Api 653 Formulas All Answers Correct
API 653 FORMULAS ALL ANSWERS CORRECT 1.5-4.0 mils Linings- Typically anchor profile of steel surface required for the installation of a tank bottom lining 652: 7.5 Welds- Maximum undercut of a vertical weld & nozzle weld 650: 8.5.2.b Welds- Maximum undercut of a horizontal weld 650: 8.5.2.b 1/32" Welds- Maximum diameter of a surface porosity cluster 650: 8.5.2.c 1/64" 3/32" Weld Qualification- Max allowed discontinuity in a bend test IX: QW-163 1/8" Nameplates- Minimum size of name plate letters 650: 10.1.1 & 653: 13.1.1.1 5/32" Bottoms- Minimum external projection of bottom plate on an existing tank (from toe of shell-to bottom FW) 653: 4.4.5.7 3/8" Reconstruction- Max amount of peaking allowed in vertical welds 653: 10.5.4 1/2" Shell Calcs- When calculating tmin for shell LTA, minimum distance away from a weld where "E" is always 1.0 653: 4.3.3.1 (definitions) 1" or 2t 1" Shell Patch- Minimum overlap of shell lap-patch used to cover a hole (edge of hole to edge of patch) 653: 9.3.2.3 NDE- When performing a PT examination, minimum distance to clean beyond the area to be examined V: T-642.b 1" NDE- When performing a MT examination, minimum distance to clean beyond the area to be examined V: T-741.1.b 1" Reconstruction- Maximum amount of banding allowed in a horizontal weld 653: 10.5.5 1" Bottoms- Minimum overlap required for single-welded lap joints 650: 5.1.3.5 Bottoms- Minimum external projection of bottom plate on a new tank 650: 5.4.2 1" 2" Vacuum Box- Minimum overlap of previously test surfaces when using a vacuum box 650: 8.6.5 2" 2" Bottom Patch- Minimum overlap of bottom lap-patch fillet weld to the nearest existing bottom weld 653: Fig. 9.13 2" Bottom Patch- Minimum distance bottom lap-patch fillet weld to the nearest existing bottom weld 653: Fig. 9.13 Shell Patch- Minimum radius of a shell lap-patch 653: 9.3.1.4 2" Reconstruction- If reusing bottom plates, minimum distance to cut from existing bottom welds (if plates are not deseamed) 653: 10.3.2.1 2" Reconstruction- If reusing roof plates, minimum distance to cut from existing roof welds (if plates are not deseamed) 653: 10.3.4.1 2" Shell Pitting- Maximum allowed vertical length of pits on a tank shell 653: 4.3.2.2.b 2" in 8" line Bottom Pitting- Maximum allowed length of pits in the critical zone that can be repaired by weld buildup 653: 9.10.1.6.a 2" in 8" arc Bottoms- Radial length of critical zone measured from shell 653: 3.10 Bottoms- Suggested sand pad thickness 650: B.3.2 3-4" 3" Welds- Minimum distance between clusters of surface porosity 650: 8.5.2.c 4" Shell Patch- Minimum dimension of a shell lap-patch 653: 9.3.1.7 4" Shell Patch- Minimum radius of a shell flush-patch 653: Fig. 9.1 "R" dimension 6" Shell Calcs- When calculating tmin for shell LTA, minimum distance away from the rivet where "E" is always 1.0 653: 4.3.4.1 6" Bottom Patch- Minimum size of bottom lap-patch that does NOT cross a bottom seam 653: 9.10.1.1.b 6" Bottom Patch- Minimum distance between a bottom lap-patch and the shell for patches that do NOT extend to the shell 653: Fig. 9.13 or 9.10.1.2.b 6" Reconstruction- If reusing shell plates, minimum distance to cut from existing shell welds (if plates are not deseamed) 653: 10.3.3.1.c 6" RT- Minimum diagnostic length of a RT for vertical or horizontal welds 650: 8.1.2.8 653: 12.2.1.7 6" Weld Qualify- Minimum weld length when qualifying a welder with RT/UT using a coupon or 1st production weld IX: QW-302.2 IX: QW-304.1 6" 6" Weld Qualify-Minimum weld length when qualifying a welding operator with RT/UT of a test coupon IX: QW-302.2 Shell Patch- Minimum distance a lap patch shall overlap a shell weld 653: 9.3.1.5 Corrosion- Area to dig when checking for soil-to-air corrosion 575: 8.2.10 NDE- Distance of eye-to-part to count as visual exam 577: 9.3.1.e Vacuum Box- Typical size of a vacuum box 650: 8.6.1 6" 6-12" 6"-24" 6" x 30" Shell Patch- Minimum dimension of a shell flush-patch 653: 9.2.2.1 12" Bottoms- Minimum dimension that a 3-lap joint can be from: other 3-laps, the shell, or annular plate joints 650: 5.1.5.4.2 12" Bottom Patch- Minimum dimension of bottom lap-patch that crosses a bottom seam 653: 9.10.1.1.a 12" Foundations- Suggested height above grade for new tank bottoms 650: B.3.1 12" Shell Patch- When adding a shell flush-patch that extends to a horizontal shell weld, minimum distance to cut the horizontal weld past the new vertical welds 653: Fig. 9.1 note 2 12" 12" Shell Patch- Dimension of a shell flush-patch that is considered either a major repair or alteration 653: 3.20.c Definition- Dimension of a shell vertical weld if repaired or replaced is considered a major repair of major alteration 653: 3.20.e 12" Bottom Patch- Maximum width of bottom patch in the critical zone 653: Fig. 9.13 note 3 24" Bottoms- Minimum radial width of annular plate (distance between shell and nearest bottom fillet weld) 650: 5.1.5.4.3 & 5.5.2 24" NDE- Maximum distance of eye-to-part to count as visual exam 575: 9.2.1 24" Hot Tap- Minimum height of liquid above new nozzle during the hot tap operation 653: 9.14.1.2 36" Weld Qualify- minimum weld length when qualifying a welding operator with RT/UT of first production weld IX: QW-305.1 36"
Información del documento
- Subido en
- 12 de marzo de 2024
- Número de páginas
- 20
- Escrito en
- 2023/2024
- Tipo
- Examen
- Contiene
- Preguntas y respuestas