Fire Inspector 2: Combined
Fire Inspector 2: Combined Fire protection engineers have established _____ PSI as a minimum required residual pressure when computing the available water for flow test results. - 20psi The most common gallonage rating for horizontal shaft pumps in use today are _____ - _____ GPM. - 500 - 1500 gpm A fire pump serving a standpipe system should be tested ______ - weekly A fire department pumper can effectively supply around ______ feet in a high rise building depending on hydrant pressure and other factors. - 450 feet Class 2 standpipe is for __________ use - occupational Standpipe classifications: 1. 2 3. - 1. Fire Dept only 2. Occupant use only 3. Both Fire Dept and Occupant use NFPA 13D requires _______ for any sprinkler - 18 GPM Minimum water supply for a class 1 or 3 standpipe system is _____ gpm for at least 30mn with 65psi residual pressure at the highest outlet. - 500 Stored material should not be stacked closer than ____ inches to a sprinkler head - 18 inches _______ system is used when it is especially important that water damage be prevented, even if the sprinkler pipes should break accidentally. - Preaction Fire dampers are usually activated by _____ ______ - fusible links ________ detectors are - activated by heat (expansion) and are self-resetting (automatic) - Bimetallic Class ____ fires: fire of flammable and combustible liquids and gases such as gasoline, kerosene and propane - B Pressure tanks should be filled ______ of water with ____ psi - 2/3; 75psi Fire extinguishers 40lbs should be mounted no higher than ______ feet from the floor - 3 1⁄2 _______ _______ is an aqueous solution of either potassium carbonate and water or potassium acetate and water - Wet chemical _______ _______ extinguishers limitations are the clean-up - Dry chemical _____ ______ agents are difficult to clean up due to water repellant - Dry chemical When liquid propane gas is stored in the same area as flammable or combustible liquid, the containers must be at least ______ feet apart - 20 feet Freeboard should never be more than ___ inches - 6 _________ ________ is wood chips glued together to make flat sheets - Particle board The maximum size for an approved safety can is ___ gallons - 5 Open burning fire should not be allowed within ______ feet of a structure - 50 Approved incinerators for burning trash should be at least _____ feet from a structure - 15 Fire in an approved burn container should not be within ____ feet of a structure - 25 Explosives are class ___ hazardous
Información del documento
- Subido en
- 11 de abril de 2024
- Número de páginas
- 34
- Escrito en
- 2023/2024
- Tipo
- Examen
- Contiene
- Preguntas y respuestas