API 653 RECERTIFICATION QUIZ Questions with Correct Solutions Question: 1. Per API 653 , with of the following is required when converting an existing tank to operation at elevated temperatures when it was not originally designed and constructed to API 650, Appendix M? Answer: The Shell to bottom joint shall be evaluated for fatigue Question: 2. When removing an existing tank bottom, all arc-gouged areas of the tank shell-to-bottom shall be: Answer: examined using magnetic particle inspection, and defective areas repaired and re-examined. Question: 3. If RBI assessment has been conducted and the tank has cathodic protection plus a thin-film lining, the maximum inspection interval is:

Vista previa del contenido

API 653 RECERTIFICATION QUIZ Questions with Correct Solutions


Question:
1. Per API 653 , with of the following is required when converting an existing tank to
operation at elevated temperatures when it was not originally designed and constructed to
API 650, Appendix M?

Answer:
The Shell to bottom joint shall be evaluated for fatigue


Question:
2. When removing an existing tank bottom, all arc-gouged areas of the tank shell-to-bottom
shall be:

Answer:
examined using magnetic particle inspection, and defective areas repaired and re-examined.


Question:
3. If RBI assessment has been conducted and the tank has cathodic protection plus a thin-film
lining, the maximum inspection interval is:

Answer:
14 years


Question:
4. When installing a new nozzle in a tank of unknow material, what stress value should be
used to calculate the required shell thickness and reinforcement?

Answer:
20,000 lbf/in2


Question:
5. In regards to underside corrosion on tank bottoms, the corrosion rate of steel in a wet
environment.

Answer:
may double with every 18 °F increase in temperature above 77 °F.


Question:
6. Grade 350W/50W is acceptable for tank plate to a maximum thickness of:

Answer:
45mm (1.75in) if fully killed and made to a fine grain practice.

, Question:
7. If an RBI assessment has been conducted and the tank has a release prevention barrier,
the maximum initial inspection interval is:

Answer:
25 years


Question:
8. As an alternative to the procedures in API 653 for the evaluation of any thinning of the tank
shell below minimum required wall thickness may be evaluated for continued service using
which code?

Answer:
API RP 579, section 4, 5 or 6.


Question:
9. When welding on a tank shell constructed of Group I steel that is greater than 1.5 inches
thick below what minimum metal temperature ?preheat?

Answer:
200°F


Question:
10. When evaluated an existing temperature services tank, which has a successful service
history of operation but was not originally designed and constructed to the requirement of
API 650, appendix M, which condition temperature has to be used?

Answer:
The max Operating Temperature shall not exceed the temperature at which the tank has
successfully operated in the pass.


Question:
11. Flange material used for tank repair and alteration shall meet the minimum requirements
for the material specifications according to:

Answer:
The as built standard


Question:
12. which is an advantage of thick film UN-REIN- FORCED linings ?

Answer:
Fast curing and can be put back in service after 24 hours at normal ambient temperature.

Información del documento

Subido en
13 de octubre de 2026
Número de páginas
6
Escrito en
2026/2027
Tipo
Examen
Contiene
Preguntas y respuestas
$8.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
VictorGrades
5.0
(1)
Vendido
25
Seguidores
0
Artículos
2765
Última venta
1 semana hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes