Questions & Answers Best Rated A+
Steam Using Gravity Displacement: Method of Killing - Exact Answer:
Denatures microorganism proteins
Steam Using Gravity Displacement: Sterilant Used - Exact Answer:
Combination of steam and ambient air
Steam Using Gravity Displacement: How do steam and ambient are
sterilize? - Exact Answer: Steam displaces the air, and forces it out of
the drain vent. Steam then comes in direct contact with items
Steam Using Gravity Displacement: Parameters (3) - Exact Answer: 1.
Time
2. Temperature
3. Pressure
Steam Using Gravity Displacement: Common cycle times (3) - Exact
Answer: 1. 30 min, 250°F, 15 psi
2. 15-25 min, 275°F, 27 psi
3. 10 min, 275°F, 30 psi
,CBSPD Sterilization - Certification Exam Review
Questions & Answers Best Rated A+
Steam Using Gravity Displacement: Items that CAN be sterilized - Exact
Answer: 1. Critical items that are heat and moisture resistant
2. Semi-critical items that are heat and moisture resistant
3. Sharps Containers
Steam Using Gravity Displacement: Items that CANNOT be sterilized -
Exact Answer: Heat and moisture sensitive materials
Steam Using Gravity Displacement: Biological Indicator - Exact Answer:
Geobacillus Stearothermophilus
Steam Using Dynamic Air Removal: Method of Killing - Exact Answer:
Denatures microorganism proteins
Steam Using Dynamic Air Removal: Sterilants Used (3) - Exact Answer:
1. Combination of steam and ambient air
2. Prevacuum Sterilizers
3. (SFPP) Steam-flush pressure-pulse sterilizers
, CBSPD Sterilization - Certification Exam Review
Questions & Answers Best Rated A+
Steam Using Dynamic Air Removal: Parameters (3) - Exact Answer: 1.
Time
2. Temperature
3. Pressure
Steam Using Dynamic Air Removal: Common Cycle Times (2) - Exact
Answer: 1. 4 min, 270°F, 28-30 psi
2. 3 min, 275°F, 28-30 psi
Steam Using Dynamic Air Removal: Items that CAN be sterilized - Exact
Answer: 1. Critical items that are heat and moisture resistant
2. Semi-critical items that are heat and moisture resistant
3. Sharps Containers
Steam Using Dynamic Air Removal: Items that CANNOT be sterilized -
Exact Answer: Heat and moisture sensitive items
Steam Using Dynamic Air Removal: Biological Indicator - Exact Answer:
Geobacillus Stearothermophilus