Home Inspector National Exam Prep 2023
Home Inspector National Exam Prep 2023 It is important to maintain a positive grade away from the structure of at LEAST _______ inch drop per foot for six feet. A. 1/4 B. 1/2 C. 3/4 D. 1 - Correct Answer 1 Which of the following BEST describes the report statement shown below? "The roof is in good condition for its age." A. Conclusion B. Recommendation C. Description D. Disclaimer - Correct Answer Conclusion Which of the following conditions would be LEAST critical to your client's safety? A. A pin hole in the heat exchanger B. No handrails on an interior stairway C. Lack of a pressure and temperature relief valve on the water heater D. A non-reversing garage door opener - Correct Answer A pin hole in the heat exchanger The normal MINIMUM run for a residential stair tread is: A. 7 in. B. 8 in. C. 9 in. D. 11 in. - Correct Answer 9 inches Standard three light electrical testers are NOT always reliable because: A. Some receptacles only have two prongs B. Three light testers sometimes have broken bulbs C. Three light testers will not detect multiple wiring problems D. Different test device manufactures have different light patterns - Correct Answer Three light testers will not detect multiple wiring problems Bulging plaster is observed high up on several bedroom walls. The primary concern is the bulging plaster is a(n): A. installation defect B. indication the home was very cold for a period of time C. indication the air handler leaked D. potential safety issue - Correct Answer Potential safety issue EIFS is a siding material that: A. Is used in commercial buildings only. B. Looks like stucco but lacks a wire mesh. C. Can be installed on top of a modified bitumen membrane. D. Can be installed on top of a masonry surface. - Correct Answer Looks like stucco but lacks a wire mesh While inspecting a home, you observe a large ceiling fan with built-in lamps. This installation requires a(an): A. Strong ceiling. B. Pancake junction box. C. Approved brace or box. D. Larger junction box. - Correct Answer Approved brace or box What are the types of heat that must be taken into account when calculating the cooling loads for an HVAC system? a. Sensible and radiant heat b. Radiant and conductive heat c. Conductive and latent heat d. Sensible and latent heat - Correct Answer Sensible and latent heat
Escuela, estudio y materia
- Institución
- National Home Inspector
- Grado
- National Home Inspector
Información del documento
- Subido en
- 19 de mayo de 2023
- Número de páginas
- 14
- Escrito en
- 2022/2023
- Tipo
- Examen
- Contiene
- Preguntas y respuestas
Temas
-
it is important to maintain a positive grade away from the structure of at least inch drop per foot for six feet a 14 b 12 c 34 d 1
-
which of the following best describes the report sta
Documento también disponible en un lote