Garantie de satisfaction à 100% Disponible immédiatement après paiement En ligne et en PDF Tu n'es attaché à rien 4.2 TrustPilot
logo-home
Examen

NERC Standards with Complete Solution Rated A+

Note
-
Vendu
-
Pages
17
Grade
A+
Publié le
11-10-2023
Écrit en
2023/2024

NERC Standards with Complete Solution Rated A+ How Many Active Standards are in BAL (Resource and Demand Balancing) - Answer There are 8 Active Standards Listed Below: BAL-001-2 Real Power Balancing Control Performance Related Information Subject to Enforcement BAL-001-TRE-1 Primary Frequency Response in the ERCOT Region Related Information Subject to Enforcement BAL-002-3 Disturbance Control Standard - Contingency Reserve for Recovery from a Balancing Contingency Event Subject to Enforcement BAL-002-WECC-2a Contingency Reserve Related Information Subject to Enforcement BAL-003-1.1 Frequency Response and Frequency Bias Setting Related Information Subject to Enforcement BAL-004-WECC-3 Automatic Time Error Correction R elated Information Subject to Enforcement BAL-005-1 Balancing Authority Control Related Information Subject to Enforcement BAL-502-RF-03 Planning Resource Adequacy Analysis, Assessment and Documentation Related Information Subject to Enforcement BAL-001-2: Real Power Balancing Control Performance - Answer To control Interconnection frequency within defined limits. (2 Requirements) BAL-001-2: Real Power Balancing Control Performance R1 - Answer R1. The Responsible Entity shall operate such that the Control Performance Standard 1 (CPS1), calculated in accordance with Attachment 1, is greater than or equal to 100 percent for the applicable Interconnection in which it operates for each preceding 12 consecutive calendar month period, evaluated monthly. [Violation Risk Factor: Medium] [Time Horizon: Real-time Operations] BAL-001-2: Real Power Balancing Control Performance R2 - Answer R2. Each Balancing Authority shall operate such that its clock-minute average of Reporting ACE does not exceed its clock-minute Balancing Authority ACE Limit (BAAL) for more than 30 consecutive clock-minutes, calculated in accordance with Attachment 2, for the applicable Interconnection in which the Balancing Authority operates.[Violation Risk Factor: Medium] [Time Horizon: Real-time Operations] BAL-001-TRE-1: Primary Frequency Response in the ERCOT Region - Answer To maintain Interconnection steady-state frequency within defined limits. Contingency Reserve Restoration Period - Answer A period not exceeding 90 minutes following the end of the Contingency Event Recovery Period. BAL-001-TRE-1: R1 Primary Frequency Response in the ERCOT Region - Answer R2. The BA shall calculate the Primary Frequency Response of each generating unit/generating facility in accordance with this standard and the Primary Frequency Response Reference Document.1 This calculation shall provide a 12-month rolling average of initial and sustained Primary Frequency Response performance. This calculation shall be completed each month for the preceding 12 calendar months. 2.1. The performance of a combined cycle facility will be determined using an expected performance droop of 5.78%. 2.2. The calculation results shall be submitted to the Compliance Enforcement Authority and made available to the GO by the end of the month in which they were completed. 2.3. If a generating unit/generating facility has not participated in a minimum of (8) eight FMEs in a 12-month period, its performance shall be based on a rolling eight FME average response. [Violation Risk Factor = Lower] [Time Horizon = Operations Assessment] M2. The BA shall have evidence it calculated and reported the rolling average initial and sustained Primary Frequency Response performance of each generating unit/generating facility monthly as required in Requirement R2. BAL-001-TRE-1: R3 Primary Frequency Response in the ERCOT Region - Answer R3. The BA shall determine the Interconnection minimum Frequency Response (IMFR) in December of each year for the following year, and make the IMFR, the methodology for calculation and the criteria for determination of the IMFR publicly available. BAL-002-3: Disturbance Control Standard - Contingency Reserve for Recovery from a Balancing Contingency Event - Answer To ensure the Balancing Authority or Reserve Sharing Group balances resources and demand and returns the Balancing Authority's or Reserve Sharing Group's Area Control Error to defined values (subject to applicable limits) following a Reportable Balancing Contingency Event. BAL-002-3: R1 Disturbance Control Standard - Contingency Reserve for Recovery from a Balancing Contingency Event - Answer R1. The Responsible Entity experiencing a Reportable Balancing Contingency Event shall: [Violation Risk Factor: High] [Time Horizon: Real-time Operations] 1.1. within the Contingency Event Recovery Period, demonstrate recovery by returning its Reporting ACE to at least the recovery value of: zero (if its Pre-Reporting Contingency Event ACE Value was positive or equal to zero); however, any Balancing

Montrer plus Lire moins
Établissement
NERC Standards
Cours
NERC Standards










Oups ! Impossible de charger votre document. Réessayez ou contactez le support.

École, étude et sujet

Établissement
NERC Standards
Cours
NERC Standards

Infos sur le Document

Publié le
11 octobre 2023
Nombre de pages
17
Écrit en
2023/2024
Type
Examen
Contient
Questions et réponses

Sujets

Faites connaissance avec le vendeur

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
Parie Western Governers University
Voir profil
S'abonner Vous devez être connecté afin de suivre les étudiants ou les cours
Vendu
444
Membre depuis
3 année
Nombre de followers
367
Documents
3322
Dernière vente
3 semaines de cela
A+ Score for your exams, cats and assessments. Email if you want your assignments, essays and other school projects done for you at fair and negotiable prices.

100% Money Back Guarantee Immediately available after payment Both online and in PDF No strings attached

3.9

83 revues

5
38
4
18
3
16
2
2
1
9

Récemment consulté par vous

Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Foire aux questions