100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

MD HVAC Masters 2024/2025 graded A+ by experts

Puntuación
-
Vendido
-
Páginas
8
Grado
A+
Subido en
19-04-2024
Escrito en
2023/2024

MD HVAC Masters 2024/2025 graded A+ by experts

Institución
HVAC Journeyman
Grado
HVAC Journeyman









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
HVAC Journeyman
Grado
HVAC Journeyman

Información del documento

Subido en
19 de abril de 2024
Número de páginas
8
Escrito en
2023/2024
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

  • hvac journeyman

Vista previa del contenido

MD HVAC Masters

For mechanical draft system, exit terminal located adjacent to public walkways shall be no less
than ____________ feet above finish ground level. - ANS7

A 2000 sq. ft. "Type II" dry-cleaning systems shall be provided with an exhaust no less than
__________ CFM's. - ANS2000

A bathroom in a dwelling unit must be provided with a minimum intermittent exhaust of
__________. - ANS50 CFM

A hot-water heating boiler that has a 5,000,000 BTU/HR input shall have a minimum clearance
of _____________ from the top of the boiler to the ceiling. - ANS3 feet

A heater installed in a public garage must be installed a minimum distance of ____________
above the floor? - ANS8 feet

______________ is a tube or pipe used to carry refrigerant gas from evaporator to the
compressor - ANSSuction line

Commercial appliance exhaust outlets that terminate above roof shall have the discharge
opening located not less than ___________ inches above the roof surface. - ANS40

A run winding in a compressor has _____________ resistance than the start winding. -
ANSLess

A duct that has an operating temperature of 150 deg F shall be insulated to limit the exposed
surface temperature to ___________. - ANS120 °F

Hydronic pipe system should be cleaned with water and _____________ after installation. -
ANSTrisodium Phosphate

Using a psychrometric chart in the Modern Refrigeration, what will the wet bulb be if the dry bulb
is 80 degrees and the humidity is 30%? - ANS60 °F

Outside air exhaust and intake openings shall be located a minimum of ____________ feet from
lot lines or building on the same lot. - ANS10

Down - pipe support material must not promote: - ANSGalvanic action

Central HVAC systems shall have air filters installed in which of the following locations? -
ANSUpstream from any exchanger coil

, An auxiliary drain pan used in secondary drain systems for an a/c systems shall have a
minimum depth of ________ inch. - ANS1 ½

A ventilation supply system shall deliver the required rate of supply air within an occupied space
minimum of ____________ above the floor. - ANS3"

In a unit controlled by a thermostat the differential is the difference between ____________. -
ANSTemperature at which the switch turns the burners on and the temperature at which the
switch turns the burners off

A ___________ is used to measure relative humidity by comparing wet/dry bulb temperatures. -
ANSSling Psychrometric

A (n) ___________ prevents slugging in a heat pump system. - ANSAccumulator

Any appliance in which the products of combustion at the point of entrance to the flue under
normal operating conditions have a temperature of 1000 degrees is a ____________ appliance.
- ANSLow

A connector to a chimney flue shall be at least __________ the lowest portion of the interior of
the flue. - ANS12" above

The temperature for a fire damper actuating device shall not be less than ___________
degrees. - ANS160

Horizontal pipes in a hydronic system should ____________. - ANSBe sloped toward boiler

A boiler shall have an unobstructed passageway of ___________ around all sides. - ANS18"

What is the color code for R-410A? - ANSRose

A one (1) ton refrigeration system has the equivalent of _________ BTU's. - ANS12,000

A safety belt lanyard shall be a minimum of ½" nylon, or equivalent, with a maximum length to
provide for a fall of no greater than __________ feet? - ANS6

The purpose of a suction accumulator is _______________. - ANSIt catches and holds liquid
refrigerant that has passed through the evaporator coil so it will not enter the compressor

Minimum size access opening for equipment installed in an underfloor area is ____________. -
ANS22 x 30

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Ascore Chamberlain College Nursing
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
111
Miembro desde
1 año
Número de seguidores
13
Documentos
2202
Última venta
1 semana hace

Welcome to Ascore ! The place to find the best study materials for various subjects. You can be assured that you will receive only the best which will help you to ace your exams. All the materials posted are A+ Graded. Please rate and write a review after using my materials. Your reviews will motivate me to add more materials. Thank you very much!

4.0

22 reseñas

5
12
4
3
3
4
2
2
1
1

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes