in a large main magnetic field such as those employed in MRI, the motion of a hydrogen proton has been described as wobbling like a spinning top. this motion is called A) precession B) resonance C) frequency D) angular momentum - ANSWER-precession magnetic resonance imaging is derived from the process known as: A) magnetic resonance angiography B) magnetic relaxation imaging C) nuclear magnetic resonance D) nuclear resonance imaging - ANSWER-nuclear magnetic resonance Once the nmv has moved away from equilibrium, the following will occur A) the longitudinal component will increase B) the transverse component will decrease C) the longitudinal component will stay the same D) the transverse component will increase - ANSWER-the transverse component will increase In MR, substances respond to a specific radio frequency which is known as: A) magnetic frequency B) radio frequency C) gyro-magnetic frequency D) resonance frequency - ANSWER-resonance frequency the introduction of gadolinium based contrast enhancement agents by intra-venous injection can involve passing through an abnormal blood brain barrier. the tissue compartments involved are the: A) intravascular to interstitial B) extracellular to intracellular

Mostrar más Leer menos
Institución
ARMRIT
Grado
ARMRIT











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
ARMRIT
Grado
ARMRIT

Información del documento

Subido en
7 de enero de 2024
Número de páginas
36
Escrito en
2023/2024
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

ARMRIT EXAM QUESTIONS &
ANSWERS 100% CORRECT

Different tissues that have signals that appear similar on an MR image are described
as:
A) hypointense
B) hyperintense
C) isointense
D) isodense - ANSWER-isointense

in a large main magnetic field such as those employed in MRI, the motion of a hydrogen
proton has been described as wobbling like a spinning top. this motion is called
A) precession
B) resonance
C) frequency
D) angular momentum - ANSWER-precession

magnetic resonance imaging is derived from the process known as:
A) magnetic resonance angiography
B) magnetic relaxation imaging
C) nuclear magnetic resonance
D) nuclear resonance imaging - ANSWER-nuclear magnetic resonance

Once the nmv has moved away from equilibrium, the following will occur
A) the longitudinal component will increase
B) the transverse component will decrease
C) the longitudinal component will stay the same
D) the transverse component will increase - ANSWER-the transverse component will
increase

In MR, substances respond to a specific radio frequency which is known as:
A) magnetic frequency
B) radio frequency
C) gyro-magnetic frequency
D) resonance frequency - ANSWER-resonance frequency

the introduction of gadolinium based contrast enhancement agents by intra-venous
injection can involve passing through an abnormal blood brain barrier. the tissue
compartments involved are the:
A) intravascular to interstitial
B) extracellular to intracellular

,C) hepatobiliary to renal
D) extradural to renal - ANSWER-intravascular to interstitial

t2 is the measurement of time fot the transverse component of the NMV to decrease
what percentage of its maximum value after the application of a 90 degree radio-
frequency pulse
A) 33%
B) 63%
C) 37%
D) 67% - ANSWER-37%

in the USA, the MRI system's magnetic field and vector that represents it is symbolized:
A) B1
B) B2
C) B3
D) B0 - ANSWER-B0

The resonance frequency of any substance in a magnetic field can be calculated by
employing the
A) damadian equation
B) larmor equation
C) faraday equation
D) lauterbur equation - ANSWER-Larmor equation

in a pulse sequence, transmitting an initial 90 degree radio-frequency pulse will cause
the NMV to:
A) remain at equilibrium
B) shift in both size and direction
C) move to antiparallel
D) rephase - ANSWER-shift in both size and direction

Which type of electromagnetic coils are designed to stimulate and detect an MR signal?
A) gradient coils
B) radio-frequency coils
C) shim coils - ANSWER-radio-frequency

tissues that are less efficient at spin-spin interactions because they contain more free
water, such as CSF, should have
A) High T2 values and produce hypointense signals
B) HIgh T2 values and produce hyperintense signals
C) low T2 values and produce hypointnese signals
D) low T2 values and produce hyperintense signal - ANSWER-High T2 values and
produce hyperintense signals

magnetism can be defined as the ability of certain substances to attract:
A) Copper, aluminum, tin

,B) Iron, cobalt, nickel
C) Bronze, niobium, titanium
D) Neodymium, niobium-titanium, lodestone - ANSWER-Iron, cobalt, nickel

the purpose of magnetic resonance angiography is to image the:
A) stationary soft tissue
B) blood flow
C) vessel lumen
D) only abnormal vessels - ANSWER-blood flow

the strength of very large magnetic fields like those employed in MRI systems, the SI
unit most commonly used is:
A) Tesla
B) Gauss
C) Kilogauss
D) militesla - ANSWER-Tesla

the larmor frequency of hydrogen protons in a 1.5 tesla magnetic field is:
A) 6.4 MHZ/Tesla
B) 12.8 MHz/Tesla
C) 25.5 MHz/tesla
D) 63.9 MHz/tesla - ANSWER-63.9 MHz/Tesla

In MR imaging, for chemical substance to be affected by the main magnetic field and
the radio-wave it must contain an:
A) Odd number of electrons
B) Odd number of total protons and neutrons
C) Even number of total electrons and neutrons
D) even number of protons - ANSWER-Odd number of total protons and neutrons

A 1.5T magnetic field is equal to:
A) 150 gauss
B) 1500 gauss
C) 15,000 gauss
D) 150,000 gauss - ANSWER-15,000 gauss

the components of the gyromagnetic ratio are:
A) stimulation to relaxation
B) protons to electrons
C) magnetic moment to angular momentum
D) main magnetic field to radio-frequency signal - ANSWER-magnetic moment to
angular momentum

fast transition phenomenon and entry phenomenon are theories that explain which of
the following characterisitics:
A) T1 effects

, B) T2 effects
C) hydrogen concentration
D) veolcity effects - ANSWER-Velocity effects

the effects of main magnetic field inhomogeneities on the FID signal are corrected for in
the spin echo sequence by applying a second radio frequency pulse. the flip angle of
this radio frequency pulse is:
A) 45 degrees
B) 60 degrees
C) 90 degrees
D) 180 degrees - ANSWER-180 degrees

of the following statements, which describes part of the basic MR imaging process:
A) a patient is placed isocenter to ionizing radiation
B) the patient is exposed to ionizing radiation
C) the generated image contains hypersense and hypodense areas
D) radio frequency signals interact with hydrogen protons - ANSWER-radio frequency
signals interact with hydrogen protons

which type of electromagnetic coils correct inhomogeneities in the main magnetic field?
A) gradient coils
B) radio frequency coils
C) shim coils - ANSWER-shim coils

immediately after an initial 90 degree radio frequency pulse is turned off, the hydrogen
protons will begin to:
A) Rephase
B) Dephase
C) Stay in the transverse plane
D) Stay in phase - ANSWER-Dephase

tissues that are very efficient at spin-lattice interactions near the larmor frequency, such
as fatty tissues should have:
A) Low T1 values and produce hyperintense signals
B) High T1 values and produce hyperintense signals
C) High T1 values and produce hypointense signals
D) Low T1 values and produce hypointense signals - ANSWER-Low T1 values and
produce hyperintense signals

T1 is the measurement of time for the longitudinal component of the NMV to recover
what percentage of its original value after the application of a 90 degree radio frequency
pulse?
A) 33%
B) 63%
C) 37%
D) 67% - ANSWER-63%

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
IMORA West Virginia University
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
194
Miembro desde
2 año
Número de seguidores
77
Documentos
5079
Última venta
6 horas hace

4.4

69 reseñas

5
49
4
8
3
8
2
1
1
3

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes