Kettering TMC Modules exam 2024 with 100% correct answers
A balloon-tipped, flow-directed catheter is positioned in the pulmonary artery with the balloon deflated. Which of the following pressures will be measured by the proximal lumen? A) CVP B) PAP C) PWP D) MAP A. CVP Swans gans catheter for hemodynamic monitoring. Distal deflated is PAP, Distal inflated is PWP All of the following could cause a capnography reading to change from 36 torr to 30 torr EXCEPT A) endotracheal tube positioned in the right mainstem bronchus B) hyperventilation C) pulmonary emboli D) hypovolemia A. endotracheal tube positioned in the right mainstem bronchus. This will cause PeTCO to increase