ACI Concrete Field Testing Technician - Grade 1 (18) Exam With Complete Solutions
ACI Concrete Field Testing Technician - Grade 1 (18) Exam With Complete Solutions ASTM C1064 - answerStandard Test Method For Temperature of Freshly Mixed Hydraulic- Cement Concrete The end of the temperature sensing portion of the temperature measuring device shall be submerged a minimum of ____ into the freshly mixed concrete. - answer3 inches [75 mm] C1064, Sec. 8.1 The temperature measuring device shall have a capacity of measuring the temperature of freshly mixed concrete to ± ____ °F (± ____ °C) throughout a range of ____ °F ( ____ °C). - answer±1 °F (±0.5 °C) ; 30 to 120 °F (0 to 50 °C) C1064, Sec. 5.2 The temperature measuring device shall be calibrated ____ , or whenever there is a question of ____ . - answerannually, accuracy C1064, Sec. 6.1 The temperature of concrete may be measured in a wheelbarrow. True or False - answerTrue The temperature of concrete may be measured in a wall form. True or False - answerTrue C1064, Sec. 7.1 A composite sample of concrete is required even if the only purpose for obtaining the sample is to determine temperature. True or False - answerFalse C1064, Sec. 7.2.2 What must be done to the sample container prior to sampling the concrete? - answerDampen with water C1064, Sec. 7.2.1 What must be done to the concrete surrounding the temperature measuring device after the device is submerged in the fresh concrete? - answerClose off air voids by gently pressing the concrete around the device C1064, Sec. 8.1 How long must the temperature measuring device remain in the freshly mixed concrete? - answerminimum of two minutes, maximum of five minutes C1064, Sec. 8.2 After the temperature of the concrete is read, what is then required? - answerReporting of temperature C1064, Sec. 9.1 The temperature of the concrete is reported to the nearest ____ °F - answer1 °F (0.5 °C) C1064, Sec. 9.1 According to Test Method C1064, what is one reason to take the temperature of concrete? - answerVerify conformance to a specified requirement for temperature of concrete C1064, Sec. 4.1 A maximum temperature of freshly mixed concrete is specified in ASTM C1064. True or False - answerFalse The sample of concrete used for temperature determination must be rodded 25 times. True or False - answerFalse C1064, Sec. 7 & 8 ASTM C172 - answerStandard Practice for Sampling Freshly Mixed Concrete Sampling by this practice covers procedures for obtaining representative samples, on which tests are to be performed to determine ____ with quality requirements of the specifications under which the concrete is furnished. - answercomplianc
Escuela, estudio y materia
- Institución
- ACI Concrete
- Grado
- ACI Concrete
Información del documento
- Subido en
- 23 de febrero de 2024
- Número de páginas
- 25
- Escrito en
- 2023/2024
- Tipo
- Examen
- Contiene
- Preguntas y respuestas
Temas
-
aci concrete field testing technician grade 1 1
Documento también disponible en un lote