What are the typical uses of the center port of gauge set? - Answer Used during evacuation, charging and recovery procedures. What color are the gauges on a manifold gauge set? - Answer Low pressure is blue, High pressure is red. What are the typical ranges of pressure measurements used on the gauges of a manifold gauge set? - Answer High side is 0 to 500 PSIG; Low side is 0 to 350 PSIG and 0 to 30 in. Hg below atmospheric pressure. Is the refrigerant leaving a condenser at a high or low pressure? Is it a liquid or a gas? - Answer High pressure, liquid. Is the refrigerant entering the expansion valve (variable metering device) a liquid or gas? - Answer Liquid, high pressure. Is the pressure of the refrigerant entering the compressor high or low? - Answer Low pressure vapor. Where in a refrigerant circuit does a liquid boil to absorb heat? - Answer In the evaporator. The refrigerant in the suction line is a gas that has been heated above its saturation. What is this condition called? - Answer Superheated vapor. What can cause liquid refrigerant to migrate to a compressor crankcase? - Answer If the compressor is located in the coldest location in the circuit. List two conditions that can quickly damage a compressor that is starting to run? - Answer Operating while in a deep vacuum or when the service valves are closed. What system failures require taking an oil sample? - Answer A compressor burnout or if the unit has had a leak. Is flushing with refrigerant an acceptable tube cleaning method? - Answer No. In addition to preventing and repairing leaks what else should a technician do to conserve refrigerant? - Answer Recover and recycle used refrigerants. What factors affect the speed of an evacuation? - Answer Pump size, hose length, hose diameter, size of system to be evacuated, ambient temperature, suction line size, and the amount of moisture in the system. How should gauge set hoses be sized for use in evacuating a system? - Answer Use the shortest length and the largest diameter possible for the quickest evacuation. At least as large as the vacuum pump inlet. When evacuating what is the benefit of using short hoses with large diameters? - Answer Reduces emissions, pressure drop and evacuation time. Which connection determines the preferred size of hoses used with a vacuum pump? - Answer The vacuum pump inlet. As the capacity and suction hose size increase what happens to the time needed for an evacuation? - Answer Time is reduced. What purpose is served by heating a system during dehydration? - Answer To speed up moisture removal. Does a thorough evacuation remove moisture from a system? - Answer Yes. What can happen to oil in the compressor if the moisture is left in an operating system? - Answer The oil will form hydrofluoric and hydrochloric acids which will corrode the internal parts of the system. What is the result of over-evacuating a system? - Answer No damage will be done. How can a system be leak checked using a low pressure gauge? - Answer Vacuum reading will rise when vacuum pump is turned off. How close should the vacuum gauge be connected to the vacuum pump during evacuation? - Answer As far away as possible. When measuring the vacuum of a system being evacuated the system must be isolated. What must be done to the vacuum pump? - Answer Turn it off and valve it off. What is ozone? - Answer 3 atoms of oxygen. It blocks much of the harmful ultraviolet radiation (uv-b) emitted from the sun and it keeps our earth's temperature stable. How much ozone can a chlorine atom destroy in the stratosphere? - Answer One atom can destroy 100,000 ozone molecules. What is Ozone Depletion Potential (ODP)? - Answer The ability of any chemical to deplete the ozone layer. What is CFC? - Answer Chlorofluorocarbon. Which refrigerants are CFC's? - Answer R-11,12,113,114. Which chemical in the CFC refrigerants does the most damage to the ozone layer? - Answer Chlorine. What is an HCFC? - Answer Hydrochlorofluorocarbons. Which refrigerants are HCFC's? - Answer R-22,123. Which is more harmful to the ozone layer a CFC or an HCFC? - Answer CFC's. What is it about CFC's that make them more harmful to the stratosphere? - Answer Chemical strength, they will not breakdown in the lower atmosphere. What is an HFC? - Answer A fluorocarbon that contains no chlorine. Which refrigerants are HFC's? - Answer R-134a,404a,407c,410a. What is the ODP of the HFC refrigerant? - Answer Zero. Which refrigerants contain chlorine? - Answer CFC's and HCFC's. Which refrigerants have high ODP? - Answer CFC's. Which refrigerants have low ODP? - Answer HCFC's, HFC's are zero. What is an azeotrope refrigerant? - Answer A mixture of two or more compounds where the mixture behaves like a single chemical. Is one of the components of R-500 a CFC? - Answer Yes Does stratospheric ozone help or hurt the work of the earth's protective shield? - Answer It helps. What chemical in the stratosphere tells us ozone depletion is occurring? - Answer Chlorine-monoxide. How do we know the chlorine in the stratosphere is coming from CFC's? - Answer The increase in chlorine and fluorine present in the stratosphere, matches the increase in emissions of CFC's. How do we know CFC's get to the stratosphere? - Answer From high altitude air sampling measurements. What role does the ozone layer play in protecting the earth? - Answer It blocks much of the harmful ultraviolet radiation (uv-b). What are the effects on health from increased ultraviolet radiation? - Answer Skin cancer, cataracts, human immunity is reduced. What are the effects on the environment? - Answer Timber growth is reduced, crop yields lowered, marine life and the food chain are impaired. Is ozone depletion a problem for the United States only or a global problem? - Answer A global problem. What is the Montreal Protocol? - Answer A treaty that called for the reduction of production of CFC's. The Montreal Protocol calls for the regulation of what chemicals? - Answer Ozone depleting compounds, CFC's, HCFC's, and Halons. On what date was the production and importation of all CFC's phased out? - Answer In the U.S., after December 31, 1995. Where will we get replacements? - Answer Through recovery of existing refrigerants. What steps are called for by the Clean Air Act? - Answer Taxes on production and use, standards set for the recovery of refrigerants. What is prohibited by the Clean Air Act? - Answer Venting. Do state and local laws have priority over federal law? Can they be less strict? - Answer No. Cities or states can create their own laws but they must be at least as strict as federal laws. To prevent damage to the ozone layer the U.S. is making laws to capture the CFC's now in use. What else does the new law do to restrict the release of CFC's? - Answer Allows states and municipalities to create their own laws to prevent and monitor the release of CFC and HCFC materials into the atmosphere. By recovering refrigerants we ensure adequate supplies and prevent venting. What else does the recovery of refrigerants accomplish? - Answer Prevents stratospheric ozone depletion. The Clean Air Act phases out CFC/HCFC production and prohibits venting. What else does it require? - Answer Standards to be set for recovery of all refrigerants prior to appliance service and disposal. Falsifying or failing to keep required records failing to reach required evacuation levels and knowingly releasing CFC or HCFC refrigerants, are a violations of the Clean Air Act. What activity with a substitute refrigerant is also a violation? - Answer Knowingly venting CFC's, HCFC's and their substitutes. Which refrigerants must be recovered prior to opening a system? - Answer All refrigerants as of . What releases of a CFC and HCFC are violations of the Clean Air Act? - Answer Any knowingly vented refrigerants. On what date did it become illegal to vent CFC and HCFC refrigerants? - Answer July 1, 1992. Which appliances are covered by Section 608? - Answer Any device which contains and uses a class 1 or class 2 substance as a refrigerant and is used for household or commercial purposes. What is the primary reason the EPA requires a service aperture or process stub on all appliances? - Answer For adding or removing refrigerant from the appliance. Who sets the regulations for recovery machines? - Answer EPA. What is a "self-contained" recovery machines? - Answer A recovery machine that has its own compressor to pump refrigerant out of the system. Is HCFC-123 a "low or "high" pressure refrigerant? - Answer Low pressure. Is CFC-12 a "low" or "high" pressure refrigerant? - Answer High pressure. What is the smallest container in which refrigerants may be sold to a Section 608 certified technicians. - Answer 20 pounds. What must you do to the refrigerant in an appliance before disposing of the appliance? - Answer Recover refrigerant or verify that the refrigerant was previously recovered. Who is responsible for removing the refrigerant from household refrigerators prior to disposal? - Answer The final person in the disposal chain. (Scrap metal recyclers, landfill owner, etc) What is the penalty for violation of the Clean Air Act? - Answer Fines up to $27,500 per violation per day and possible loss of technician certification. How much is the bounty for information leading to a conviction? - Answer Up to $10,000. What can happen if a technician cannot demonstrate an ability to use recovery or recycling equipment? - Answer May result in revocation of the technician's certification. What is the name of the process that removes refrigerant from a system and stores it without testing or processing? - Answer Recovery. What is the name for the process that removes moisture and acids from refrigerant but does not test the refrigerant? - Answer Recycling.


Información del documento

Subido en
23 de agosto de 2023
Número de páginas
28
Escrito en
2023/2024
Tipo
Examen
Contiene
Preguntas y respuestas
$12.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Grademasters
3.8
(46)
Vendido
118
Seguidores
69
Artículos
2591
Última venta
1 mes hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes

Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.