Ovation Certification the OV400 Processor Line
Ovation Certification the OV400 Processor Line What are Possible Quality Reasons? - Latched Quality Tagged Out Hardware Error Oscillating Point Sensor Calibrate Scan Removed Data Link Failure Substituted Entered Value Algorithm Application Test Mode User Definable Engineering Limit Reasonability Limit What are the types of Quality and what is displayed for each next to the point? - Good = none Fair = F Poor = P Bad = B Timed Out = T (not formally defined as a Quality type) For what reasons will a point display Fair Quality? - An Operator entered value. The result of a quality checking algorithm in the application (loop propagation). For what reasons will a point display Poor Quality? - Generated from certain algorithms if some inputs were bad and some were good. For what reasons will a point display Bad Quality? - Faulty input hardware. Input out of specified sensor range (analog). The removal of a point from scan. The result of a quality checking algorithm (loop propagation). Why would a point indicate Timed Out? - The point is not being updated. The drop that broadcasts the point is probably off the network. Define the AMS Suite - AMSTM Suite (Asset Management System), is a comprehensive and integrated family of applications from Emerson developed for: - predictive maintenance - performance monitoring - and economic optimization. What applications are provided with the AMS Suite? - Asset Portal Intelligent Device Manager Machinery Health Manager Equipment Performance Monitor What is the purpose of the Asset Portal? - Decision support, reporting and analysis on the health and performance of your production assets. What is the purpose of the Intelligent Device Manager? - Predictive and proactive maintenance of instruments and valves. What is the purpose of the Machinery Health Manager? - Predictive and proactive maintenance of mechanical equipment. What is the purpose of the Equipment Performance Monitor? - Predictive and proactive maintenance of process and mechanical equipment. For which type of devices does AMS work with? - - HART field devices - Foundation field bus devices List the types of Analog Input Modules. - Analog Input (13 bits) Analog Input (14 bits) Analog High Speed Input (14 bits) HART Analog Input HART High Performance Analog Input RTD 4-Input RTD 8-Input
Información del documento
- Subido en
- 21 de marzo de 2024
- Número de páginas
- 8
- Escrito en
- 2023/2024
- Tipo
- Examen
- Contiene
- Preguntas y respuestas