________ plans show where plumbing systems and heating, ventilation and air conditioning systems. footing - ✅✅ -The purpose of the ___________ beneath the foundation is to distribute the buildings weight? torsional - ✅✅ -What type of force is produced in a structural member when it is twisted, creating shear stresses in the material? direct pressure load - ✅✅ -What type of load would the impact of wind against a buildings wall is known as? addressable - ✅✅ -An alarm system where each part of th e system has its own unique address and talks to the main control panel is known as? 75ft - ✅✅ -What is the maximum travel distance from any point in a structure to an extinguisher location? pictorial/rendering - ✅✅ -What type of drawing provides the most realistic view of how equipment looks as well as how it is connected? 5 min - ✅✅ -Fire alarms are required to have emergency power systems that may consist of storage batteries or a combination of an emergency generator and storage batteries. When an emerg ency generator is used, storage batteries capable of supplying the fire alarm system for? risers - ✅✅ -_____ is a term generally applied to vertical supply pipes used to supply water to the upper floors. stairwells - ✅✅ -Class 1 standpipe connections must be located in what part of the building? grounding - ✅✅ -What is the term used to describe equalizing static electrical charge between an object and the earth? annunciator panel - ✅✅ -An _____________ indicates where an alarm or other condition has origina ted on the fire alarm system. class 2 - ✅✅ -What class of standpipe is designed for use by either fire department personnel or building occupants? 100psi - ✅✅ -NFPA 14 requires a minimum residual pressure of ________ PSI at the most remote 2 1/2 " hose val ve for Class I and Class III standpipes. bonding - ✅✅ -What term is used to describe equalizing static electrical charges between two object such as a drum and container? 25ft - ✅✅ -Modern elevators that rise more than __________ feet are required to be eq uipped with a key operated manual recall or fireman's service systems. 175psi - ✅✅ -PRV devices typically limit the system pressure to a maximum of ________ to prevent damage to the system. 2 hours or 50ft from the building - ✅✅ -In high -rise structures, w hat is the minimum fire protection rating/separation for an indoor stationary fire -pump? 3% - ✅✅ -Gauges not accurate to within ____ of the full scale shall be recalibrated or replaced. datum - ✅✅ -A method to indicate the elevation of carious building fea tures above an established reference point is normally called a ______? protect community health & safety - ✅✅ -The most fundamental reason for requiring construction permits is? backflow prevention - ✅✅ -___________ on water supplies to fire protection sy stems is required to prevent potential contamination of domestic water by cross -connection to a non -domestic source.