• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 4 fuera de 31 páginas
Examen

Ardms Spi Study Guide Questions And Answers Already Passed Latest Update 100 Correct Answers

Document preview thumbnail
Vista previa 4 fuera de 31 páginas

ARDMS SPI Exam Study Guide and Reference Material | Expert-Verified Solutions In soft tissue, if the frequency of a wave is increased the Propagation Speed (PS) will... - answer - Remain the Same because stiffness and density affect Propagation Speed. What is the audible range? - answer - 20-20,000Hz 20,000Hz=Ultrasound Frequency is measured in - answer - Hertz (Hz) is Cycles per Second Not affected by sonographer Increase Frequency; Decrease Depth A period is the length of time it takes for - answer - one complete wavelength to pass a fixed point PRP is determined by - answer - Transmit time and receive time. Period is measured in - answer - Time (μs) When the sonographer changes the imaging depth what parameters are changed? - answer - PRP, PRF, Duty Factor What is duty factor? - answer - The percentage or fraction of time that the system is transmitting a pulse (Time Sound is ON or ON-Time). Propagation Speed in SOFT TISSUE - answer - 1.54 mm/μs (1540 m/sec) Unit of measurement for Pulse Duration, Duty Factor, PRP, and Period - answer - Time, (μs) Pulse duration is determined by - answer - Sound Source Only Pulse Duration is controlled by - answer - the ultrasound system and transducer Pulse Duration Formula - answer - pulse duration (μs) = # cycles in pulse/frequency(MHz) PD= Number of cycles in Pulse/ Frequency(Hz) Spatial Pulse Length (SPL) (measurement) - answer - The distance that a pulse occupies in space from the start to the end of a pulse. (mm) Typical values for spatial pulse length in soft tissue. - answer - 0.1 to 1.0 mm Spatial pulse length is determined by - answer - sound source and medium Spatial Pulse Length is directly proportional to - answer - the Number of Cycles in the Pulse and the Wavelength (Directly Proportional means that increased SPL will increase both the number of cycles in the pulse and the wavelength if increased). Spatial pulse length is inversely proportional to - answer - Frequency (MHz) (Inversely Proportional means that increased SPL will lower frequency. This is because axial resolution is better with lower frequency) Pulse Duration (PD) - answer - The actual time from the start of a pulse to the end of that pulse; a single transmit, talking, or "on" time. Time the pulse is on typically measured in (ms). Pulse Length - answer - The distance of the pulse start to end or the duration or length of a single pulse Pulse Length is typically measured in (mm). the ability of an object to resist compression and relates to the hardness of a medium? - answer - Stiffness. Think: ↑ Stiffness ↑ Speed ↓ Density ↑ Speed An increase in pulse repetition frequency would lead to: - answer - Increasing pulse repetition frequency, increases duty factor. ↑ PRF ↑ Duty Factor Which of the following would have the highest propagation speed? - answer - Bone has the highest propagation speed, at m/s. What has the lowest propagation speed? - answer - air technically has the lowest propagation speed at 300 m/s Which has the Slowest Propagation Speed? Water Soft Tissue Bone Lung tissue - answer - Lung Tissue As imaging depth increases, the pulse repetition frequency (PRF) must: - answer - Decrease As imaging depth increase, pulse repeition freqency (PRF) decreases. ↑ Imaging Depth ↓ PRF What describes the amount of refraction that occurs at an interface? - answer - Snell's law Refraction: the redirection of the transmitted sound beam Snell's law describes the angle of transmission at an interface based on the angle of incidence and the propagation speeds of the two media. Pressure is typically expressed in: - answer - Pascals (Pa) The typical range of frequency for diagnostic ultrasound imaging is - answer - 1-20 Mhz is the typical range of frequency for diagnostic ultrasound imaging. The attentuation coefficient in soft tissue is equal to: - answer - Attentuat


Información del documento

Subido en
15 de octubre de 2026
Número de páginas
31
Escrito en
2026/2027
Tipo
Examen
Contiene
Preguntas y respuestas
$15.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
SARAHnkalu
4.6
(7)
Vendido
41
Seguidores
0
Artículos
3917
Última venta
4 días hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes

Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.