Nfpa 99 Practice Exam Test
Nfpa 99 Practice Exam Test The ASSE 6040 Standard applies to individuals who _______________ medical gas and vacuum systems. A install B perform inspections of new installations C maintain D verify - CORRECT ANSWER-maintain At sea level the atmospheric pressure is 14.7 psia. What is the absolute pressure of a 50 psig (gauge pressure) system at sea level? A 64.7 psia B 50 psia C 34.7 psia D 60 psia - CORRECT ANSWER-64.7 psia Medical Gas _______________________________ shall be able to describe how to find and implement manufacturer specific maintenance requirements for the medical gas and vacuum system components per ASSE 6000 Annex D and CGA E.10. A Supplier or Distributor B Maintenance Personnel C Authority having jurisdiction D Verifier or Inspector - CORRECT ANSWER-Maintenance Personnel Medical Gas Maintenance Personnel shall be able to identify and describe the hazards resulting from improper maintenance of medical gas and vacuum systems, including: A Flow B Cross Connections C Contaminants D All of the above - CORRECT ANSWER-All of the above ASSE 6000 daily checks of bulk liquid systems include all of the following with the exception of ______________. A Primary and Reserve (if equipped) Tank Contents B Pressure Dew Point Temperature C Leaks or Unusual Icing D Proper pressure maintained - CORRECT ANSWER-Pressure Dew Point Temperature Per ASSE 6000 Annex D typical maintenance procedures include _______________ checks of the Medical Air Moisture removal system (after cooler, dryer drain, receiver drain, sight glass, etc.). A Daily B Weekly C Monthly D Annually - CORRECT ANSWER-Daily Per ASSE 6000 Annex D the Medical Air __________ is typically checked daily. A Dew Point Monitor B Carbon Monoxide Monitor C Filter Condition D Both A & B E All of the above - CORRECT ANSWER-Both A & B Typical monthly checks, per ASSE 6000 Annex D, of area alarms include all of the following except : A Audible Signal B Visual Signals C Emergency Instructions D Gauge Pressure Read Outs - CORRECT ANSWER-Emergency Instructions Per ASSE 6000 Annex D, the medical air compressor intake location and filter condition should be checked _______________. A Daily B Weekly C Quarterly D Annually - CORRECT ANSWER-Quarterly Minimum Maintenance Schedule, per ASSE 6000 Annex D, should include annual checking of ________________ for Flow, Pressure/Vacuum, Damage, and Wear. A All outlets & inlets B All critical care outlets & inlets C 50% of all critical care outlets D Annual testing of outlets & inlets is not recommended - CORRECT ANSWER-All critical care outlets & inlets Per ASSE 6000 Annex D the medical air compressor _____________________ should be calibrated annually. A Dew Point & Carbon Monoxide Monitors B Carbon Monoxide Monitor Only C Gauges D Motor Overloads - CORRECT ANSWER-Dew Point & Carbon Monoxide Monitors Per ASSE 6000 Annex D & CGA E.10, after reassembly of equipment is shall be tested prior to being returned to service for ______________________________. A Gas Flow B Pressure C Cross Connection
Escuela, estudio y materia
- Institución
- Nfpa
- Grado
- Nfpa
Información del documento
- Subido en
- 8 de marzo de 2024
- Número de páginas
- 16
- Escrito en
- 2023/2024
- Tipo
- Examen
- Contiene
- Preguntas y respuestas
Temas
-
nfpa 99 practice exam test
-
the asse 6040 standard applies to individuals who
-
at sea level the atmospheric pressure is 147 psia
-
the electrical power and controls for each pump mo
Documento también disponible en un lote