Fire Inspector 2 Test Questions
Fire Inspector 2 Test Questions What two physical properties of flammable liquids are used to classify them? - A. Flash Point B. Boiling point The amount of heat given off by a particular substance during the combustion process is called? - Heat of Combustion The minimum temperature at which a liquid gives off sufficient vapor to form an ignitable mixture at the surface but not sufficient to sustain combustion is called its___________ - Flash Point Name the standard developed by the national Fire Protection Association to regulate the manufacture, storage, and handling of aerosol products._____________ - NFPA 30B __________liquids may be dispensed by gravity from approved equipment? - Flammable Special sprinkler requirements for flammable liquid storage facilities can be found in _________ - NFPA 30 A container is any vessel with a capacity equal to or less than_______ - 60 Gallons Stationary tanks must be identified using the ________ hazard identification system. - High Underground storage tanks (UTS) are tested with air at_____ PSI prior to being placed within the excavation - 3-5 PSI The storage arrangement in which aerosol products are stored throughout the facility intermixed with other commodities is called _______ storage. - Nonsegregated Storage Flammable liquids are? - A liquid having a flash point below 100 degrees, type IA IB and IC Combustible liquids are? - A liquid having a flash point at or above 100 degrees Water Miscible is also known as - Water soluble or will dissolve in water What type of aerosol storage is enclosed by rated walls or chain linked fence enclosures and are protected by a sprinkler system? - Segregated Storage A Structure designed and constructed in a building to be used for the application of flammable finishes, with power ventilation and a fixed fire suppression system. - Spray Booth A Room designed and constructed for the application of flammable finishes complying with building codes. - Spray Room An area designed and constructed to be used for the application of flammable finishes complying with building codes. - Spray Area _____________ should never be air tested that contains any flammable or combustible liquids - Underground storage tanks What are becoming a popular replacements for USTs for the storage of gas and Building fuel? - 6,000 gal Aboveground Storage tanks (AST) The model fire prevention codes prohibit Dry Cleaners to do what without prior approval by Fire Official? - Change the solvents that they use to another. Spray Booths, Spray Rooms, and Spray Areas are prohibited in what occupancies buildings? - A. Assemblies E. Educational I. Institutional and R. Residential
Información del documento
- Subido en
- 11 de abril de 2024
- Número de páginas
- 9
- Escrito en
- 2023/2024
- Tipo
- Examen
- Contiene
- Preguntas y respuestas