CBSPD Sterilization - Certification Exam Review(2023)already passed
CBSPD Sterilization - Certification Exam Review(2023)already passed Steam Using Gravity Displacement: Method of Killing - correct answer Denatures microorganism proteins Steam Using Gravity Displacement: Sterilant Used - correct answer Combination of steam and ambient air Steam Using Gravity Displacement: How do steam and ambient are sterilize? - correct answer Steam displaces the air, and forces it out of the drain vent. Steam then comes in direct contact with items Steam Using Gravity Displacement: Parameters (3) - correct answer 1. Time 2. Temperature 3. Pressure Steam Using Gravity Displacement: Common cycle times (3) - correct answer 1. 30 min, 250°F, 15 psi 2. 15-25 min, 275°F, 27 psi 3. 10 min, 275°F, 30 psi Steam Using Gravity Displacement: Items that CAN be sterilized - correct answer 1. Critical items that are heat and moisture resistant 2. Semi-critical items that are heat and moisture resistant 3. Sharps Containers Steam Using Gravity Displacement: Items that CANNOT be sterilized - correct answer Heat and moisture sensitive materials Steam Using Gravity Displacement: Biological Indicator - correct answer Geobacillus Stearothermophilus Steam Using Dynamic Air Removal: Method of Killing - correct answer Denatures microorganism proteins Steam Using Dynamic Air Removal: Sterilants Used (3) - correct answer 1. Combination of steam and ambient air 2. Prevacuum Sterilizers 3. (SFPP) Steam-flush pressure-pulse sterilizers Steam Using Dynamic Air Removal: Parameters (3) - correct answer 1. Time 2. Temperature 3. Pressure Steam Using Dynamic Air Removal: Common Cycle Times (2) - correct answer 1. 4 min, 270°F, 28-30 psi 2. 3 min, 275°F, 28-30 psi Steam Using Dynamic Air Removal: Items that CAN be sterilized - correct answer 1. Critical items that are heat and moisture resistant 2. Semi-critical items that are heat and moisture resistant 3. Sharps Containers Steam Using Dynamic Air Removal: Items that CANNOT be sterilized - correct answer Heat and moisture sensitive items Steam Using Dynamic Air Removal: Biological Indicator - correct answer Geobacillus Stearothermophilus EO: Method of Killing - correct answer Alkylation: interferes with microorganism metabolism EO: Sterilants Used (2) - correct answer 1. 100% EO (undiluted) - common 2. EO Mixtures (contains HCFC and CO2) - uncommon EO: Parameters (5) - correct answer 1. Time
Escuela, estudio y materia
- Institución
- CBSPD
- Grado
- CBSPD
Información del documento
- Subido en
- 30 de mayo de 2023
- Número de páginas
- 10
- Escrito en
- 2022/2023
- Tipo
- Examen
- Contiene
- Preguntas y respuestas
Temas
-
cbspd sterilization certification exam review2023already passed
-
steam using gravity displacement method of killing denatures microorganism proteins
-
steam using gravity displacement sterilant use
Documento también disponible en un lote