Answers (Grade A+)
Question 1: Overhand Knot
Answer: Another term for a safety knot is a
Question 2: What is the first step in developing any fire attack plan?
Answer: Conducting an accurate size up
Question 3: The process of erecting materials such as wood panels, timber, or jacks to strengthen a
wall or prevent further collapse is known as:
Answer: shoring
Question 4: Which is true regarding the physical limits of wearing a SCBA?
Answer: Firefighters consume air at different rates based on their aerobic fitness
Question 5: When using pneumatic airbags to perform a lift, one should never stack more than
______ bags
Answer: Two
Question 6: Which forcible entry tool would typically be used to extend a firefighters reach while
sweeping across floors and under furniture
Answer: Flat head axe
Question 7: Both firefighters face the same direction
Answer: In the extremity carry
Question 8: Location
Answer: In the term LUNAR, the L stands for
Question 9: Which are characteristics of a primary search?
Answer: Rapid and systematic
Question 10: What exception is there to the two in/two out rule?
Answer: Imminent life threatening situation where immediate action can save life
Page 1
,Question 11: What part of the rope is used to tie knot/hitch End of the rope that is used to tie a knot
is called the
Answer: Working End
Question 12: The mind set of children leads them to:
Answer: Hide from danger in toy boxes, closets, and under beds
Question 13: The area immediately around the fire, and the rest of the fire floor, then the area
directly above the fire in the rest of the floor, then all higher level floors, from top floor down, to the
areas below the fire floor
Answer: Coordination of a search for victims in a multi story structure fire is based on a system of priorities.
Which is the correct listing of priorities from first to last
Question 14: Target Hazard
Answer: A facility in which there is a high potential for life or property loss from a fire is called a ______
hazard
Question 15: What generally requires the use of a tag line when it is being hoisted up to the roof of a
structure?
Answer: Smoke Ejector
Question 16: What is one item that would be included in a life safety ropes record?
Answer: Each time it was used
Question 17: Which of the following knots is not regarded as suitable for use in anchoring a
life-safety rope and its principal use is to attach a rope to an object such as a pole, post, or hoseline?
Answer: Single/double overhand safety knot
Question 18: Remove toilets and use the sewer system as a drain
Answer: If large amounts of water need to be removed from areas lacking of drains, firefighters may point to
remove the water quickly
Question 19: What is the best way to extinguish a smoldering mattress? A. Take it outside and soak
it B. Open the mattress and thoroughly wet the smoldering area C. Place it flat on the floor and soak
it D. Apply Class A foam to the smoldering area
Answer: A. Take it outside and soak it
Page 2
, Question 20: D. Wait for investigators to examine it
Answer:
- If overhaul operations may disturb possible evidence, what should fire fighters do before continuing with
their work? A. Have a law enforcement officer evaluate the situation B. Take photos or make sketches of the
evidence in an undisturbed state
C. Tag and bag the evidence D. Wait for investigators to examine it
Question 21: Life safety and utility
Answer: Fire service rope falls into to use classifications
Question 22: Which knot is used to prevent the end of a rope from slipping through the primary
knot
Answer: Safety
Question 23: Resourced needed
Answer: In the term LUNAR, the R stands for
Question 24: drafting hydrants
Answer: Dry hydrants, also called____________, provide quick and reliable access to static water sources.
Question 25: What should be in place during overhaul
Answer: Charged Hose Line
Question 26: 1000 gpm or greater
Answer: Sprinkler fire department connections should be supplied with water from pumpers that has a capacity
of at least _______________ gpm
Question 27: 5
Answer: Carbon composite cylinders must be hydrostatically tested every ____years.
Question 28: 90
Answer: If apparatus sirens and noise levels exceed ____ decibels, firefighters should wear hearing protection
Question 29: In high rise firefighting situations, typically the fire attack will be initiated from:
Answer: One floor below the fire
Question 30: Knee Press
Answer: A firefighter without a spanner wrench can usually break a tight coupling if the ____ method is used.
Page 3