S12 sprinkler test
S12 sprinkler test with correct answers well elaborated 100% success. fire department connection - correct lly on exterior of building... FDNY can pump supplemental water into the sprinkler system, standpipe, or other system furnishing water for fire extinguishment to supplement existing water supplies. system control valve - correct controlling flow to water-based fire protection systems. fire command center - correct answers.... MFSPC - correct answers.... MLP - correct answers.... tags - correct closed section valves serving affected areas: area affected, brief description, occupancy classification, c of f number, estimated time until operational Green tag - correct impairment found in entire system- main control valve white tag - correct out of service- place on all fire department connecitons red tag - correct on main control valve if FULLY OR PARTIALLY out of service... put sprinkler company name, date of removal from service and anticipated time to operational blue disk - correct ally out of service- on all fire department connections water storage tank - correct answers.... OS & Y valve - correct ating type of control valve used for fire sprinkler system deluge valve - correct supply control valve intended to be operated by actuation of an automatic detection system that is installed in the same area as the discharge devices. INTENDED USE IS MANUAL AND AUTO deluge sprinkler system - correct ying open sprinklers that are attached to a piping system that is connected to a water supply through a valve that is opened by the operation of a detection system installed in the same areas as the sprinklers. WHEN IT OPENS, water flows into the piping system and discharges from all sprinklers attached. Early suppresion fast response sprinklers - correct response sprinkler that is listed for its capability to provide fire suppression of specific high challenge fire hazards extra large orifice sprinklers - correct answers.= or 1 inch less pressure to achieve a given discharge density extended coverage sprinkler - correct answers.400 max square feet discharge fire pump - correct answers.a provider of liquid flow and pressure dedicated to fire protection. A fire pump is a part of a fire sprinklers system water supply and can be powered by electric, diesel or steam. connected to public water source or tank. provides higher pressure to sprinkler system Glass bulb sprinkler - correct ted by heat breaking a glass bulb filled with a non freezing liquid with diameters that vary form 3 mm for quick response to 5 mm for standard response hose valve - correct to additional hose connection hydraulic placard - correct attached to a hydraulically calculated sprinkler system indicating the design density, required gallons per minute and pressure for the system to operate properly hydraulically calculated systems - correct d of sizing auto sprinkler piping using a prescribed amount of water to be distributed over a specific area. impairment coordinator - correct charge of safety during out of service systems intermediate level sprinkler - correct kler equipped with integral shields to protect the operating elemtn form discharge from sprinklers installed at higher elevations large orifice sprinkler - correct kler head with orifice size equal or greater than 3/4 and less than 1 inch
Escuela, estudio y materia
- Institución
- S12 sprinkler .
- Grado
- S12 sprinkler .
Información del documento
- Subido en
- 28 de diciembre de 2023
- Número de páginas
- 8
- Escrito en
- 2023/2024
- Tipo
- Examen
- Contiene
- Preguntas y respuestas