FDNY S 92 EXAM STUDY GUIDE
WITH TESTED SOLUTIONS

⫸ What types of fuel require an FDNY permit for portable space
heaters? Answer: Combustible liquids, compressed natural gas (CNG),
liquefied petroleum gas (LPG), and piped natural gas (except in Group
R-3 occupancies).


⫸ Who must supervise the handling and use of portable fueled space
heaters at construction sites? Answer: A person holding an S-92
certificate of fitness.


⫸ What is the role of the Construction Site Fire Safety Manager
(CSFSM) regarding portable space heaters? Answer: Ensure valid
FDNY permits are issued, the S-92 Certificate of Fitness holder is
present, and all applicable standards and rules are complied with.


⫸ What is required for the storage of LPG/CNG containers? Answer: It
must be under the general supervision of a W-44/G-44 Certificate of
Fitness holder.


⫸ What is the required clearance from combustibles for portable fueled
space heaters? Answer: At least 5 feet from any building, combustible
decorations, exits, and similar combustible attachments.

, ⫸ What must be done before refueling portable fueled space heaters?
Answer: They must be shut down and cooled to the touch.


⫸ What is an escape hatch in the context of using portable fuel-fired
heaters during concrete placement? Answer: An escape hatch extending
from the floor where concrete is placed to at least one story below,
located near the center of the building.


⫸ What is the exception to the requirement for an escape hatch during
concrete placement? Answer: An escape hatch is not required if at least
one permanent stairway is available and enclosed with a fire-rated
enclosure.


⫸ What are the specifications for ladders in the escape hatch? Answer:
At least two fixed, vertical ladders enclosed in a metal shield, extending
from 3 feet above the floor to at least two stories below or to the ground
floor.


⫸ What materials are required for decking over the shield space in the
escape hatch? Answer: 2-inch or heavier planking covered with plywood
or sheet metal to make the decking smoke tight.


⫸ When can portable oil-fueled space heaters be used at construction
sites? Answer: During the heating season from October 15 to May 30,
and at other times as authorized by permit.

Información del documento

Subido en
15 de octubre de 2026
Número de páginas
7
Escrito en
2026/2027
Tipo
Examen
Contiene
Preguntas y respuestas
$17.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Vendido
4
Seguidores
0
Artículos
8090
Última venta
1 semana hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes