FLUOROSCOPY ACTUAL TEST PAPER
QUESTIONS WITH SOLUTIONS GRADED
A
◉ If X-ray source is below the table, useful beam exposure must be
measured at what distance above the table top. Answer: 30 cm


◉ Table top exposure rates for units without auto exposure control
must be measured every. Answer: 3 years


◉ Dark adaptation for the eye takes how long. Answer: 30 minutes


◉ Target-to-tabletop distance must be greater than and should be
greater than.... Answer: 12 and 18 inches


◉ Integration time for brain to recognize an object. Answer: 0.2
seconds


◉ Most scatter occurs at which direction from the primary beam.
Answer: 135 degrees


◉ mA setting for spot filming where a spot film camera is not used.
Answer: 150 mA

,◉ Greatest dose to the patient comes from spot filming cameras
using this film size. Answer: 105 mm


◉ SI unit analogous to the rad is. Answer: Gray


◉ _________ is a variation in density resulting from the random spatial
distribution of quanta.. Answer: Quantum sink


◉ SI unit analogous to the rem. Answer: Sievert (unit)


◉ Exposure reduction of .25 mm lead. Answer: 97%


◉ Scattered radiation received is proportional to. Answer: Dose
received by the patient


◉ Most effective medium for static viewing in terms of reducing
patient dose. Answer: Video disc recorder


◉ Contrast of the image intensifying tube is measured by. Answer:
conversion factor


◉ maximum magnification for cinefluorography is done via which
method. Answer: total over framing

, ◉ Ratio of photons that leave the output phosphor to the number of
Xray photons that strike the input phosphor. Answer: Flux gain


◉ Half value layer determines which characteristic of the Xray.
Answer: Xray quality


◉ Ability to distinguish separate objects in line pairs per mm.
Answer: Resolving power


◉ The portion of the image intensifier responsible for magnification.
Answer: electrostatic lenses


◉ resolution of a 9 inch image intensifier tube. Answer: 3.5 line
pairs per millimeter


◉ light photons intercepting when electrons strike a fluorescent
screen forms a.... Answer: Real image


◉ Fluoro with a grid in place affects exposure rates how. Answer:
1.5-2 x higher


◉ Greatest radiosensitivity of fetus occurs when. Answer: 2-8 weeks
gestation

Información del documento

Subido en
22 de octubre de 2026
Número de páginas
22
Escrito en
2026/2027
Tipo
Examen
Contiene
Preguntas y respuestas
$17.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Vendido
3
Seguidores
0
Artículos
6401
Última venta
5 días hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes