California ICC Service Technician with complete questions and answers rated A. Latest Version updated 202425
California ICC Service Technician with complete questions and answers rated A. Latest Version updated 202425 (T/F) Gasoline vapors are lighter than air False: Gas vapors are 3-4 times HEAVIER than air Overfill Protection notifies the operator when tank is at what level capacity? If equipped it will notify audibly and visually when the tank reaches 90% Capacity. Cathodic protection systems must be inspected by a certified cathodic protection tester within______ months of installation 6 months Annual Monitor Certification records must be maintained on site for a period of________ years 3 years The minimum monetary punishment for any person who falsifies monitor records is? $5,000 The quickest route for exposure to toxic substance is? Inhalation For temporary tank closure you still need to monitor the tank but you don't need an engineering report. Is this a true statement? Yes Asphyxiation is most likely to occur in low lying areas where heavier-than-air-air-vapors accumulate. Asphyxiation can be caused by: An Oxygen depleted environment Where are ATG probes installed? Through an opening in the top of the tank. What is the minimum fine for disabling a monitoring system? $5,000 (T/F) when performing secondary containment testing the spill buckets get tested as well. False: Spill buckets get tested during the annual monitor certification. Who must the annual monitor certification test results be sent to and when must they be notified prior to testing and after testing? Local agency must be notified prior 48 hours prior and results must be submitted within 30 days of testing (T/F) Stage II vapor recovery is a system for exchanging gasoline vapors in a vehicle fuel tank and product in a storage tank so that vapor omissions to the environment during refueling are greatly reduced. True: because Stage I vapor recovery is from fuel delivery truck to storage tank __________must report an un-authorized release within _________ hours to the local agency The owner or operator 24 hours If automatic line leak detectors fail testing, what must happen? They must be replaced and be able to detect a release of 3 gallons per hour at 10 pounds per square inch. (T/F): The area inside the tank covered by fuel is considered the "Ullage" False: The area inside the tank not covered by fuel is considered the "Ullage" If equipped with an ATG it shall be programmed to test the tank________ At least monthly (T/F) Spill buckets must provide drainage for spilled product into secondary containment sump? False: spilled product is released back into the tank by the drain valve, not into the secondary containment (Fill Sump) Another name for the local agency CUPA - Certified unified program agencies Who implements the new bio-fuel regulations? (CUPA) The Local Agency The Automatic tank gauge ATG shall test the tank at least once per month at the following leak rate________? 0.2 gph (T/F) Rapid breathing, increased heartbeat, poor attention, poor coordination, and rapid fatigue can be affects of and oxygen rich environment. False: these are all signs of an oxygen depleted environment. If steel flex lines are not in a sump do they need to be protected against contact with backfill material and water? Title 23 section 2636 (b) All corrodible underground piping, if in direct contact with backfill material, shall be protected against corrosion. Fiberglass reinforced plastic, steel with cathodic protection, or steel isolated from direct contact is OK. A __________ is used when there is not enough slope on the vapor return lines from the dispensers to the tanks. A liquid collection point, vapor pot, or vapor belly pot. (T/F) an automatic tank gauge can fulfill the leak detection requirement in California for what type of tank? Single wall tanks (T/F) between gasoline, jet fuel, kerosene, and diesel. Gasoline is the most hazardous petroleum product. True As of December 31, 2003 all UST's shall be retrofitted with __________ Under Dispenser Containment (UDC) For bio-fuels, where are the sites compatibility forms sent to? The Local Agency (CUPA) In a suction system where should the check valve be located? Above grade and as close to the pumping unit as possible (T/F) During an annual monitor certification, a site map is required of all UST components and the location of the monitoring system. True (T/F) spell buckets require a drain valve, a minimum capacity of 5 gallons, in the metal exterior wall shall be protected from galvanic corrosion. True (T/F) grounding is a bond between two or more electrically conductive objects in the earth? True: all objects are at zero electrical potential Secondary containment systems installed after 1/1/2001 shall be tested upon installation,__________ months after installation and every________month thereafter. 6 , 24 What is the maximum prison term for anyone convicted of intentionally disabling or tampering with an automatic leak detection system? 1 year (T/F) Product piping test foods left in place must have the pop it removed from the Schrader valve in the Schrader valve must be left facing down. True (T/F) Single wall tanks have interstitial sensors. False: only double wall Containments have interstitial spaces usually containing the annular space sensors. (T/F) The monitor certification stickers shall have the contractors phone number, your name, the contractors license number, and the date the USD component was certified. False: it is only required for the contractors license number and the date the UST component was certified
Escuela, estudio y materia
- Institución
- California ICC
- Grado
- California ICC
Información del documento
- Subido en
- 13 de marzo de 2024
- Número de páginas
- 5
- Escrito en
- 2023/2024
- Tipo
- Examen
- Contiene
- Preguntas y respuestas
Temas
-
california icc service technician with complete q
Documento también disponible en un lote