Backflow Prevention Practice Exam 2024 Questions and Verified Answers.
Backflow Prevention Practice Exam 2024 Questions and Verified Answers. A backflow preventer creates a closed plumbing system that requires the installation of a(n) _____? A. Expansion tank B. Globe valve C. Pressure reducing valve D. Temperature and pressure relief valve E. Utility box key - ANSWER Expansion tank A barometric loop must be installed 35 ft (10.7 m) above the highest ____? A. Boiler B. Fixture outlet C. Gate valve D. Service connection E. Water meter - ANSWER Fixture outlet A check valve field test reported value of 0.8 psid (5.5 kPa) suggests _____? A. A passing check valve B. A broken or failed spring C. Debris in the check seat D. Disc softening or decay E. Low water pressure - ANSWER Disc softening or decay A common backflow preventer on a double-wall heat exchanger with Backflow Prevention Practice Exam 2024 Questions and Verified Answers leak detection is ____? A. An air-gap separation B. An atmospheric vacuum breaker C. A double check valve assembly D. A reduced pressure principle assembly E. Nothing - ANSWER Nothing A cross-connection may be a permanent piping arrangement or a(n) ____? A. Backflow preventer B. Church symbol C. OSHA hazardous area designation D. Railroad and highway intersection sign E. Temporary hose bibb connection - ANSWER Temporary hose bibb connection A deck-mounted atmospheric vacuum breaker's critical installation level is above the outlet usage by ___? A. 1 in. (2.5 cm) B. 3 in. (7.6 cm) C. 6 in. (15 cm) D. 12 in. (30 cm) E. 18 in. (46 cm) - ANSWER 1 in. (2.5 cm) A differential pressure gauge reading of 0.2 psid is represented on water column sight tube by _____? A. 1/16 in. (0.16 cm) B. 1/2 in. (1.3 cm) C. 2 in. (5.1 cm) D. 3.5 in. (8.9 cm) E. 5.5 in. (14 cm) - ANSWER 5.5 in. (14 cm) A direct cross-connection suggests the piping system may be subjected to ____? A. Backpressure or backsiphonage B. Backsiphonage only C. Periodic inspection D. Sustained pressure E. Toxic materials - ANSWER Backpressure or backsiphonage A double check valve assembly installed in a vertical flow down orientation is only allowed ______? A. In a basement or vault B. If the assembly was tested and approved as such C. If the check weight does not compress the spring D. On fire-suppression systems E. On water supply service connections - ANSWER If the assembly was tested and approved as such A double check valve assembly is installed 12 in. (30.5 cm) above the floor for _____? A. Electrical code compliance B. Floor draining C. Maintenance D. Mechanical code compliance E. Rodent control - ANSWER Maintenance A field test report for a double check valve assembly will include the manufacturer's name, model, size, and _____? A. Body material B. Date of manufacture C. Serial number D. Working pressure (maximum) E. Working temperature (maximum) - ANSWER Serial number A fire sprinkler system's backflow protection for a black-iron pipe system is typically ____? A. An air-gap separation B. A double check valve assembly C. A reduced pressure principle assembly D. A reduced pressure detector assembly E. No protection required - ANSWER A double check valve assembly .
Escuela, estudio y materia
- Institución
- Backflow Prevention
- Grado
- Backflow Prevention
Información del documento
- Subido en
- 23 de abril de 2024
- Número de páginas
- 33
- Escrito en
- 2023/2024
- Tipo
- Examen
- Contiene
- Preguntas y respuestas
Temas
-
backflow prevention practice exam 2024 questions
-
backflow prevention practice exam 2024
-
backflow prevention practice exam
-
backflow prevention questions and verified answers
-
backflow prevention exam qu
Documento también disponible en un lote