Fire Inspector 2 Questions with complete Solutions
1. What two physical properties of flammable liquids are used to classify them? - A. Flash Point B. Boiling point 2. The amount of heat given off by a particular substance during the combustion process is called? - Heat of Combustion 3. The minimum temperature at which a liquid gives off sufficient vapor to form an ignitable mixture at the surface but not sufficient to sustain combustion is called its___________ - Flash Point 4. Name the standard developed by the national Fire Protection Association to regulate the manufacture, storage, and handling of aerosol products._____________ - NFPA 30B 5. __________liquids may be dispensed by gravity from approved equipment? - Flammable 6. Special sprinkler requirements for flammable liquid storage facilities can be found in _________ - NFPA 30 7. A container is any vessel with a capacity equal to or less than_______ - 60 Gallons 8. Stationary tanks must be identified using the ________ hazard identification system. - High 9. Underground storage tanks (UTS) are tested with air at_____ PSI prior to being placed within the excavation - 3-5 PSI 10. The storage arrangement in which aerosol products are stored throughout the facility intermixed with other commodities is called _______ storage. - Nonsegregated Storage 11. Flammable liquids are? - A liquid having a flash point below 100 degrees, type IA IB and IC 12. Combustible liquids are? - A liquid having a flash point at or above 100 degrees 13. Water Miscible is also known as - Water soluble or will dissolve in water 14. What type of aerosol storage is enclosed by rated walls or chain linked fence enclosures and are protected by a sprinkler system? - Segregated Storage 15. A Structure designed and constructed in a building to be used for the application of flammable finishes, with power ventilation and a fixed fire suppression system. - Spray Booth 16. A Room designed and constructed for the application of flammable finishes complying with building codes. - Spray Room 17. An area designed and constructed to be used for the application of flammable finishes complying with building codes. - Spray Area 18. _____________ should never be air tested that contains any flammable or combustible liquids - Underground storage tanks 19. What are becoming a popular replacements for USTs for the storage of gas and Building fuel? - 6,000 gal Aboveground Storage tanks (AST) 20. The model fire prevention codes prohibit Dry Cleaners to do what without prior approval by Fire Official? - Change the solvents that they use to another. 21. Spray Booths, Spray Rooms, and Spray Areas are prohibited in what occupancies buildings? - A. Assemblies 22. E. Educational I. Institutional and 23. R. Residential 24. Why are auto body repair facilities strictly prohibited from spraying outside of spray booths? - Power sanding, grinding and other spark-producing tools provide a ready ignition source. 25. Deflagration occurs at what speed? - Subsonic Speeds 26. Detonation occurs at what speed? - Subsonic speed
Geschreven voor
- Instelling
- Tcfp instructor 2
- Vak
- Tcfp instructor 2
Documentinformatie
- Geüpload op
- 21 april 2024
- Aantal pagina's
- 7
- Geschreven in
- 2023/2024
- Type
- Tentamen (uitwerkingen)
- Bevat
- Vragen en antwoorden
Onderwerpen
-
fire inspector 2 questions with complete solution
Ook beschikbaar in voordeelbundel